Trichomonas vaginalis is a causative agent of trichomoniasis , one of the most common non-viral sexually transmitted disease (STD) over all the world, especially in immunocompromised women such as pregnant. Wet smear and Giemsa stain are the current methods used in hospital to diagnosis trichomoniasis. DNA based diagnosis is still to be validated to diagnose the local isolates, the objective of the present study was to compare the conventional methods of disease diagnosis with the DNA-based method to diagnose Trichomonas incidence in local isolates. In the present study, 105 samples were collected from outpatient women (18-45 years) of Maternity hospital in Mosul who showed a classical presentation of Trichomonas infection including foul-smelling vaginal discharge with a pH exceeding 4.5. Samples underwent microscopic examination and nucleic acid detection of AP65-1 gene, the wet smear test showed that 16.18% of the collected specimen were positive while the parasite appeared only in 8.9% of the samples stained with Giemsa dye, the molecular screening for AP65-1gene that encodes for the surface attachment protein showed high sensitivity level of 100 at 50 specificity level in compare with other routine methods, the algorithm was evaluated according to specificity, sensitivity, and predictive values. Random Amplification Polymorphic DNA (RAPD) was achieved to estimate genetic indices among isolated strains. Phylogenetic analysis was performed using PAST (Paleontological statistics software) and dendrogram with neighboring clusters was constructed. According to the outcomes of research, we recommended to utilize a probiotic vaccines and molecular silencing vaccine (like miRNA sense and antisense oligonucleotides) as a treatment in.
Real Time Extended (RTX) technology works to take advantage of real-time data comes from the global network of tracking stations together with inventor locating and compression algorithms to calculate and relaying the orbit of satellite, satellite atomic clock, and any other systems corrections to the receivers, which lead to real-time correction with high accuracy. These corrections will be transferred to the receiver antenna by satellite (where coverage is available) and by IP (Internet Protocol) for the rest of world to provide the accurate location on the screen of smartphone or tablet by using specific software. The purpose of this study was to assess the accuracy of Global Navig
Gas adsorption phenomenon on solid surface has been used as a mean in separation and purification of gas mixture depending on the difference in tendencies of each component in the gas mixture to be adsorbed on the solid surface according to its behaviour. This work concerns to study the possibilities to separate the gas mixture using adsorption-desorption phenomenon on activated carbon. The experimental results exhibit good separation factor at temperature of -40 .
Background: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MorePots experiment was conducted at the greenhouse of botanical garden belong to Department of Biology, College of Education for Pure Science, Ibn-AL-Haithum, University of Baghdad, for growth season 2018-2019. The aim of the experiment was to study the effects of foliar application of a-tocopherol concentrations (0, 50, 100, 150, 200 mg.L-1) on growth parameters and the activity of some antioxidant enzymes of wheat plant irrigated with sodium chloride concentrations (0, 75, 150, 225) mM.L-1. Salinity reduced plant growth parameter, plant height, flag leaf area, flag leaf chlorophyll content and increased the activity of antioxidant enzymes, superoxide dismutase and peroxidase. Plant growth parameters were enhanced by foliar application of a-t
... Show MoreIn this work, spinel ferrites (NiCoFe2O4) were prepared as thin films by dc reactive dual-magnetron co-sputtering technique. Effects of some operation parameters, such as inter-electrode distance, and preparation conditions such as mixing ratio of argon and oxygen in the gas mixture, on the structural and spectroscopic characteristics of the prepared samples were studied. For samples prepared at inter-electrode distance of 5 cm, only one functional group of OH- was observed in the FTIR spectra as all bands belonging to the metal-oxygen vibration were observed. Similarly, the XRD results showed that decreasing the pressure of oxygen in the gas mixture lead to grow more crystal planes in the samples prepare
... Show MoreIn this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth