Preferred Language
Articles
/
bsj-526
Performance evolution of a hybrid thermal solar air conditioning system and compare it with a traditional system according to Iraq weather
...Show More Authors

In a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amount of energy and current consumption of the two systems at the same operating conditions. The energy consumed and the current of the hybrid system were less than the traditional air-conditioning system by 12% and 28.6% respectively, which means that there is a saving in the energy and current consumption as a result of the use of the solar thermal collector.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Performance of Different Concatenated Coding Schemes for CDMA System
...Show More Authors

In this paper different channel coding and interleaving schemes in DS/CDMA system over multipath fading channel were used. Two types of serially concatenated coding were presented. The first one composed of Reed-Solomon as outer code, convolutional code as inner code and the interleaver between the outer and inner codes and the second consist of convolutional code as outer code, interleaved in the middle and differential code as an inner code. Bit error rate performance of different schemes in multipath fading channel was analyzed and compared. Rack receiver was used in DS/CDMA receiver to combine multipath components in order to enhance the signal to noise ratio at the receiver.

 

View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Engineering And Applied Sciences
Effect of silver doping for performance of CdS solar cell prepared by thermal vacuum evaporation
...Show More Authors

Publication Date
Tue Jan 01 2019
Journal Name
Journal Of The College Of Languages (jcl)
To Shape a Silence While Breaking it: Toni Morrison’s the Bluest Eye
...Show More Authors

Toni Morrison (1931-), the first African-American winner of Noble Prize in literature (1993) and the winner of the 1988 Pulitzer Prize for fiction, regards herself as the historian of African-American people. She does not think of her writings as literature but as a sacred book dedicated to explore the interior lives of blacks. She creates history by disregarding European standards and the white man's view of African- Americans. She adopts her people's point of view, invests their heritage, voices their pains and uses their vernacular. She even writes to a black audience. She establishes the black novel  by depicting the blackness of American literature. In choos

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
Promoting Solar Cell Efficiencies via Employing Sliver- Carbon- Pomegranate Peel Nano System
...Show More Authors

In this work, a functional nanocomposite consisting of multi walled carbon nanotubes combined with nanoparticles of silver and Pomegranate peel extract (MWCNTs- SNPs -NPGPE) was successfully synthesized using ultra sonic technique. The nanocomposite has been characterized using Transmission electron microscope (TEM), XRD, Energy dispersive X-ray spectroscopy (EDS) UV-Vis and FTIR. The obtained results reveal that the MWCNTs-SNPs-NPGPE nanocomposite exhibits form of nanotubes with rough surfaces and containing black spots, which are the silver nanoparticles. The dimensions of this tube are 161 nm in length and 60 nm in width with nanoparticles of silver not exceeding 20 nm. The XRD pattern of the prepared MWCNTs-SNPs-NPGPE nanocomposite s

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Compare to the conditional logistic regression models with fixed and mixed effects for longitudinal data
...Show More Authors

Mixed-effects conditional logistic regression is evidently more effective in the study of qualitative differences in longitudinal pollution data as well as their implications on heterogeneous subgroups. This study seeks that conditional logistic regression is a robust evaluation method for environmental studies, thru the analysis of environment pollution as a function of oil production and environmental factors. Consequently, it has been established theoretically that the primary objective of model selection in this research is to identify the candidate model that is optimal for the conditional design. The candidate model should achieve generalizability, goodness-of-fit, parsimony and establish equilibrium between bias and variab

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH3 – H2O SYSTEM
...Show More Authors

This work was conducted to study the coefficient of performance for solar absorption refrigeration by using direct solar energy using aqueous ammonia 0.45 mass fraction (ammonia – water).The experiments were carried out in solar absorption system .The system consisted of solar collector generator (0.25 m × 0.25 m × 0.04m) and condenser cooled by a water bath followed by liquid receiver and evaporator. The results showed that the maximum generator temperature was (92° - 97°) during June 2009, and the minimum evaporator temperature was (5°C - 10°C) for aqua ammonia system.. It was, also, found that the coefficient of performance, cooling ratio and amount of cooling obtainable increased with increasing maximum generator temperature

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit Using RSM Technique
...Show More Authors

The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Journal Of Economics And Administrative Sciences
An Evaluation of Environmental Performance According to The International Standard (ISO14001: 2015) in a Field East of Baghdad / A Case Study in the Midline Oil Company
...Show More Authors

EMS in accordance with ISO 14001: 2015 is considered an entry point to reduce environmental impacts, especially the effects resulting from the oil industry, which is the main source of environmental pollution and waste of natural resources, since the second revision of the standard took place in September 2015. The problem of the research was manifested in the weakness in understanding the correct guidelines that must be followed in order to obtain and maintain the standard. The purpose of this research was to give a general picture of what is behind ISO14001:2015 and how it is possible to create a comprehensive base for understanding its application by seeking the gap between the actually achieved reality, standards requirements

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 03 2020
Journal Name
Modern Sport
Exercises based on the phosphogenic energy system to develop the ability to perform with precision and accuracy
...Show More Authors

Each sport has its own energy requirements that differ from the energy requirements of other sports, and a different method is used in each of them, so the trainer must first rely on the principle of privacy in training first, that is, privacy according to the working energy system, that is, he defines the controlling energy system In that event, and how the muscles use the available energy to perform according to the energy production systems. As we find the serving skill is the first volleyball skill with which the team starts the match in order to be able to gain points directly, through knowledge it turns out that there is a weakness in the skill performance, especially the skill of serving and being The key to victory for volle

... Show More
Crossref (1)
Crossref
Publication Date
Sat Jan 06 2024
Journal Name
International Journal Of Applied Engineering & Technology
A PROPOSED LIGHTWEIGHT BLOCK CIPHER SYSTEM EMPLOYING DNA CODES
...Show More Authors