The human kidney is one of the most important organs in the human body; it performs many functions
and has a great impact on the work of the rest of the organs. Among the most important possible treatments is
dialysis, which works as an external artificial kidney, and several studies have worked to enhance the
mechanism of dialysate flow and improve the permeability of its membrane. This study introduces a new
numerical model based on previous research discussing the variations in the concentrations of sodium,
potassium, and urea in the extracellular area in the blood during hemodialysis. We simulated the differential
equations related to mass transfer diffusion and we developed the model in MATLAB Simulink environment.
A value of 700 was appeared to be the most appropriate as a mass transfer coefficient leading to the best
permeability. The suggested models enabled to track the temporal variations of urine, K and Na concentrations
in blood streamline. This also produced the time needed to reach the requested concentrations mentioned in
literature studies (960 ms). Concentrations evaluation was performed with error rates not exceeding 2% for all
ions compared to the normal values of human blood.The current work presents the first step towards combinig
the mass transfer and diffusion principles with our efforts in designing and implementing an electrophoresisbased implantable kidney.
Copper selenide (Cu2Se) thin films were prepared by thermal evaporation at RT with thickness 500 nm. The heat-treating for (400 &500) K for the absorber layer has been investigated. This research includes, studying the structural properties of X-ray diffraction (XRD) that show the Cu2Se thin film (Cubic) and has a polycrystalline orientation prevalent (220). Moreover, studying the effect of annealing on their surface morphology properties by using Atomic Force Microscopy AFM. Optical properties were considered using the transmittance and absorbance spectra had been recorded when wavelength range (400 - 1000) nm in order to study the absorption coefficient and energy gap. It was found that these films had allowed direct transitio
... Show MoreChronic renal failure (CRF) affects thyroid function in multiple ways, including low circulating thyroid hormone concentration, altered peripheral hormone metabolism, disturbed binding to carrier proteins, possible reduction in tissue thyroid hormone content, and increased iodine store in thyroid glands.The target of study is to find a relationship between chronic renal failure and thyroid function.In addition, we tried to study the effect of CRF on serum creatinine dependent on the level of thyroid hormones (T3 and T4) and thyroid stimulating hormones(TSH). Forty patients with chronic renal failure (20 male, 20 female) were enrolled in this study in addition to forty healthy individual as control gro
... Show MoreBackground: Although the issue of anemia after renal transplantation (RT) has received increasing attention lately, the data on the exact prevalence of post-transplantation anemia (PTA) in the Iraqi patients are limited. Objective: In this study we sought to determine the prevalence of PTA among Iraqi patients and to correlate the renal allograft function measurements and the use of immunosuppressant with the prevalence of anemia. Patients and Methods: One hundred and twelve (74 male, 38 female) kidney transplant recipients (KTR) attending the kidney transplant center at surgical specialties hospital were studied. All patients were on maintenance, combined immunosuppressive therapy. The renal function tests [blood urea, serum cre
... Show MoreAbstract: Coriandrum sativum leaves are used in folk medicine to treat several diseases such as digestive system disorder, diabetes, and hyperlipidemia. This study was designed to investigate the effect of aqueous extract of Coriandrum sativum on the structure and function of kidney, 30 males of white Swiss mice Mus musculus were divided randomly to three groups with 10 mice in each group. Animals of first group (control group) had been given orally 0.1 ml of tap water, animals in the second group had been treated orally with 0.1 of single dose (125 mg/Kg b. w./day) of C. sativum leaves extract and animals in the third group has been treated orally with 0.1 ml (250mg/Kg. b. w./day) of the same extract for 30 days. At the end of experiment,
... Show MoreBackground: Patients requiring renal biopsies have various glomerular diseases according to their demographic characteristics.
Objective: To study types of glomerular disease among adult Iraqi patients in a single center in Baghdad/Iraq
Material and Methods: A total of 120 native kidney biopsies were studied. All biopsies were adequate and were processed for Light Microscopy.
The age range of the study patients was 17-67 years, with a mean of 38.5 years. The mean follow up period was 28 weeks (4-52 weeks)
Indication for biopsy included: Nephrotic syndrome (N=72; 60%), Asymptomatic proteinuria (N=21; 17.5%), acute nephritic presentation (N=17; 14.16%), asymptomatic haematuria (N=10; 8.33%).
Results: Primary glomerulonephrit
Renal function tests are commonly used in clinical practice to look for renal disease, the most common includes the serum urea, uric acid and creatinine. Heart failure patients have a higher incidence of renal function test abnormalities than individuals who do not have heart failure disease. Fifty subjects of adults (male) were divided in to two groups, 25 subjects (healthy) as control (group1) and 25 subjects with heart failure (group 2). Our results indicate that serum uric acid, urea, and creatinine values were significantly elevated (P≤0.05) in patients group (2) compared with healthy group (1). The results also showed, the effect of age categories on uric acid blood urea nitrogen and creatinine values (P≤0.05) and there were no si
... Show MoreThe present work aims to validate the experimental results of a new test rig built from scratch to evaluate the thermal behavior of the brake system with the numerical results of the transient thermal problem. The work was divided into two parts; in the first part, a three-dimensional finite-element solution of the transient thermal problem using a new developed 3D model of the brake system for the selected vehicle is SAIPA 131, while in the second part, the experimental test rig was built to achieve the necessary tests to find the temperature distribution during the braking process of the brake system. We obtained high agreement between the results of the new test rig with the numerical results based on the developed model of the brake
... Show MoreCoaxial (wire-cylinder) electrodes arrangements are widely used for electrostatic deposition of dust particles in flue gases, when a high voltage is applied to electrodes immersed in air and provide a strongly non-uniform electric field. The efficiency of electrostatic filters mainly depends on the value of the applied voltage and the distribution of the electric field. In this work, a two-dimensional computer simulation was constructed to study the effect of different applied voltages (20, 22, 25, 26, 28, 30 kV) on the inner electrode and their effect on the efficiency of the electrostatic precipitator. Finite Element Method (FEM) and COMSOL Multiphysics software were used to simulate the cross section of a wire cylinder. The results sh
... Show MoreBackground : The kidneys may be injured in abdominal trauma, both blunt & penetrating. Renal trauma may manifest in a dramatic fashion for both the patient and the clinician. Objectives: To evaluate the incidence, management, morbidity &mortality of renal injury in blunt & penetrating abdominal trauma.
Results:The majority o f patients were males (35= 77.8%), the rest were females (10= 22.2%). The average age was 37 years (range= 18-56 years). The most common grades were grade1, grade2 and grade3 (40=88.9%), while 5 patients (11.1%) were grades 4 and 5.The most common associated injuries were liver, spleen, small & large bowels and diaphragm. The mortality was 20% (9 patients). The most common cause of death was multip
This research was conducted to study the feasibility of using fruit peels as biosorbent for removal of Pb+2, Cu+2 and Zn+2 ions from simulated wastewater. A waste biomass of Pomegranate Peel or Punicagranatum L. (P. granatum L.) was chosen as neutral biosorbent in this study.Fourier transformation infrared (FTIR) was used to characterize the surface of PGP, the results confirm that amino, carboxylic, hydroxyl and carbonyl group on the surface of PGP. Different parameters such as initial concentration range between (25-200) mg/L, pH (3-7), contact time (1-2) hour, amount of sorbent (0.1- 4) gm, agitation speed range (200- 500) rpm and temperature (25- 50oC), influencing the sorp
... Show More