Encryption of data is translating data to another shape or symbol which enables people only with an access to the secret key or a password that can read it. The data which are encrypted are generally referred to as cipher text, while data which are unencrypted are known plain text. Entropy can be used as a measure which gives the number of bits that are needed for coding the data of an image. As the values of pixel within an image are dispensed through further gray-levels, the entropy increases. The aim of this research is to compare between CAST-128 with proposed adaptive key and RSA encryption methods for video frames to determine the more accurate method with highest entropy. The first method is achieved by applying the "CAST-128" and the second is achieved by applying the "RSA ". CAST-128 utilizes a pair of sub-keys for each round as a quantum of five bits that was utilized as a key of rotation for each round and a quantum of 32 (bits) was utilized as a key of masking into a round . The proposed adaptive 128-bits key can be extracted from the main diagonal of each frame before encryption. RSA is a public-key cryptographic technique which can be known as (asymmetric) cryptography. An asymmetry of a key depends on factoring a product of two big prime values. A comparison was applied on several videos and the results showed that CAST-128 method proved the highest degree of entropy even if the frames have lots of distorted data or unclear image pixels. For example, the entropy value of a sample of a girl video is 2581.921 when using CAST-128, while it is 2271.329 when using the RSA; also the entropy value of a sample of a scooter video is 2569.814 when using the CAST-128, while it is 2282.844 when using RSA.
In this study, we introduce new a nanocomposite of functionalize graphene oxide FGO and functionalize multi wall carbon nanotube (F-MWCNT-FGO).The formation of nanocomposite was confirmed by FT-IR ,XRD and SEM. The magnitude of the dielectric permittivity of the (F-MWCNT-FGO) nanocomposite appears to be very high in the low frequency range and show a unique negative permittivity at frequencies range from 400 Hz to 4000Hz. The ac conductivity of nanocomposite reaches 23.8 S.m-1 at 100Hz.
Zinc oxide nanoparticles sample is prepared by the precipitation method. This method involves using zinc nitrate and urea in aqueous solution, then (AgNO3) Solution with different concentrations is added. The obtained precipitated compound is structurally characterized by X-ray diffraction (XRD), Scanning electron microscopy (SEM), Atomic force microscopy (AFM) and Fourier transform infrared spectroscopy (FTIR). The average particle size of nanoparticles is around 28nm in pure, the average particle size reaches 26nm with adding AgNO3 (0.05g in100ml =0.002 M) (0.1g in100ml=0.0058M), AgNO3 (0.2g in 100ml=0.01M) was 25nm. The FTIR result shows the existence of -CO, -CO2, -OH, and -NO2- groups in sample and oxides (ZnO, Ag2O).and used an
... Show MoreRheumatoid arthritis is a worldwide inflammatory chronic autoimmune disease with varying severity. Due to no definitive cure for this disease, current therapies aim to decrease the pain and slow further damage. The interleukin (IL)‐36 cytokine was little known for its role in rheumatoid arthritis; this research aimed to evaluate the serum IL36 levels in RA patients compared to healthy controls. This study included 80 patients with rheumatoid arthritis registered at the Rheumatology Clinic in Baghdad teaching hospital. The patients were divided into three groups based on the treatments received. Group 1 included patients treated with biological therapy (etanercept, adalimumab), Group2 patients with non-biological treatment (methotr
... Show MoreBackground: Knee osteoarthritis (KOA) is a common joint disorder leading to considerable pain and locomotor disability in lower limb function. Locomotor disability, which is difficulty in activities of daily living related to lower limb function, can be the consequence of KOA, so early diagnosis and management may improve quality of life.
Objective: To assess the contribution of radiological osteoarthritis of the knees to disability in the activities of daily living related to lower limb function.
Methods: One hundred twenty Iraqi KOA patients (104 females and 16 males) who were attending to Rheumatology Unit, Full history was taken and complete clinical exami
... Show MoreAbstract
Objective(s): to Evaluation of Parents’ Knowledge about Nutritional Management of kids with Phenylketonuria; to Identify the association between parents’ Knowledge about nutritional management then their demographic variables of fathers, mothers (parents age, residence then socioeconomic position).
Methodology: A non-experimental project; was accompanied on parents of phenylketonuria kid in Baghdad town since the period 3 June to 5 October 2022. A Non-probability sample (convenience) of 35 PKU children and their parents (father and mother) was selected Purposively from the hospitals that are select for the study. A survey is built for the purpose of the educa
... Show MoreThe aim of the present study is to compare the biochemical action of the three vaccines taken in Iraq: Pfizer Biontech, AstraZeneca Oxford and Sinopharm based on biochemical parameters. Seventy COVID-19 Iraqi patients ( males and females ) were participated in the present study and classified into 7 groups : Gc : COVID-19 patients ( without vaccine ) , Gp1: COVID-19 patients took one dose of Pfizer Biontech, Gp2 : COVID-19 patients took two doses of Pfizer Biontech, Ga1 : patients took one dose of AstraZeneca Oxford vaccine , Ga2: patients took two doses of AstraZeneca Oxford vaccine , Gs1 : patients took one dose of Sinopharm vaccine and Gs2:
... Show MoreIn this study, nanocomposites have been prepared by adding
multiwall carbon nanotubes (MWCNTs) with weight ratios (0, 2, 3,
4, 5) wt% to epoxy resin. The samples were prepared by hand lay-up
method. Influence of an applied load before and after immersion in
sodium hydroxide (NaOH) of normality (0.3N) for (15 days) at
laboratory temperature on wear rate of Ep/MWCNTs
nanocomposites was studied. The results showed that wear rate
increases with increasing the applied load for the as prepared and
immersed samples and after immersion. It was also found that epoxy
resin reinforced with MWCNTs has wear rate less than neat epoxy.
The sample (Ep + 5wt% of MWCNTs) has lower wear rate. The
immersion effect in base so