Preferred Language
Articles
/
bsj-569
Using He-Ne laser irradiation for enhancing cartilage Autografts
...Show More Authors

thirty adult NewZealand rabbits used in this study, they were divided in to two groups (control and treaded with Helium — Neon laser). A square skin flap done on the medial aspect of the auricle of both sides, a square piece of cartilage incised, pealed out from each auricle and fixed in the site of the other, then the flaps sutured .The site of the operation in the rabbits of the treated group were irradiated using a Helium —Neon laser with (5mw) power for (10 days) began after the operation directly, (3 rabbits) from each group used for collection of specimens for histopathological examination at the weeks (1,2,3,4, & 6) weeks post the operation .The results revealed Early invasion of the matrix with elastic fibers which continue to the surrounding perichondrium, mature lacunae and complete healing occurred later at the 6th week in the treated group. Conclusion: Helium- Neon laser raised the mitotic activity of the cartilage cells, activated the reproduction processes in addition to the intra and extra regenerative reparation.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Enhancement of Episiotomy Healing Using (790-805) nm Diode Laser as a Supplementary Treatment
...Show More Authors

To show the impact of 790-805 nm diode laser irradiations on wound healing as a supplementary treatment in women underwent episiotomies, and to assess the laser parameters that were used .Material and methods: Eighteen female patients were included in this study; all of them underwent mediolateral episiotomy. Ten patients received laser therapy- diode laser (K Laser) (790-805) nm in CW mode of operation (and eight patients were the control group. Spot size of 8mm, time for exposure for each spot was 30 seconds. The power used was 0.6 W .The power density for each spot of treatment was 1.19 W/cm2 per session (non contact mode of application of laser therapy).The group studied received 2 sessions of laser radiation, day 4, and day 8 after

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
E3s Web Of Conferences
Enhancing the Ability of The Square Footing to Resist Positive and Negative Eccentric Inclined Loading Using an Inclined Skirt
...Show More Authors

Laboratory model tests were performed to investigate the behavior of shallow and inclined skirted foundations placed on sandy soil with R.D%=30 and the extent of the impact of the positive and negative eccentric-inclined loading effect on them. To achieve the experimental tests, it was used a box of (600×600) mm cross-sectional and 600mm in height and a square footing of (50*50) mm and 10 mm in thickness attached to the skirt with Ds=0.5B and various an angle of (10°, 20°, 30°). The results showed that using skirts leads to a significant improvement in load-carrying capacity and decreased settlement. In addition, when the skirt angle increased, the ultimate load improved. Load-carrying capacity decreased with increasing eccentri

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
CFIA-Turbidimetric and Photometric Determination of Vitamin B9 (Folic acid) Using LEDs as a Source of Irradiation and Two Solar Cells as an Energy Transducer
...Show More Authors

A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv

... Show More
View Publication Preview PDF
Scopus (6)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Positron Annihilation Lifetime Study on free Volume Changes in TLD by Gamma - irradiation
...Show More Authors

Positron annihilation lifetime has been utilized for the first time to investigate the free - volume hole properties in thermolumenscent dosimeter ( TLD ) as a function of gamma-dosc . The hole volume, free volume fraction determined form orthopsitronium lifetime are found to be ?lamatically increase to large values , and then to minimum values as a function ofgamma-dose . The free - volume holes size is found to be 0.163nm’ and to have maximum of 0.166nm^ at the gamma-dose of 0.1 and 0.8 Gy, respectively-

View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Physics: Conference Series
Study the effect of gamma Irradiation on the Superconducting Properties of HgBaSrCa2Cu3O8+δ
...Show More Authors

Publication Date
Thu Oct 14 2021
Journal Name
Iraqi Journal Of Physics
Investigation of nonlinear optical properties for laser dyes-doped polymer thin film
...Show More Authors

Solutions of dyes Rhodamine 6G (Rh6G) and Coumarin480(C480) were prepared at five concentrations (1x10-3, 5x10-4, 1x10-4, 5x10-5 and1x10-5) mol/l, the mixing was stirred to obtain on a homogenous solution, the(poly methyl-methacrylate) (PMMA) was solved by chloroform solvent with certain ratio, afterward (PMMA+Rh6G) and (PMMA+C480) thin films were prepared by casting method on glass block which has substrate with dimensions (7.5 x2.5)cm2, the prepared samples were left in dark place at room temperature for 24 hours to obtain uniform and homogenous thin films. UV-VIS absorption spectra, transmission spectra and fluorescence spectra were done to measure linear refractive index and linear absorption coefficient. The nonlinear optical proper

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
International Journal Of Science And Technology (ijst)
Study of Optical and Structures for TiO2 prepared by Pulse Laser Deposition
...Show More Authors

Publication Date
Fri Jan 01 2021
Journal Name
Materials Today:proceeding
Modification of CR39 surfaces by 193 nm ArF laser for biomaterial sensing
...Show More Authors

Scopus (3)
Scopus
Publication Date
Fri Feb 01 2013
Journal Name
Journal Of Physical Science And Application
Photobleaching Influence in Different Phases for Coumarin 307 and Acriflavine Laser Dyes
...Show More Authors

Abstract: Under high-excitation irradiance conditions to induce fluorescence, the dependence of photobleaching of Coumarin 307 (C307) and acriflavine (ACF) laser dyes in liquid and solid phases have been studied. A cw LD laser source of 1 mW and 407 nm wavelength was used as an exciting source. For one hour exposure time, it was found that the solid dye samples suffer photobleaching more than the liquid dye samples. This is because in liquid solutions the dye molecules can circulate during the irradiation, while the photobleaching is a serious problem when the dye is incorporated into solid matrix and cannot circulate.

Preview PDF