Preferred Language
Articles
/
bsj-5230
Enhancement of Electron Temperature under Dense Homogenous Plasma by Pulsed Laser Beam
...Show More Authors

The applications of hot plasma are many and numerous applications require high values of the temperature of the electrons within the plasma region. Improving electron temperature values is one of the important processes for using this specification in plasma for being adopted in several modern applications such as nuclear fusion, plating operations and in industrial applications. In this work, theoretical computations were performed to enhance electron temperature under dense homogeneous plasma. The effect of   power and duration time of pulsed Nd:YAG laser   was studied on the heating of   plasmas  by inverse bremsstrahlung  for  several values for the electron density ratio. There results for these calculations showed that the effect of increasing the values of the laser pulse power (25-250kW) led to decrease the absorption coefficient values by 58.3% and increase the electron temperature by 50.0% at duration pulse time 0.5ns and electron density ratio 0.1. Furthermore, the ratio of electron density increasing and pulse duration time led to increase the higher values of the electron temperature. The results of the calculations showed the effect of the laser power, the percentage of electron density, and the pulse duration for improving the electron temperature. It is possible to control the temperature of the electrons with one of the plasma parameters or the laser beam used, and that it gives a clear indication of researchers in this field to choose the optimal wavelength of the laser beam and    electron density ratios for the plasma.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of a Power System Transient Stability Using Static Synchronous Series Compensator SSSC
...Show More Authors

Static Synchronous Series Compensator (SSSC) is a well known device for effectively regulating the active power flow in a power system. In this paper, the SSSC linearized power flow equations are incorporated into Newton-Raphson algorithm in a MATLAB written program to investigate the control of active poweer flow and the transient stability of a five bus and a thirty bus IEEE test systems, during abnormal conduction (three phase fault near buses). A comparison of the results obtained for the base case without SSSC and with it to investigate the effectiveness of the device on both of the active power flow and the transient stability.

View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Enhancement of thermal stability and wettability for epoxy/Cu coated carbon fiber composites
...Show More Authors

    This research study the effect of surface modification and copper (Cu) plating carbon fiber (CF) surface on the thermal stability and wettability of carbon fiber (CF)/epoxy (EP) composites. The TGA result indicates that the thermal-stability of carbon fiber may be enhanced after Cu coating CF. TGA curve showed that the treatment temperature was enhanced thermal stability of Ep/CF, this is due to the oxidation during heating. The Cu plating increased the thermal conductivity, this increase might be due to reduce in contact resistance at the interface due to chemical modification and copper plating and tunneling resistance.

   The increase of surface polarity after coating cause decreas

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Iraqi Journal Of Physics
Enhancement CT Scan Image and Study Electronic, Structural and Vibrational Properties of Iobenguane
...Show More Authors

This work is divided into two parts first part study electronic structure and vibration properties of the Iobenguane material that is used in CT scan imaging. Iobenguane, or MIBG, is an aralkylguanidine analog of the adrenergic neurotransmitter norepinephrine and a radiopharmaceutical. It acts as a blocking agent for adrenergic neurons. When radiolabeled, it can be used in nuclear medicinal diagnostic techniques as well as in neuroendocrine antineoplastic treatments. The aim of this work is to provide general information about Iobenguane that can be used to obtain results to diagnose the diseases. The second part study image processing techniques, the CT scan image is transformed to frequency domain using the LWT. Two methods of contrast

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Data Acquisition System for Wind Speed, Direction and Temperature Measurements
...Show More Authors

This paper describes the use of microcomputer as a laboratory instrument system. The system is focused on three weather variables measurement, are temperature, wind speed, and wind direction. This instrument is a type of data acquisition system; in this paper we deal with the design and implementation of data acquisition system based on personal computer (Pentium) using Industry Standard Architecture (ISA)bus. The design of this system involves mainly a hardware implementation, and the software programs that are used for testing, measuring and control. The system can be used to display the required information that can be transferred and processed from the external field to the system. A visual basic language with Microsoft foundation cl

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Temperature dependence energy distribution function for proton-tritium fusion reaction
...Show More Authors

The physical behavior for the energy distribution function (EDF) of the reactant particles depending upon the gases (fuel) temperature are completely described by a physical model covering the global formulas controlling the EDF profile. Results about the energy distribution for the reactant system indicate a standard EDF, in which it’s arrive a steady state form shape and intern lead to fix the optimum selected temperature.

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of certain radiomorphometric facial indices in different facial types of Iraqi adults using Cone Beam Computed Tomography
...Show More Authors

Background: The human face has its special characteristics. It may be categorized into essentially three kinds in horizontal and vertical directions: short or brachyfacial, medium or mesofacial and long or dolichofacial. The aim of this study was to describe several orofacial indices and proportions of adults, according to gender in Iraqi subjects by using cone beam computed tomography . materials and methods: This prospective study included 100 Iraqi patients (males and females) ranging from 20 to 40 years. All subjects attended the Oral and Maxillofacial Radiology Department of Health Specialist Center for Dentistry in AL Sadr city in Baghdad taking cone beam computed tomography scan for different diagnostic purposes from October 2016 to

... Show More
View Publication
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
EFFCT OF HOOPS AND COLUMN AXIAL LOAD ON SHEAR STRENGTH OF HIGH-STRENGTH FIBER REINFORCED BEAM-COLUMN JOINTS
...Show More Authors

A reinforced concrete frame is referred as "RIGID FRAMES". However, researches indicate that the Beam-Column joint (BCJ) is definitely not rigid. In addition, extensive research shows that failure may occur at the joint instead of in the beam or the column. Joint failure is known to be a catastrophic type which is difficult to repair.
This study was carried out to investigate the effect of hoops and column axial load on the shear strength of high-strength fiber reinforced Beam-Column Joints by using a numerical model based on finite element method using computer program ANSYS (Version 11.0). The variables are: diameter of hoops and magnitude of column axial load.
The theoretical results obtained from ANSYS program are in a good a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Role of Cone Beam Computed Tomography in Determination of the Greater Palatine Foramen Position Among Iraqi Population
...Show More Authors

Background: The use of the cone beam computed tomography for analysing the position of the greater palatine foramen in relation to various anatomical landmarks is crucial in dentistry. The aims of the current study, firstly is to determine the greater palatine foramen position in relation to various anatomical landmarks by using cone beam computed tomography and secondly is to make a comparison of the measurements according to side, gender, and age. Materials and methods: This prospective study included 60 Iraqi patients (28males and 32 females) who selected according to availability of Inclusion criteria, which include age range (21 - 60 years), with no dentofacial deformities or pathological lesion at the maxilla. All patients had inform

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Mon Sep 20 2021
Journal Name
Journal Of Craniofacial Surgery
Presurgical Assessment of Anatomical Landmark Position Using Two Views of Cone Beam Computed Tomography: A Comparative Radiological Study
...Show More Authors

View Publication
Scopus (2)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue May 03 2022
Journal Name
Teikyo Medical Journal
Tooth agenesis and palatal dimensions associated with craniofacial deformity- Cone Beam Computed Tomography based study
...Show More Authors

Cleft / palate is one of the common congenital deformities in craniofacial region, associated with different types of dental anomalies like (Tooth agenesis, impaction, and supernumerary teeth) with marked changes in palatal dimensions. This study aimed to determine the prevalence of teeth agenesis and dental anomalies in cleft lip/palate patients using CBCT, and to compare the palatal dimension of cleft group with control subjects. Twenty-eight cleft cases collected during the period from 2015 to 2022, CBCT images evaluated, the study sample classified into two groups (14 bilateral and 14 unilateral cleft lip/palate) and the non-cleft control group (14 CBCT images). The presence of dental anomalies was assessed in relation to clef

... Show More