The varied thermal conductivity (insulation) of silica aerogel with heating for different pH has been investigated, it has been depended on ambient pressure drying method in the preparing silica aerogel samples, also six different pH of samples (1, 2, 3, 7, 8 and 9) were treated under five degree of heating with (50,100,150,200 and 250) ᴼC. This technique is important to test the carry-outs hydrophobic silica to temperature without high-quality material changes in the basic characteristics. The hot-wire technique is used in this work to examine the thermal conductivity, Fourier Transform Infrared Spectroscopy (FTIR) depended to characterize the bonds and their artificial by heating. Results show that the samples affected by heating through decreasing the density leading to obtaining more insulation metal, moreover varied pH is an important role in thermal conductivity. The average thermal conductivity of all aerogel samples in this work is (0.01- 0.0061 mW m-10 C-1) this means that it is still below thermal conductivity for air equals to (0.02257) mW m-10 C-1 . Meanwhile, we concluded that the insulation property of silica aerogel is affected by heat treatment and gives it more thermal insulation property.
The performance of composite prestressed concrete beam topped with reinforced concrete flange structures in fire depends upon several factors, including the change in properties of the two different materials due to fire exposure and temperature distribution within the composition of the composite members of the structure. The present experimental work included casting of 12 identical simply supported prestressed concrete beams grouped into 3 categories, depending on the strength of the top reinforced concrete deck slab (20, 30, and 40 MPa). They were connected together by using shear connector reinforcements. To simulate the real practical fire disasters, 3 composite prestressed concrete beams from each group were exposed to high t
... Show MoreLiquefied petroleum gases (LPG) consist of hydrocarbons obtained by refining crude oil, either from propane or butane or a mixture of the two. There are often other components such as propylene, butylene or other hydrocarbons, but they are not the main component. The study aims to review previous studies dealing with designing an LPG system to deliver gas to residential campuses and buildings. LPG is extracted from natural gas NG by several processes, passing through fractionation towers and then pressuring into CNG storage tanks. Gas contains several problems, including gas leakage through the pipes and leads to fires or explosions in LPG storage and distribution tanks, so safety conditions were taken in the design and implementation. T
... Show MoreThe sustainable development according to the United Nation, listed firms throughout globally now routinely provide sustainability data. However, there is not enough information on Sustainability Performance Quality (SPQ) in the majority of emerging economies, including Malaysia. This study looks at how the SPQ of the top 100 Malaysian-listed businesses is affected by factors as connected with corporate governance (e.g., board meeting, board size, and board ethnic diversity). Utilizing 500 firm-year data, a longitudinal sample of 500 nonfinancial firms on the Bursa Malaysia for 2015-2019 is employed in this study. The findings from the analysis using the panel regression demonstrated that: ethnic diversity and board siz
... Show MoreImage compression is a suitable technique to reduce the storage space of an image, increase the area of storage in the device, and speed up the transmission process. In this paper, a new idea for image compression is proposed to improve the performance of the Absolute Moment Block Truncation Coding (AMBTC) method depending on Weber's law condition to distinguish uniform blocks (i.e., low and constant details blocks) from non-uniform blocks in original images. Then, all elements in the bitmap of each uniform block are represented by zero. After that, the lossless method, which is Run Length method, is used for compressing the bits more, which represent the bitmap of these uniform blocks. Via this simple idea, the result is improving
... Show MoreThis study was conducted in the Department of Employment and Loans at the Ministry of Labor and Social Affairs to indicate the importance and impact of both the empowerment and the functional flexibility in evaluating the performance of the employees. To achieve the objectives of the study, the data was collected through a questionnaire form designed for this purpose based on previous studies. Data obtained for a significant evaluation of the relationship between the components of both the empowerment and the functional flexibility with the components of the evaluation and determining the degree of importance of each component of both the empowerment and functional flexibility for the components of the evaluation by the extractio
... Show MoreThis paper proposes a novel finite-time generalized proportional integral observer (FTGPIO) based a sliding mode control (SMC) scheme for the tracking control problem of high order uncertain systems subject to fast time-varying disturbances. For this purpose, the construction of the controller consists of two consecutive steps. First, the novel FTGPIO is designed to observe unmeasurable plant dynamics states and disturbance with its higher time derivatives in finite time rather than infinite time as in the standard GPIO. In the FTGPO estimator, the finite time convergence rate of estimations is well achieved, whereas the convergence rate of estimations by classical GPIO is asymptotic and slow. Secondly, on the basis of the finite and fast e
... Show MoreThe systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are Conventional within this atmosphere of Iraq, and after taking different readings
... Show More