Potentiostatic polarization and weight loss methods have been used to investigate the corrosion behavior of carbon steel in sodium chloride solution at different concentrations (0.1, 0.4 and 0.6) M under the influence of temperatures ( 293, 298, 303, 308 and 313) K. The inhibition efficiency of the amoxicillin drug on carbon steel in 0.6 M NaCl has also been studied based on concentration and temperature. The corrosion rate showed that all salt concentrations ( NaCl solution) resulted in corrosion of carbon steel in varying ratio and 0.6 M of salt solution was the highest rate (50.46 g/m².d). The results also indicate that the rate of corrosion increases at a temperature of 313 K.. Potentiodynamic polarization studies showed that the examined inhibitor suppress both anodic and cathodic process and behave as mixed type inhibitor. The adsorption of amoxicillin was found to obey Langmuir isotherm model. Arrhenius equation and transition state theory were used to calculate kinetic and thermodynamic parameter. Results obtained showed that corrosion reaction of carbon steel in NaCl is spontaneous and there is a good agreement between the data got from the both techniques employed. SEM analysis was performed to study the film persistency of the inhibitor.
A simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
Background: This study is to evaluate the necessity of prescribing prophylactic antibiotics for nasal packing in spontaneous epistaxis. There are few published papers of infective complications in such patients.
Methods: This prospective study analysed 149 consecutive patients admitted to AL-Kindy teaching hospital with spontaneous, epistaxis, who underwent nasal packing over 2 years period . in the first year, 78 patients received prophylactic antibiotics , In the second year 71 patients were not given prophylatic antibiotics. Exclusion criteria included antibiotics prescribed for unrelated pathology and post-operative epistaxis. Signs and symptoms of acute otitis m
... Show MoreA UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show MoreRotaviruses, a major cause of gastroenteritis in children worldwide accounts for around half a million deaths annually. Vaccine against the virus has been recommended by the WHO to be involved in the national immunization program.To evaluate the genetic characterization of rotavirus among children with acute gastroenteritis in Babylon province is warranted. Children complained of diarrhea with rotavirus infection detected in their stool were involved in the study. The age range was 10 months to 60 months and with retrogradechecking of rotavirus vaccine history. Rotavirus genotypes were detected by reverse transcription-polymerase chain reaction (RT-PCR).A total number of 40 children with rotavirus gastroenteritis were used to examine the
... Show More