Preferred Language
Articles
/
bsj-3185
Effects of Discharge Current and Target Thickness in Dc-Magnetron Sputtering on Grain Size of Copper Deposited Samples
...Show More Authors

A study of the effects of the discharge (sputtering) currents (60-75 mA) and the thickness of copper target (0.037, 0.055 and 0.085 mm) on the prepared samples was performed. These samples were deposited with pure copper on a glass substrate using dc magnetron sputtering with a magnetic flux density of 150 gauss at the center. The effects of these two parameters were studied on the height, diameter, and size of the deposition copper grains as well as the roughness of surface samples using atomic force microscopy (AFM).The results of this study showed that it is possible to control the specifications of copper grains by changing the discharge currents and the thickness of the target material. The increase in discharge current values ​​led to a decrease in height copper grain's values ​​of 20% at a current of 75 mA and target thickness of 0.085 mm. Furthermore, the increasing in the current caused a decrease in the diameter and size values of deposition copper grains. Finally, the surface roughness of the samples was reduced by a 15%  by changing the current and target material thickness at 75 mA and 0.085mm respectively.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 03 2012
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of Window Size Changing on Satellite Image Segmentation Using 2D Fast Otsu Method
...Show More Authors

Publication Date
Wed Jan 01 2025
Journal Name
E3s Web Of Conferences
Assessment of radiological biological risks in samples of medicinal plants in Iraq
...Show More Authors

The aim of this research sought to assess the background radiati on levels of medicinal plant samples in Iraq.The D, AED, and ELCRThe D values are 0.164 ± 0.006 µSv/h.The radiation dose outputs from the afore mentioned research were juxtaposed with the safety threshold of 0.247 µSv/h set by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2008 and the National Council on Radiation Pr otection and Measurements (NCRP) in 2009.The radiation exposure for all samples in this investigation is within the permissible limits.Additionally, t he AED values obtained from microsieverts per hour are (1.31 ±0.0326 mS v/y), indicating variability, with a maximum permissible limit of 2.4 mSv/y ear, as per t

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
The Streamer Discharge Propagation Within Normal Hexane and Acetone Liquids
...Show More Authors

Based on the streamer growth model, the streamer discharge propagation was simulated in aid of finite element technique. That was done within two non- mixed dielectric liquids (Normal-Hexane and Acetone) located between two electrodes in pin - plane configuration. The output results show that, the path of the streamer was affected by the interface between the two liquids; the streamer path crosses this interface under some conditions such as the permittivity of the liquids and the distance between this interface and the tip of the pin. Under other conditions, the streamer path grows along the interface. The results were assisted by the development of the potential and the electric field distributions with the growth of the streamer propa

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 11 2014
Journal Name
Pakistan Journal Of Biological Sciences
Effects of Local Curcumin on Oxidative Stress and Total Antioxidant Capacity in vivo Study
...Show More Authors

Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Estimation of Mass Transfer Coefficient for Copper Electrowinning Process
...Show More Authors

Mass transfer was examined at a stationary rectangular copper electrode (cathode) by using the reduction of cupric ions as the electrochemical reaction. The influence of electrolyte temperature (25, 45, and 65 oC), and cupric ions concentration (4, 8, and 12 mM) on mass transfer coefficient were investigated by using limiting current technique. The mass transfer coefficient and hence the Sherwood number was correlated as Sh =

 

View Publication Preview PDF
Publication Date
Sun Dec 01 2013
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The fair Value and its Using Effects on The Financial Reports Quality
...Show More Authors

This research aims at studying the relation between fair value and the Financial Reports Quality  to achieve a number of aims such as :-

1- Throw light on the problems of the measurement that depends on the historic cost as it paves the way towards the method of the fair value in the accounting measurement.

2-Give a general definition for  fair value in the accounting via analyzing the theoretical aspects that relates the subject and the  scientific bases on which the relating accounting treatment depend.

3- Exhibit the characteristics that could be added by the fair value  to the accounting Information .

       The study problem is summarized in that the e

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Biocatalysis And Agricultural Biotechnology
Determination of Diazinon in fruit samples using electrochemical sensor based on carbon nanotubes modified carbon paste electrode
...Show More Authors

View Publication
Scopus (52)
Crossref (47)
Scopus Crossref
Publication Date
Sat Sep 01 2018
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of the volume of Capital heldin stock prices: An analytical study in a sample of Iraqi banks listed in the Iraqi Stock Exchange
...Show More Authors

 The capital in the bank is the important element in establishing it, because it maintains the banking sector in the event of exposure to losses or risks In addition to contributing to the provision of liquidity And protection of depositors' money from potential and unexpected losses. There is also a relationship between the prices of shares and the indicators of the durability of the capital owned, considering that the shares are the components of the bank capital The study limited the indicators of capital to assets and capital to deposits, capital to loans and financial investments Where the most important conclusions are the damage to the detriment of shareholders in contrast to the depositors in the case of increasing the propo

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (12)
Scopus Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center

... Show More
Scopus (13)
Crossref (12)
Scopus Crossref