This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) buffer to yield a reddish/orange colour change proportional to the iron(II) concentration measured at λmax = 510 nm. Under optimum conditions, the calibration curve was linear in the range between (0.5-150) mg L-1 with a limit of detection of 0.09 mg L-1. Compared to a spectrophotometric detection method, µPAD measured colour intensity using captured images using Samsung mobile phone and image J program to give proof of concept that µPAD platform fulfils the purpose of accuracy and at the same time remaining cost-effective and simplistic to be used in both developing and developed countries gave same linear calibration curve with a limit of detection 0.12 mg L-1. ANOVA test was used to compare the proposed method results with conventional method results showing the method was accepted. The antimicrobial activity showed no significant effect from lipstick samples on tested microbes.
Objectives. This study was carried out to quantitatively evaluate and compare the sealing ability of Endoflas by using differentobturation techniques. Materials and Methods. After 42 extracted primary maxillary incisors and canines were decoronated, theircanals were instrumented with K files of size ranging from #15 to #50. In accordance with the obturation technique, the sampleswere divided into three experimental groups, namely, group I: endodontic pressure syringe, group II: modified disposable syringe,and group III: reamer technique, and two control groups. Dye extraction method was used for leakage evaluation. Data wereanalyzed using one-way ANOVA and Dunnett’s T3 post hoc tests. The level of significance was set at p<0:05. Results.
... Show MoreAn optical spectroscopic study is reported in this article to study the correlation between the supermassive black hole (SMBH) and the star formation rate (SFR) for a sample of Seyfert galaxies type (I and II). The study focused on 45 galaxy of Seyfert 1, in addition to 45 galaxy of Seyfert 2, where these samples have been selected form different survey of Salon Digital Sky Survey (SDSS). The redshift (z) of these objects were between (0.02 – 0.26). The results of Seyfert 1 galaxies shows that there good correlation between the SMBH and the SFR depending on statistical analysis parameter named Spearman’s Rank Correlation in a factor of (ρ=0.609), as well as the Seyfert 2 galaxies results show a good correlation between the SMBH and
... Show MoreAn optical spectroscopic study is reported in this article to study the correlation between the supermassive black hole (SMBH) and the star formation rate (SFR) for a sample of Seyfert galaxies type (I and II). The study focused on 45 galaxy of Seyfert 1, in addition to 45 galaxy of Seyfert 2, where these samples have been selected form different survey of Salon Digital Sky Survey (SDSS). The redshift (z) of these objects were between (0.02 – 0.26). The results of Seyfert 1 galaxies shows that there good correlation between the SMBH and the SFR depending on statistical analysis parameter named Spearman’s Rank Correlation in a factor of (ρ=0.609), as well as the Seyfert 2 galaxies results show a good correlation between the SMBH
... Show MoreA new carbonyl complexes of triazole and oxadiazole were synthesized. These complexes were identified and their structural geometric were suggested by using FT-IR and UV-Vis spectra, conductivity measurements and other chemical and physical properties. The spectra data (FT-IR, UV, Vis.) with the substantial aid of group theoretical calculations gave so many evidences for the proposed geometries and the type of bonding of these compounds
mixtures of cyclohexane + n-decane and cyclohexane + 1-pentanol have been measured at 298.15, 308.15, 318.15, and 328.15 K over the whole mole fraction range. From these results, excess molar volumes, VE , have been calculated and fitted to the Flory equations. The VE values are negative and positive over the whole mole fraction range and at all temperatures. The excess refractive indices nE and excess viscosities ?E have been calculated from experimental refractive indices and viscosity measurements at different temperature and fitted to the mixing rules equations and Heric – Coursey equation respectively to predict theoretical refractive indices, we found good agreement between them for binary mixtures in this study. The variation of th
... Show MoreThe experiment was aimed to evaluate a locally manufactured a dual-action device used for measuring feed pellets durability. The device performs dropping process in conventional devices, then sifting process to separate the pellets from the crumbles simultaneously, with a control the motor speed by using the pulse width modulation (PWM) Technique. The device performance was compared with the durability measuring device of a moving drop box. Rotational speed, diameter of the die holes of the machine was used in this study. The results showed that increasing the rotational speed of the die from 280 to 300 and to 320 rpm, increasing the die holes diameter from 3 to 4 and to 5 mm, led to
A new method for determination of allopurinol in microgram level depending on its ability to reduce the yellow absorption spectrum of (I-3) at maximum wavelength ( ?max 350nm) . The optimum conditions such as "concentration of reactant materials , time of sitting and order of addition were studied to get a high sensitivity ( ? = 27229 l.mole-1.cm-1) sandal sensitivity : 0.0053 µg cm-2 ,with wide range of calibration curve ( 1 – 9 µg.ml-1 ) good stability (more then24 hr.) and repeatability ( RSD % : 2.1 -2.6 % ) , the Recovery % : ( 98.17 – 100.5 % ) , the Erel % ( 0.50 -1.83 % ) and the interference's of Xanthine , Cystein , Creatinine , Urea and the Glucose in 20 , 40 , 60 fold of analyate were also studied .
Neuroendocrine differentiation has been mentioned in many cancers of non-neuroendocrinal organs, involving the gastrointestinal tract. In contrast, the correlation of focally diffused neuroendocrine differentiation in colorectal adenocarcinoma with neuroendocrine cell hyperplasia has not been somewhat reported. The objective of this research is to study the relationship between neuroendocrine cell hyperplasia and neuroendocrine differentiation in colorectal adenocarcinoma and to find the correlation of neuroendocrine differentiation and VEGF expression with clinicopathological parameters of colorectal adenocarcinoma. Methods employed in the current study were including eighty-one patients with colorectal cancer. Formalin fixed paraffin e
... Show More