In the early 90s military operations and United Nations Special Commission “UNSCOM” teams have been destroyed the past Iraqi chemical program. Both operations led an extensive number of scattered remnants of contaminated areas. The quantities of hazardous materials, incomplete destructed materials, and toxic chemicals were sealed in two bunkers. Deficiency of appropriate destruction technology led to spreading the contamination around the storage site. This paper aims to introduce the environmental detection of the contamination in the storage site area using geospatial analysis technique. The environmental contamination level of nutrients and major ions such as sulphate (SO4), potassium (K), sodium (Na), magnesium (Mg), calcium (Ca), chlorine (Cl), phosphate (PO4) and nitrate (NO3) were detected and analyzed. The grid soil samples on the site and surrounding areas have been investigated, analyzed, and compared to the background points. The storage area grid was divided into 30 major sectors and all samples were evaluated from acquires 10 samples from each sector. The detection results have indicated that SO4 level was exceeded the permitted level by 25 times, K level also exceeded the permitted level but by 460, Na ions were 85 times greater the permitted level. Mg level was 180 times higher than that of permitted content. Activity level of Ca in the soil samples of the study area has also exhibited variability with nine times over the permitted level near the bunkers. However, very high contamination spot activity of Cl was found in destruction zone about which 44 times over the background level was found while PO4 level exceeded the permitted level by 35 times over the permitted level and there was no activity detected for the nitrate in the storage area site.
The aim of human lower limb rehabilitation robot is to regain the ability of motion and to strengthen the weak muscles. This paper proposes the design of a force-position control for a four Degree Of Freedom (4-DOF) lower limb wearable rehabilitation robot. This robot consists of a hip, knee and ankle joints to enable the patient for motion and turn in both directions. The joints are actuated by Pneumatic Muscles Actuators (PMAs). The PMAs have very great potential in medical applications because the similarity to biological muscles. Force-Position control incorporating a Takagi-Sugeno-Kang- three- Proportional-Derivative like Fuzzy Logic (TSK-3-PD) Controllers for position control and three-Proportional (3-P) controllers for force contr
... Show MoreIn the field of civil engineering, the adoption and use of Falling Weight Deflectometers (FWDs) is seen as a response to the ever changing and technology-driven world. Specifically, FWDs refer to devices that aid in evaluating the physical properties of a pavement. This paper has assessed the concepts of data processing, storage, and analysis via FWDs. The device has been found to play an important role in enabling the operators and field practitioners to understand vertical deflection responses upon subjecting pavements to impulse loads. In turn, the resultant data and its analysis outcomes lead to the backcalculation of the state of stiffness, with initial analyses of the deflection bowl occurring in conjunction with the measured or assum
... Show MoreIn this study, the effect of the thermal conductivity of phase change material (PCM) on the performance of thermal energy storage has been analyzed numerically. A horizontal concentric shell-and-tube latent heat thermal energy storage system (LHTESS) has been performed during the solidification process. Two types of paraffin wax with different melting temperatures and thermal conductivity were used as a PCM on the shell side, case1=0.265W/m.K and case2=0.311 W/m.K. Water has been used as heat transfer fluid (HTF) flow through in tube side. Ansys fluent has been used to analyze the model by taking into account phase change by the enthalpy method used to deal with phase transition. The numerical simulatio
... Show MoreAn experiments were carried out at the College of Veterinary Medicine, University of Baghdad, during the period from October 26th 2023 to December 20th 2023, to study the effect of pasteurizing treatments of shell table egg using traditional Microwave oven on its quality characteristics during Zero, 1, 2, 4 and 8 weeks of refrigerator storage. A total of 120 fresh table eggs (White shell eggs) were collected from 20000 Luhman layer hens flock at Al-Amir project commercial farm, Al-Musaib city. These eggs were divided into 4 treatment of microwave pasteurization treatments which were Zero, 10, 20, and 30 sec. Results revealed that significant differences (P<0.05) for the internal characteristics of the egg after storage for 2, 4
... Show MoreExperiments were carried out at the College of Veterinary Medicine, University of Baghdad, during the period from October 26th 2023 to December 20th 2023, to study the effect of pasteurizing treatments of shell table egg using traditional Microwave oven on its quality characteristics during Zero, 1, 2, 4 and 8 weeks of refrigerator storage. A total of 120 fresh table eggs (White shell eggs) were collected from 20000 Luhman layer hens flock at Al-Amir project commercial farm, Al-Musaib city. These eggs were divided into 4 treatment of microwave pasteurization treatments which were Zero, 10, 20, and 30 sec. Results revealed that the numbers of total bacteria and total coliform on the surface of table egg shells is affected by pasteuri
... Show MoreIn this paper, three types of epoxy-based coatings (Polyamide, pure Polyamine, and Polyamine reinforced by glass-flake) used as a lining for potable water tanks were studied using experimental and finite element methods. Tensile, impact, and fatigue tests were conducted on uncoated and coated AISI 316 stainless steel. The test results show that the applied epoxy based coating improves the mechanical properties, increases of fatigue crack resistance, and enhance the dynamic fracture toughness. The fatigue crack propagation is influenced by the compositions of epoxy coating, and the glass-flake improves the coating resistance to fatigue crack propagation compared to other types.