This work reports the development of an analytical method for the simultaneous analysis of three fluoroquinolones; ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL) in soil matrix. The proposed method was performed by using microwave-assisted extraction (MAE), solid-phase extraction (SPE) for samples purification, and finally the pre-concentrated samples were analyzed by HPLC detector. In this study, various organic solvents were tested to extract the test compounds, and the extraction performance was evaluated by testing various parameters including extraction solvent, solvent volume, extraction time, temperature and number of the extraction cycles. The current method showed a good linearity over the concentration ranging from 1 – 300ng g-1 with correlation coefficients (r2 > 0.998) for all test compounds. Good recoveries were also obtained for the test compounds ranged from 89 – 99 %. The relative standard deviation (RSD) from intra-day and inter-day precision was lower than 7%, and the detection (LOD) and quantification (LOQ) limits ranged from 0.9 – 2.7ng g-1.Finally, the proposed method was applied to determine the target compounds in real soil samples irrigated with wastewater. The results confirm the presence of the test compounds in soils with values ranging from 1.9 – 4.6ng g-1, as well as the suitability of the proposed method to determine the test compounds in real soil matrix as well as the ability of the test compounds to accumulate in soils irrigated with sewage.
This research describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc
The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar & reference divider in single chip. Therefore our system consists of a single chip contains (low phase noise PFD, charge pump, prescalar & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip
... Show MoreEach art has its own language. Per his style as an artist, which is characterized by the other. The methods differ and vary expressive art to another depending on the tools and methods used, and is a theatrical phenomenon did, and see, and touch, grasp, understand, and imagine, and emotion, and the blending of ideas and images. When unable to speak the language of the traditional theater For the delivery of a specific meaning or a single non-current at the time the highlight of our new language with a very wide area up to the extent of the unification of the languages of the world as it is in fine painting, it's the body of actor language, so it has become a mime art, which expressed Representative meanings reference and movement of vari
... Show MoreThe present study aimed to investigate the histological changes of heart, lung, liver and kidney which caused by different concentrations (10, 20 and 40 mg/kg) of Ivabradine. Results of the study revealed some histological changes represented by aggregation of the lymphocytes around respiratory bronchioles of the lung. In the liver, the drug caused hepatocyte necrosis and infiltration of the lymphocytes. In Kidney, there are no histopathological modifications in the tissue after the animals treated with 10 mg\kg of Ivabradine. When the animals treated with Ivabradine drug at 20mg/kg of bw, dose showed vascular congestion between myocardial fibers of heart. Emphysematous c
... Show MoreLinear discriminant analysis and logistic regression are the most widely used in multivariate statistical methods for analysis of data with categorical outcome variables .Both of them are appropriate for the development of linear classification models .linear discriminant analysis has been that the data of explanatory variables must be distributed multivariate normal distribution. While logistic regression no assumptions on the distribution of the explanatory data. Hence ,It is assumed that logistic regression is the more flexible and more robust method in case of violations of these assumptions.
In this paper we have been focus for the comparison between three forms for classification data belongs
... Show MoreBackground: Anemia is a common finding in patients with renal failure disease and it is, primarily, due to reduced production of iron and erythropoietin. Therefore, the aim of current study was to evaluate the relationship between serum level of hepcidin 25, on the one hand, and levels of serum iron, total iron-binding capacity, serum erythropoietin and transferrin saturation% in Iraqi male patients undrgoning haemodialysis.. Methods: Serum from75 males in the end stage of hemodialysis, as group one, and 25 Iraqi healthy malecontrols, as group two, were recruited in this study. Results: Data from current study showed significant increase in hepcidin 25 and significant decrease in serum iron, total iron-binding capacity, transferrin saturati
... Show MoreAbstract:
This study is studied one method of estimation and testing parameters mediating variables in a structural equations model SEM is causal steps method, in order to identify and know the variables that have indirect effects by estimating and testing mediation variables parameters by the above way and then applied to Iraq Women Integrated Social and Health Survey (I-WISH) for year 2011 from the Ministry of planning - Central statistical organization to identify if the variables having the effect of mediation in the model by the step causal methods by using AMOS program V.23, it was the independent variable X represents a phenomenon studied (cultural case of the
Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl
... Show More