Polycystic ovary syndrome (PCOS) is the main cause of female infertility. The role of insulin resistance in the development of polycystic ovary is actively discussed here. The study included patients with PCOS without insulin resistance (n = 48) and with insulin resistance (n = 39). The comparison groups were patients with no history of PCOS: a control group without insulin resistance (n = 46) and a group of patients with insulin resistance (n = 45). The following parameters were determined in patients: FSH, LH, TSH, T3f, T4f, PRL, E2, 17-OHd, Pr, AMH, Test total, Testf, DHEAS, DHEASs, SHBG, ACTH, cortisol, IRI, IGF-1, C-peptide, and glucose level. The HOMA-IR index and the LH / FSH ratio and the total / SHBG test were calculated. Correlation analysis was also performed between HOMA IR and indicators of the hormonal profile, IGF-1, and C-peptide.Unidirectional changes in the levels of the following hormones were found in insulin resistance, PCOS and / or insulin resistance relative to control values: estradiol, total testosterone, cortisol, prolactin, AMG, and SHBG. As a result of the correlation analysis, negative relationships were established between the HOMA IR Index and the levels of E2, cortisol and AMH in patients (except for the control group).We assume that the formation of the phenotype of polycystic ovary with a combination of insulin resistance can be formed in patients with insulin resistance as a result of a decrease in the level of estradiol, SHBG and an increase in the content of total testosterone and AMH.
In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm−2), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re
In this study, an improved process was proposed for the synthesis of structure-controlled Cu2O nanoparticles, using a simplified wet chemical method at room temperature. A chemical solution route was established to synthesize Cu2O crystals with various sizes and morphologies. The structure, morphology, and optical properties of Cu2O nanoparticles were analyzed by X-ray diffraction, SEM (scanning electron microscope), and UV-Vis spectroscopy. By adjusting the aqueous mixture solutions of NaOH and NH2OH•HCl, the synthesis of Cu2O crystals with different morphology and size could be realized. Strangely, it was found that the change in the ratio of de-ionized water and NaOH aqueous solution led to the synthesis of Cu2O crystals of differen
... Show MoreGenerally fossil based fuels are used in internal combustion engines as an energy source.
Excessive use of fossil based fuels diminishes present reserves and increases the air pollution in
urban areas. This enhances the importance of the effective use of present reserves and/or to develop
new alternative fuels, which are environment friendly. Use of alternative fuel is a way of emission
control. The term “Alternative Gaseous Fuels” relates to a wide range of fuels that are in the
gaseous state at ambient conditions, whether when used on their own or as components of mixtures
with other fuels.
In this study, a single cylinder diesel engine was modified to use LPG in dual fuel mode to study
the performance, emis
The adsorption of Cr (VI) from aqueous solution by spent tea leaves (STL) was studied at different initial Cr (VI) concentrations, adsorbent dose, pH and contact time under batch isotherm experiments The adsorption experiments were carried out at 30°C and the effects of the four parameters on chromium uptake to establish a mathematical model description percentage removal of Cr (VI). The
analysis results showed that the experimental data were adequately fitted to second order polynomial model with correlation coefficients for this model was (R2 = 0.9891). The optimum operating parameters of initial Cr (VI) concentrations, adsorbent dose, pH and contact time were 50 mg/l, 0.7625 g, 3 and 100 min, respectively. At these conditions, th