Preferred Language
Articles
/
bsj-6405
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at threshold 10%. The DD/DTA criteria are performed with 3%/3 mm and 2%/2 mm. A significant difference is shown between the measured and calculated point dose for the treatment plans. A comparison made between the gamma passing rate between the 2%/2 mm and 3%/3 mm shows a significant difference for local and global which shows that the 2%/2 mm are more sensitive to dose variation than 3%/3 mm. The total monitor unit (MU) shows a negative linear relationship with both criteria and %GP types. A significant correlation is shown between the total MU and global %GP at 2%/2 mm criterion. The conclusion of the study indicates that 2%/2 mm criterion is more sensitive to the dose distribution changes than the 3%/3 mm. The total number of monitor units should be taken into consideration during the planning of H&N tumors using the IMRT plans.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 02 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability
Effect of thickness variation CdO/PSi thin films on detection of radiation
...Show More Authors

CdO films were deposited on substrates from glass, Silicon and Porous silicon by thermal chemical spray pyrolysis technique with different thicknesses (130 and 438.46) nm. Measurements of X-ray diffraction of CdO thin film proved that the structure of the Polycrystalline is cubic lattice, and its crystallite size is located within nano scale range where the perfect orientation is (200). The results show that the surface’s roughness and the root mean square increased with increasing the thickness of prepared films. The UV-Visible measurements show that the CdO films with different thicknesses possess an allowed direct transition with band gap (4) eV. AFM measurement revealed that the silicon porosity located in nano range. Cadmium oxide f

... Show More
Scopus (2)
Scopus
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Dentistry
New functional and aesthetic composite materials used as an alternative to traditional post materials for the restoration of endodontically treated teeth
...Show More Authors

Objectives To tailor composites of polyethylene–hydroxyapatite to function as a new intracanal post for the restoration of endodontically treated teeth (ETT). Methods Silanated hydroxyapatite (HA) and zirconium dioxide (ZrO2) filled low-density polyethylene (LDPE) composites were fabricated by a melt extrusion process and characterised using infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The flexural strength and modulus were determined in dry state and post ageing in simulated body fluid and fractured surfaces analysed by SEM. The water uptake and radiographic appearance of the experimental composites were also measured and compared with a commercially known endodontic fibre

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Mon Jul 30 2018
Journal Name
Journal Of Pharmacy And Biological Sciences
Histological study of the embryogenesis of metencephalon in pre-implantation of albino rat's embryos after maternal treated with silver nanoparticles
...Show More Authors

Cerebellum is the most important and critical part of the central nervous system, cerebellum is very sensitive to the abnormal changes during the embryological development in its histological structure, the exposure to any infection during embryogenesis produce abnormalities in the cerebellum and behavioral of offspring. In this study we tried to study the ontogenesis of the cerebellum in the embryos of the albino rats and detection the effect of the AgNPs on the ontogenesis of the rat cerebellum after exposure of AgNPs during pregnancy. we used 60 female pregnant rats divided in to three group, each contain 20 female, (G1) treated with 2mg/kg /day suspension of silver nanoparticles (Ag NPs) (G2) treated with 20mg/kg/day AgNPs from first da

... Show More
Preview PDF
Publication Date
Sat Sep 01 2007
Journal Name
Saudi Medical Journal
Topical zinc sulphate solution for treatment of viral warts.
...Show More Authors

KE Sharquie, AA Khorsheed, AA Al-Nuaimy, Saudi Medical Journal, 2007 - Cited by 91

View Publication
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Heterogeneous Photocatalytic Degradation for Treatment of Oil from Wastewater
...Show More Authors

In the present study, advanced oxidation process / heterogeneous photocatalytic process (UV/TiO2/Fenton) system was investigated to the treatment of oily wastewater. The present study was conducted to evaluate the effect of hydrogen peroxide concentration H2O2, initial amount of the iron catalyst Fe+2, pH, temperature, amount of TiO2 and the concentration of oil in the wastewater.  The removal efficiency for the system UV/TiO2/Fenton at optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=5, temperature =30oC, TiO2=75mg/L) for 1000mg/L load was found to be 77%.

Aluminum foil cover around the re

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Scholars' Press
Determination of Pollutants in Water Treatment for Petroleum Refinery
...Show More Authors

Dora petroleum refinery waste water is the one of the important source of pollution by priority pollutant aromatic compound discharged to Tigris river in Iraq. the station has waste water treatment unit contains many treatment subunits The most important sub units is :skimmer units ,physiochemical unit ,daf unit, biological unit. The aim of research project is to study the ability of unit to remove the priority pollutant aromatic compound and follow up these compounds in river to study ability of river to self removal. A solid phase extraction (SPE) followed by high performance liquid chromatography-ultra violet (HPLC-UV) technique is depicted for the quantitative estimation of benzidines and phenols. Experimental studies were performed to

... Show More
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Study of Electrodialysis for Treatment Fuel Washing Wastewater
...Show More Authors

In this work, electrodialysis (ED) has been demonstrated to be appropriate technique for reducing the electrical conductivity of real wastewater from fuel washing unit, which has been previously treated by other electrochemical technology (electrocoagulation and electrooxidation).  A five cell electrodialysis stack, with an active membrane area of 60 cm2 per cell was employed. During a batch recirculation mode ED system, the effects of parameters such as electrical potential applied (6-18 V) and flow rate of streams (0.5-1.7 L/min.) on the performance of the total dissolved solids (TDS) separation and specific power consumption (SPC) were studied. The results indicate that the process of ED under potential (15 V) and flow

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Electrical stimulation for the treatment of Knee joint osteoarthritis
...Show More Authors

Abstract 20 patients with osteoarthritis of the knee joint were treated by electrical stimulation in the form of 6 sessions every other day each sessions of diphase fixe (DF) for 4 minutes followed by rest for 4 minutes then treated with a monophase fixe (MF) for 2 minutes. By clinical & statistical analysis ( P value < 0.05) we conclude that the electrical stimulation is effective as one method in the treatment of osteoarthritis.

View Publication Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Antiplatelts Activity of Vitamin E in Relation to Dose and Duration of Therapy
...Show More Authors

           Vitamin E, having the well known antioxidant activity  through scavenging free radicals Ùˆ it occurs in several  isomeric forms , these isomers have relatively different functions . One of these actions is related to its ability to inhibit platelets aggregation and hence thrombosis. The present study included a total number of apparently healthy  62 males . 11of them served as standard group , treated  with 100 mg aspirin /day for more than one month . Another 31 subjects were randomly grouped into 5 groups that received different daily doses of α – tocopherol : 400 IU , 800 IU and 1200 IU for  2-6 months.The remainder ( 20 ) subjects served

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 05 2010
Journal Name
Baghdad Science Journal
Effect of Granulocyte-colony stimulating factor with or without Moxifloxcacin therapy on capsulated Staphylococcus aureus infection in neutropenic mice
...Show More Authors

Twenty bacterial isolates were identified as Staphylococcus aureus collected from wounds and catheters related infections. A capsulated S. aureus isolate was chosen after performing serum soft agar test, for this study Neutropenic mice were challenged with capsulated S. aureus ,and the effect of G-CSF with or without moxifloxacin was studied. The results indicated that the addition of G-CSF to moxifloxacin therapy have a synergistic effect in the killing of the bacteria, while when each G-CSF and moxifloxacin were used seperately have a similar effect on bacterial killing. It was found that the moxifloxacin has the same activity as G_CSF but is less costly than the latter one.

View Publication Preview PDF
Crossref