In this study, ultraviolet (UV), ozone techniques with hydrogen peroxide oxidant were used to treat the wastewater which is produced from South Baghdad Power Station using lab-scale system. From UV-H2O2 experiments, it was shown that the optimum exposure time was 80 min. At this time, the highest removal percentages of oil, COD, and TOC were 84.69 %, 56.33 % and 50 % respectively. Effect of pH on the contaminants removing was studied in the range of (2-12). The best oil, COD, and TOC removal percentages (69.38 %, 70 % and 52 %) using H2O2/UV were at pH=12. H2O2/ozone experiments exhibited better performance compared to the H2O2/UV experiments. The results showed that 20 min was the best exposure time with removal percentages of 89.79 %, 83.33 % and 70% for oil, COD and TOC, respectively, and the optimum value of pH was at pH=8, where the pollutants removal percentages (i.e. 74.48 %, 80 % and 73.33 % respectively for the same previous pollutants). H2O2/ozone experiments showed better removal efficiency than the H2O2/UV experiments.
In the present work the performance of semifluidized bed adsorber was evaluated for removal of phenolic compound from wastewater using commercial activated carbon as adsorbent. P-chlorophenol (4-Chlorophenol) and o-cresol (2-methylphenol) was selected as a phenolic compound for that purpose. The phenols percent removal, in term of breakthrough curves were studied as affected by hydrodynamics limitations which include minimum and maximum semifluidization velocities and packed bed formation in the column by varying various parameters such as inlet liquid superficial velocity (from Uminsf to 8Uminsf m/s), and retaining grid (sometimes referred to as adsorbent loading) to initial static bed height ratio (from 3-4.5). In
... Show MoreAbstract
In light of the great technological development and the emergence of globalization has increased global competition, where it became competitive exercise pressure on all sectors. In light of this companies mast enviorment depend on the means that keeps them on the competitive position through access to information about competitors in order to help them to draw a strategy that will achieve a competitive edge either through excellence or reduce the costs of their products and this means intelligence competitive and reverse engineering that help to gain information on competitors analyze and put of the decision-maker From this point formed the idea of research in the statement of the role of
... Show MoreFinancial institutions, including banks, remain a major target for money launderers in order to transfer illegal funds to legitimate funds through limited internal audit procedures and external auditing.
The study is a study of the operations of money laundering and what can be done by the verification efforts when integrated in the fight against them, by analyzing the level of cooperative relationship and communication between them. To achieve the objectives of the study, a questionnaire prepared for this purpose was distributed to an appropriate sample of (60) auditors of the internal audit staff of the Central Bank of Iraq and the external auditors working in the Federal control foundation Accordingly , appropriate methods wer
... Show MoreThe security of information represent the available protection of information and its component and guaranty the its safety and confidentiality. The absent or lack or stop of security of information and without maximum benefit may lead to lose confidence and make it burden on the company. So we must protect the company and information from the damages which may lead to the frailer of performance and loses of the company and its workers. So the security of information considered one of the potential and controlling basis to protect individuals and companies from the damages. To insure the security and confidentiality of information there are delicate, proper and trusted ways, like FIRE WALL, PASS WORD, SYPHAR
... Show MoreThis study was concerned with using ozone gas in drinking water treatment plant at Ibn-Sina Company. The main purpose of this research is to find the best contactor for ozone unit proposed. An investigation was conducted to study the absorption of ozone by water in two type of absorber. The effects of the process variables (such as height of water column, contact time, and pH) on the amount of ozone absorbed were investigated. Box-Wilson central composite rotatable design is used to design the experimental work for the mentioned variables. It was found that the optimum value of the variables studied was:
i) Height of water column (90 cm)
ii) Contact time (17-18 min)
iii) PH (7 - 7.5)
The mediation system is based on settling the dispute amicably through the intervention of a third party by bringing views closer away from the judiciary, which is an amicable way to settle disputes, which disputants resort to voluntarily, but some Western legislation has begun to impose resorting to mediation to settle disputes compulsorily, to take advantage of its advantages, get rid of the disadvantages of resorting to the judiciary in some disputes, and relieve pressure on the courts.
The research problem boils question is there in Riyadh organizational climate that enables them to do their work properly and whether there are differences between the government and private Riyadh depending on the organizational climate has sought Find measure: 1 regulatory climate for kindergarten 2. The difference between government and private Riyadh depending on the organizational climate. Limited research on the (200) parameter of the Riyadh government and private parameters for the year (20,142,015) In order to achieve the research objectives the researchers built a regulatory climate in accordance with the scientific steps to build a psychological scales measure After the formulation of climate regulation paragraphs of the (30) p
... Show MoreWater quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their perfor
... Show MoreIn this study, field results data were conducted, implemented in 64 biofilm reactors to analyses extract organic matter nutrients from wastewater through a laboratory level nutrient removal process, biofilm layer moving process using anaerobic aerobic units. The kinetic layer biofilm reactors were continuously operating in Turbo 4BIO for BOD COD with nitrogen phosphorous. The Barakia plant is designed to serve 200,000 resident works on biological treatment through merge two process (activated sludge process, moving bed bio reactio MBBR) with an average wastewater flow of 50,000 m3/day the data were collected annually from 2017-2020. The water samples were analysis in the central labor
Water quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their performance is evaluated usin
... Show More