Preferred Language
Articles
/
bsj-6686
Spectrophotometric Analysis of Vancomycin Hydrochloride in Pure and Pharmaceutical Injections via Batch and Cloud Point Extraction Techniques
...Show More Authors

Development of a precise and delicate reaction has been acquired for the determination of vancomycin hydrochloride using batch and cloud point extraction (CPE) methods. The first method is based on the formation of azo dye as a result of diazotized dapsone coupled with vancomycin HCl (VAN) in a basic medium. The sensitivity of this reaction was enhanced by utilizing a nonionic surfactant (Triton X-114) and the cloud point extraction technique (second method). The azo dye formed was extracted into the surfactant-rich phase, dissolved in ethanol and detected at λmax 440 nm spectrophotometrically. The reaction was investigated using both batch and CPE methods (with and without extraction), and a simple comparison between the two developed methods was made. The conditions that affect the extraction process and the sensitivity of the methods have been carefully examined. The linearity of the calibration curves was in the range of 3-50 and 0.5- 25 µg.mL-1 with limits of detection of 0.806 and 0.462 µg.mL-1 for VAN in both batch and CPE procedures, respectively. The percentage of relative standard deviation (R.S.D.%) for the two methods was better than 2.54% and 2.83%, respectively. The recommended procedures have been effectively used to assay VAN in commercial injections.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 06 2022
Journal Name
Methods And Objects Of Chemical Analysis
Spectrophotometric Analysis of Quaternary Drug Mixtures using Artificial Neural network model
...Show More Authors

A Novel artificial neural network (ANN) model was constructed for calibration of a multivariate model for simultaneously quantitative analysis of the quaternary mixture composed of carbamazepine, carvedilol, diazepam, and furosemide. An eighty-four mixing formula where prepared and analyzed spectrophotometrically. Each analyte was formulated in six samples at different concentrations thus twenty four samples for the four analytes were tested. A neural network of 10 hidden neurons was capable to fit data 100%. The suggested model can be applied for the quantitative chemical analysis for the proposed quaternary mixture.

Scopus (2)
Scopus
Publication Date
Fri Apr 25 2025
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences (ihjpas)
Spectrophotometric Investigations for Simultaneous Analysis of Certain Antibacterial: A Brief Review
...Show More Authors

Antibacterial substances belong to a group of compounds that attack dangerous microorganisms. Therefore, killing bacteria or reducing their metabolic activity will lessen their adverse effects on a biological system. They originated from either synthetic materials, microbes, or mold. Many of these medications treat the gram-negative bacteria from the critical precedence group, such as pseudomonas, carbapenem-resistant acinetobacter, and enterobacterales. This study aims to investigate the simultaneous analysis of specific antibacterial spectrophotometrically. The WHO maintains this list of priority infections with antibiotic resistance. Drug combinations in single dosage forms are becoming increasingly popular in the pharmaceutical industry

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
Methods And Objects Of Chemical Analysis
Spectrophotometric Analysis of Quaternary Drug Mixtures using Artificial Neural network model
...Show More Authors

A Novel artificial neural network (ANN) model was constructed for calibration of a multivariate model for simultaneously quantitative analysis of the quaternary mixture composed of carbamazepine, carvedilol, diazepam, and furosemide. An eighty-four mixing formula where prepared and analyzed spectrophotometrically. Each analyte was formulated in six samples at different concentrations thus twentyfour samples for the four analytes were tested. A neural network of 10 hidden neurons was capable to fit data 100%. The suggested model can be applied for the quantitative chemical analysis for the proposed quaternary mixture.

View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Method Combined with HPLC for Bisphenol F Determination in Plastic Bottled Water and Thermal Paper
...Show More Authors

Based on the diazotization-coupling reaction, a new, simple, and sensitive spectrophotometric method for determining of a trace amount of (BPF) is presented in this paper. Diazotized metoclopramide reagent react with bisphenol F produces an orange azo-compound with a maximum absorbance at 461 nm in alkaline solution. The experimental parameters were optimized such as type of alkaline medium, concentration of NaOH, diazotized metoclopramide amount, order additions, reaction time, temperature, and effect of organic solvents to achieve the optimal performance for the proposed method. The absorbance increased linearly with increasing bisphenol F concentration in the range of 0.5-10 μg mL-1 under ideal conditions, with a correlati

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Southwest Jiaotong University
Integrity and Security in Cloud Computing Environment: A Review
...Show More Authors

Cloud computing is a newly developed concept that aims to provide computing resources in the most effective and economical manner. The fundamental idea of cloud computing is to share computing resources among a user group. Cloud computing security is a collection of control-based techniques and strategies that intends to comply with regulatory compliance rules and protect cloud computing-related information, data apps, and infrastructure. On the other hand, data integrity is a guarantee that the digital data are not corrupted, and that only those authorized people can access or modify them (i.e., maintain data consistency, accuracy, and confidence). This review presents an overview of cloud computing concepts, its importance in many

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of Methyl Green Dye onto Bamboo in Batch and Continuous System
...Show More Authors

Adsorption techniques are widely used to remove certain classes of pollutants from waters, especially those that are not easily biodegradable. Dyes represent one of the problematic groups. The removal of methyl green from waste water using bamboo was studied in batch and continuous system. In batch system equilibrium time and adsorption isotherm was studied at different concentrations (5, 10, 15, 20, 25 and 30 ppm) and 50 mg weight of adsorbent.
Langmuir and Freundlich equations were applied for adsorption isotherm data. Langmiur equation was fitted better than Freundlich equation (R2=0.984 for Langmuir equation).The maximum percentage dye removal obtained 79.4% and adsorption capacity was 15.5 mg/g. For continuous system the breakthr

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2024
Journal Name
International Communications In Heat And Mass Transfer
Accelerated charging of PCM in coil heat exchangers via central return tube and inlet positioning: A 3D analysis
...Show More Authors

View Publication
Scopus (41)
Crossref (39)
Scopus Crossref
Publication Date
Tue May 20 2025
Journal Name
Vrsacin Deae-cellulose Linezolid Neutrophils Inflammation
Antibacterial and therapeutic effects of vancomycin-resistant Staphylococcus aureus bacteriocin (VRSAcin) in the treatment of VRSA skin infection in mice
...Show More Authors

Vancomycin Staphylococcus aureus (VRSA) is a strain of S. aureus that is considered the main cause of bacterial skin and soft tissue infections. It has acquired resistance to vancomycin and represents a therapeutic challenge. The current study aimed to compare the possible therapeutic effects of VRSA bacteriocin (VRSAcin) on the treatment of skin infection in mice with those of an antibiotic (linezolid). The results showed that of the fifty swabs obtained from human skin wounds. One isolate was selected for VRSAcin extraction depending on its antibiotic resistance using an antibiotic susceptibility test.An agar well diffusion test was used to determine bacteriocin’s antibacterial activity, as well as its a minimum inhibitory concentration

... Show More
Preview PDF
Publication Date
Fri May 17 2013
Journal Name
Sensors
Evolution of Electroencephalogram Signal Analysis Techniques during Anesthesia
...Show More Authors

Biosignal analysis is one of the most important topics that researchers have tried to develop during the last century to understand numerous human diseases. Electroencephalograms (EEGs) are one of the techniques which provides an electrical representation of biosignals that reflect changes in the activity of the human brain. Monitoring the levels of anesthesia is a very important subject, which has been proposed to avoid both patient awareness caused by inadequate dosage of anesthetic drugs and excessive use of anesthesia during surgery. This article reviews the bases of these techniques and their development within the last decades and provides a synopsis of the relevant methodologies and algorithms that are used to analyze EEG sig

... Show More
View Publication
Scopus (62)
Crossref (63)
Scopus Clarivate Crossref
Publication Date
Sat Jul 18 2026
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication