To ensure fault tolerance and distributed management, distributed protocols are employed as one of the major architectural concepts underlying the Internet. However, inefficiency, instability and fragility could be potentially overcome with the help of the novel networking architecture called software-defined networking (SDN). The main property of this architecture is the separation of the control and data planes. To reduce congestion and thus improve latency and throughput, there must be homogeneous distribution of the traffic load over the different network paths. This paper presents a smart flow steering agent (SFSA) for data flow routing based on current network conditions. To enhance throughput and minimize latency, the SFSA distributes network traffic to suitable paths, in addition to supervising link and path loads. A scenario with a minimum spanning tree (MST) routing algorithm and another with open shortest path first (OSPF) routing algorithms were employed to assess the SFSA. By comparison, to these two routing algorithms, the suggested SFSA strategy determined a reduction of 2% in packets dropped ratio (PDR), a reduction of 15-45% in end-to-end delay according to the traffic produced, as well as a reduction of 23% in round trip time (RTT). The Mininet emulator and POX controller were employed to conduct the simulation. Another advantage of the SFSA over the MST and OSPF is that its implementation and recovery time do not exhibit fluctuations. The smart flow steering agent will open a new horizon for deploying new smart agents in SDN that enhance network programmability and management.
The research focuses on how to reach a mechanism that assists experts, engineers, and others in the architectural & engineering project to verify the co-existence of values and sustainability constituents in it. Research problem shows a clear lack, locally, in the interest to establish a value system and a list that cares about comprehending building components whether considering sustainable building criteria. Hypothesis shows that in order to head towards the applicable sustainable approach of buildings, then a local assessment system should be established to evaluate buildings during its life cycle, and from which buildings would be categorized as sustainable or not. Research aims at establishing main and general
... Show MoreIron slag is a byproduct generated in huge quantities from recycled remnants of iron and steel factories; therefore, the possibility of using this waste in the removal of benzaldehyde from contaminated water offers an excellent topic in sustainability field. Results reveal that the removal efficiency was equal to 85% for the interaction of slag and water contaminated with benzaldehyde at the best operational conditions of 0.3 g/100 mL, 6, 180 min, and 250 rpm for the sorbent dosage, initial pH, agitation time, and speed, respectively with 300 mg/L initial concentration. The maximum uptake capacity of iron slag was 118.25 mg/g which was calculated by the Langmuir model. Physical sorption may be the major mechanism for the removal of
... Show MoreObjectives: To assess the level of dependence severity, locus of control, and readiness to change in male alcohol clients and measure the correlation between dependence with a locus of control and readiness to change.
Methodology: A descriptive correlational design was conducted in the substance use rehabilitation centers at psychiatric teaching hospitals in Baghdad city from November /2021 to May 2022. The instrument of the study was designed by using sociodemographic, the clinical characteristics of the client, the Short-form Alcohol Dependence Data Questionnaire (SADD), Drinking Related Internal-External Locus of Control Scale: (DRIE), and the Stages of Change Readiness and Treatment Eagerness Scale (SOCRATES). The data was co
... Show MoreSteady natural convection in a square enclosure with wall length (L= 20 cm) partially filled by saturated porous medium with same fluid (lower layer) and air (upper layer) is investigated. The conceptual study of the achievements of the heat transfer is performed under effects of bottom heating by constant heat flux (q=150,300,450,600W/m2 ) for three heaters size (0.2,0.14,0.07)m with symmetrically cooling with constant temperature on two vertical walls and adiabatic top wall. The relevant filled studied parameters are four different porous medium heights (Hp=0.25L,0.5L, 0.75L, L), Darcey number (Da1) 3.025×10-8 and (Da2) 8.852×10-4 ) and Rayleigh number range (60.354 - 241.41), (1.304×106 – 5.2166×106 ) for Da1 and Da2 cases respecti
... Show MoreIt has become clear to see the role of the small and medium enterprises in the economy, and for the continuity of these projects it is necessary to supply finance from the banks, How ever the latter suffers risk of lending.
&n
... Show MoreBackground: Lead-acid battery workers are at higher risk for systemic diseases as well as oral diseases like dental caries. The aim of this study was to assess selected salivary antioxidants and their relation with dental caries among lead acid battery factory workers in comparison with non-exposed group. Materials and methods: The sample consisted of 35 subjects aged 35-45 year-old who worked in Babylon lead acid battery factory in Baghdad city and matching group that not exposed to lead were selected as a control. Dental caries severity was recorded by using DMFS index, stimulated salivary samples were collected and analyzed for the measurement of salivary antioxidants (uric acid, total protein, catalase and glutathione peroxidase enzymes
... Show More