Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at threshold 10%. The DD/DTA criteria are performed with 3%/3 mm and 2%/2 mm. A significant difference is shown between the measured and calculated point dose for the treatment plans. A comparison made between the gamma passing rate between the 2%/2 mm and 3%/3 mm shows a significant difference for local and global which shows that the 2%/2 mm are more sensitive to dose variation than 3%/3 mm. The total monitor unit (MU) shows a negative linear relationship with both criteria and %GP types. A significant correlation is shown between the total MU and global %GP at 2%/2 mm criterion. The conclusion of the study indicates that 2%/2 mm criterion is more sensitive to the dose distribution changes than the 3%/3 mm. The total number of monitor units should be taken into consideration during the planning of H&N tumors using the IMRT plans.
In the present work the Buildup factor for gamma rays were studied in shields from epoxy reinforced by lead powder and by aluminum powder, for NaI(Tl) scintillation detector size ( ×? ), using two radioactive sources (Co-60 and Cs-137). The shields which are used (epoxy reinforced by lead powder with concentration (10-60)% and epoxy reinforced by aluminum powder with concentration (10-50)% by thick (6mm) and epoxy reinforced by lead powder with concentration (50%) with thick (2,4,6,8,10)mm. The experimental results show that: The linear absorption factor and Buildup factor increase with increase the concentration for the powders which used in reinforcement and high for aluminum powder than the lead powder and decrease with inc
... Show MoreThe article is final after making all the modifications. 2,259 / 5,000 يهدف البحث إلى قياس وتحليل الفجوة بين الواقع الفعلي لبنود التخطيط والدعم وفق المواصفة (IATF16949:2016) في مصنع البطاريات أحد مصانع الشركة العامة لصناعة وتجهيز السيارات، وكذلك التعرف على نقاط القوة والضعف لبنود التخطيط والدعم وفق المواصفة محل البحث. ينطلق البحث من حاجة الشركة العامة لصناعة وتجهيز السيارات إلى إتباع المعايير العالمية في صناعة السيارات والمنتجات المرتبطة بها،
... Show MoreObjective: to assess the awareness and knowledge of our medical students regarding dose levels of imaging procedures and radiation safety issues, and to conclude how the curriculum of clinical radiology in the college medical program impacts such knowledge.
Subjects and methods: this is a cross-sectional study conducted among 150 medical students in Alkindy College of Medicine between January 2021 to July 2021, regardless of their age or gender. The study included six grades according to the year 2020-2021. A questionnaire consisting of 12 multiple-choice questions was conducted via an online survey using Google Forms. The questions were divided into two parts
... Show MoreBACKGROUND: Montelukast (Singulair) is a cysteinyl leukotriene receptor antagonist, used for the maintenance treatment of asthma and to relieve symptoms of seasonal allergic rhinitis and asthma, also used for exercise-induced bronchospasm. AIM: This study was performed to determine the prevalence of Montelukast use as an add-on therapy among Iraqi asthmatic patients on treatment. Comparing the effectiveness of regimens with and without montelukast. METHODS: This descriptive cross-sectional study was carried out on 73 Iraqi asthmatic patients on treatment of both sexes with age range (18-60) years old, attending Al-Kindy Teaching Hospital and Al-Zahraa Centre of Asthma and Allergy, Baghdad, for the period between February
... Show MoreBACKGROUND: Montelukast (Singulair) is a cysteinyl leukotriene receptor antagonist, used for the maintenance treatment of asthma and to relieve symptoms of seasonal allergic rhinitis and asthma, also used for exercise-induced bronchospasm. AIM: This study was performed to determine the prevalence of Montelukast use as an add-on therapy among Iraqi asthmatic patients on treatment. Comparing the effectiveness of regimens with and without montelukast. METHODS: This descriptive cross-sectional study was carried out on 73 Iraqi asthmatic patients on treatment of both sexes with age range (18-60) years old, attending Al-Kindy Teaching Hospital and Al-Zahraa Centre of Asthma and Allergy, Baghdad, for the period between February
... Show MoreAnal fistula is an anorectal condition with over 90% of cases being
cryptoglandular in origin and occurring after anorectal abscesses. The traditional method of
treatment of an anal fistula is by excision or de roofing the tract awaiting complete healing.. Aim:
The aim of this study is to assess the efficacy of diode laser 980 nm in the treatment of low fistula in
ano. Methods: The study was performed between June 2019 to end of September 2019, at the
institute of laser for postgraduate study in Baghdad university. A cohort of ten male patients with a
provisional diagnosis of low type anal fistula were selected for this study and treated by interstitial
photothermal therapy of fistula epithelium by diode laser 980nm
Hypertension is identified as one of the most significant risk factors for cardiovascular diseases (CVDs). There is growing evidence showing that oxidative stress plays a major role in hypertension. Increased production of reactive oxygen species and decrease bioavailability of antioxidant have been demonstrated in experimental and human hypertension. The present study was directed to determine the beneficial effect of the antioxidant vitamin C in patients with essential hypertension treated with the calcium channel blocker (amlodipine) or with the angiotensin converting enzyme inhibitor (enalapril). Ninety six patients (50 females and 46 males) with essential hyp
... Show MoreThis paper deals with, Bayesian estimation of the parameters of Gamma distribution under Generalized Weighted loss function, based on Gamma and Exponential priors for the shape and scale parameters, respectively. Moment, Maximum likelihood estimators and Lindley’s approximation have been used effectively in Bayesian estimation. Based on Monte Carlo simulation method, those estimators are compared in terms of the mean squared errors (MSE’s).