Chronic myeloid leukemia (CML) is a myeloproliferative disorder characterized by the presence Philadelphia chromosome (Ph) which was created by a reciprocal translocation between chromosomes 9 and 22 (t [9;22] [q34;q11]. The approval of the 2nd generation TKI ( Nilotinib) takes the treatment of CML patients into new erea with more efficiency and mild to moderate adverse effects. This study was aimed at evaluation of molecular cytogenetic response by (FISH) for Nilotinib in Iraqi patients with assessment for electrolytes disturbances of Nilotinb by measuring a panel of electrolyte (Na+, K+, Ca++, PO4--- and Mg++) , where thirty Iraqi patients with CML who have resistance or no response to Imatinib treatment, attending to Baghdad Teaching Hospital/Hematology Department, have been submitted to this study. Blood samples have been taken pre and post starting treatment with Nilotinib, FISH study was done only for CML patients, while 30 normal healthy control volunteers submitted to the same panel of electrolytes measurements (Na+, K+, Ca++, PO4--- and Mg++) in addition to pre and post treatment Nilotinib patients. The results show out of 30 patients (17) males and (13) females with male to female ratio 1.3:1, FISH results for patients (pre and post) treatment mean±SD were(58.7%±26.2 % and 45.7%±29.9%) obviously significant with good cytogenetic response in resistance CML for Imatinib. Sodium levels in mmol/L pre, post treatment and control mean±SD were (139.2±6.9 , 142.4±9.2 and 140.4±2.52) respectively, with no significant difference between each other with P value > 0.05 in all comparisons. Potassium levels mean±SD in mmol/L results for patients (pre, post) and control were (4.6±0.69, 4.3±0.68 and 4.46±0.76) respectively, with no significant difference between each other with P value > 0.05 in all comparisons. Calcium levels in mg/dL results for patients (pre, post) and control as mean±SD were (8.68 ±1.68, 8.1±1.72 and 9.12±0.38) respectively with no significant differences except between post treatment and control group with P value > 0.05 in all comparisons. Phosphate levels in mg/dL results for patients (pre, post) and control as mean±SD were (2.5±0.84, 2.95±1.04 and 3.4±0.49) respectively with significant difference with P value < 0.05 in all comparisons. Magnesium levels in mg/dL results for patients pre, post and control as mean±SD were (1.93±0.34, 2.06±0.44 and 2.1±0.34) respectively with no significant difference between each other with P value > 0.05 in all comparisons. This study sheds a light on the molecular cytogenetic response for CML patients who have already resistance to Imatinib and Nilotinib that has much more potent effect as approved by studies and this study has used FISH technique. This study emphasizes on the importance of evaluation of electrolyte panel for CML patients before starting Nilotinib study taking in to consideration if these patients are already receiving Imatinib which can also affect bone metabolism and calcium and phosphate levels.
We aimed to obtain magnesium/iron (Mg/Fe)-layered double hydroxides (LDHs) nanoparticles-immobilized on waste foundry sand-a byproduct of the metal casting industry. XRD and FT-IR tests were applied to characterize the prepared sorbent. The results revealed that a new peak reflected LDHs nanoparticles. In addition, SEM-EDS mapping confirmed that the coating process was appropriate. Sorption tests for the interaction of this sorbent with an aqueous solution contaminated with Congo red dye revealed the efficacy of this material where the maximum adsorption capacity reached approximately 9127.08 mg/g. The pseudo-first-order and pseudo-second-order kinetic models helped to describe the sorption measure
CR-39 is a solid state nuclear track detector (SSNTD) that has been used in many research areas. In spite of the assumption that the CR-39 detectors are insensitive to beta and gamma rays, irradiation with these rays can have significant effects on the detector properties. In this study, beta and gamma rays mass attenuation coefficients μ/ρ (cm2 g-1) for the CR-39 detector have been measured using NaI(Tl) scintillation spectrometer along with a standard geometrical arrangement in the energy region of (0.546-2.274) MeV beta rays and standard gamma sources having energy 0.356, 0.5697, 0.6617 and 1.063 MeV. The total atomic cross-section (σtot), total electronic cross-section (σT E) and the effective atomic number (Zeff) of gamma rays a
... Show MoreThis study aimed at examining the role played by the media outlets during the coverage
of the presidential election campaigns 2020 of the United States of America.
The analytical study used through a partial inventory of the research community
for almost three months from the announcement of the candidates’ names by
the major parties on August 13 to November 6، which is the official election day in
the U.S. National Public Radio Station (NPR) to achieve the objectives of the study.
The study reached a number of conclusions related to the contents، methods and
sources of media coverage of the election campaigns of the 2020 U.S. at the mentioned
station، where the researcher proposed a number of recommendations
In this article, we developed a new loss function, as the simplification of linear exponential loss function (LINEX) by weighting LINEX function. We derive a scale parameter, reliability and the hazard functions in accordance with upper record values of the Lomax distribution (LD). To study a small sample behavior performance of the proposed loss function using a Monte Carlo simulation, we make a comparison among maximum likelihood estimator, Bayesian estimator by means of LINEX loss function and Bayesian estimator using square error loss (SE) function. The consequences have shown that a modified method is the finest for valuing a scale parameter, reliability and hazard functions.
Thirteen morphometric characters of catfish