In this work, the fractional damped Burger's equation (FDBE) formula = 0,
A LiF (TLD-700) PTFED disc has adiameter of (13mm) and thickness of (0.4mm) for study the response and sensetivity of this material for gamma and beta rays by using (TOLEDO) system from pitman company. In order to calibrate the system and studying the calibration factor. Discs were irradiated for Gamma and Beta rays and comparing with the theoretical doses. The exposure range is between 15×10-2 mGy to 1000×10-2 mGy. These doses are within the range of normal radiation field for workers.
In this paper we investigate the automatic recognition of emotion in text. We propose a new method for emotion recognition based on the PPM (PPM is short for Prediction by Partial Matching) character-based text compression scheme in order to recognize Ekman’s six basic emotions (Anger, Disgust, Fear, Happiness, Sadness, Surprise). Experimental results with three datasets show that the new method is very effective when compared with traditional word-based text classification methods. We have also found that our method works best if the sizes of text in all classes used for training are similar, and that performance significantly improves with increased data.
Various methods are utilized providing complexity for cryptosystem with the aim to increase the security and avoiding hacker attack. Hybrid cryptosystem is one of these cryptosystems which is used two types of cryptosystems and has many applications in data transmitted. This research, proposed a novel method that used power exponent instead of using the prime number directly and also providing complexity of asymmetric cryptosystems. This method has been applied theoretically in two public systems RSA and EL-Gamal. Power RSA and Power EL-Gamal are modified asymmetric cryptosystems, in which the power number is kept by the sender and the receiver. Moreover, we use group theory to prove that these cryptosystems work properly. Our exten
... Show MorePsi prepared by Electrochemical etching technique at invariable etching current density of 10 mA/cm2 and at different times (7 and 17) min. The porous Si structure was studied using XRD, (FE-SEM) and EDS. The process of sensing NH3 gas is carried out at different operating temperatures (R.t,80,130 and 200)°C and the gas concentration is constant. It is measured by changing the resistance of the sensor as a function of exposure time to the gas. The result showed the XRD patterns of the PS at (7 and 17) min etching time. the peak samples at (111) around 2θ = 28.5°. It is observed that the peak intensity declines with rising the etching time,