In this work, the switching nonlinear dynamics of a Fabry-Perot etalon are studied. The method used to complete the solution of the differential equations for the nonlinear medium. The Debye relaxation equations solved numerically to predict the behavior of the cavity for modulated input power. The response of the cavity filled with materials of different response time is depicted. For a material with a response time equal to = 50 ns, the cavity switches after about (100 ns). Notice that there is always a finite time delay before the cavity switches. The switch up time is much longer than the cavity build-up time of the corresponding linear cavity which was found to be of the order of a few round-trip times. The slowing down of the cavity response occurs when the incident intensity is approximately equal to the critical switching intensity. This effect is called critical slowing down. As a result, the response of the cavity is much slower than what could be expected from the steady state analysis. The reflected intensity and the change in round-trip phase have similar dynamic response. In this research, the matlap programs are used to study the switching dynamics of a Fabry-Perot etalon.
The fluorescence emission of Rhodamine 6G (R6G) and Acriflavine dyes in PMMA polymer have been studied by changing the irradiation and exposure time of laser light to know the effect of this parameter. It was found that the fluorescence intensity decreases in the polymer samples doped dyes as the exposure time increases and then reaches stabilization at long times, this behavior called photobleaching, which have been shown in liquid phase less than solid phase. Using 2nd harmonic with wavelength 530 nm laser, the photobleaching effect in the two dye-doped polymers different solvent but same was studied. It was observed that photobleaching of by different solution and by using dip spin coating the photobleaching seem in liquid phase
... Show MoreThe present study aims to investigate the long-term histopathological, and physiological effects of different concentrations of a commercially available energy drink (Tiger) on liver and kidney of young mice. Sixteen Balb/c male mice,6 -week old, were divided into 4 groups (n=4). Two groups consumed the energy drink at a concentration of 28µl energy drink/ml water. One group were killed after 10 days (T1), another group were killed after 20 days (T2). Other group of mice consumed the energy drink at a final concentration of 14µl/ml for 20 days (T3). The last group was provided only with water and served as control. Mice of all groups drank around 3 ml per day. The histopathological study on liver of treated groups showed many changes s
... Show MoreIn addition to the primary treatment, biological treatment is used to reduce inorganic and organic components in the wastewater. The separation of biomass from treated wastewater is usually important to meet the effluent disposal requirements, so the MBBR system has been one of the most important modern technologies that use plastic tankers to transport biomass with wastewater, which works in pure biofilm, at low concentrations of suspended solids. However, biological treatment has been developed using the active sludge mixing process with MBBR. Turbo4bio was established as a sustainable and cost-effective solution for wastewater treatment plants in the early 1990s and ran on minimal sludge, and is easy to maintain. This
... Show MoreObjectives: The study intends to identify the sources of work-related stress that might face the nurses working at
psychiatric wards in Baghdad psychiatric hospitals and to find out a relationship between the levels of stress and
some demographic characteristics.
Methodology: A descriptive study was achieved from the 10th of December, 2013 through the 10th of March, 2014.
Non-probability purposive samples of 94 nurses who work in psychiatric wards of Baghdad psychiatric hospitals
were recruited to meet the study objectives. Psychological Stress Inventory (PSI) the Arabic version, which was
modified by Abu Al-Hussein (2010) (20), was used. Data were analyzed by using the statistical analysis program of
SPSS 19th versi
A new concrete rheometer is introduced including its innovation, actual design, working rules,
calibration, and reliability. A modified design of Tattersall two-point device is created. Some of
components are purchased from local and foreign markets, while other components and the
manufacturing process are locally fabricated. The matching viscosity method of determining the mixer
viscometer constants is demonstrated and followed to relate torque and rotational speed to yield stress
and viscosity (Bingham parameters). The calibration procedures and its calculation are explained.
Water is used as a Newtonian fluid, while; cement paste (cement + water) with w/c ratio equal to
(0.442) is used as a non-Newtonian fluid. Th
The study included the collection of samples of raw cow milk to isolate Leuconostoc bacteria, samples were sub cultured on De-Man Rogosa Sharpe-Vancomycin medium, the pure colonies were selected and subjected to the cultural and microscopically tests, according to that 25 cocci bacterial isolates were obtained, then isolates were subjected to biochemical tests. Result of tests showed that 12 isolates belong to the genus Leuconostoc out of 25 cocci bacterial isolates, Vitek2 system was used as a supplementary step. Results of final identification showed that 3 sub species were obtained included Leuconostoc mesenteroides ssp. cremoris 9 out of 12 isolates, while it was 2 isolates of Leuconostoc mesenteroides ssp. mesenteroides and one isol
... Show MoreThe current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l
... Show More