Preferred Language
Articles
/
bsj-3185
Effects of Discharge Current and Target Thickness in Dc-Magnetron Sputtering on Grain Size of Copper Deposited Samples
...Show More Authors

A study of the effects of the discharge (sputtering) currents (60-75 mA) and the thickness of copper target (0.037, 0.055 and 0.085 mm) on the prepared samples was performed. These samples were deposited with pure copper on a glass substrate using dc magnetron sputtering with a magnetic flux density of 150 gauss at the center. The effects of these two parameters were studied on the height, diameter, and size of the deposition copper grains as well as the roughness of surface samples using atomic force microscopy (AFM).The results of this study showed that it is possible to control the specifications of copper grains by changing the discharge currents and the thickness of the target material. The increase in discharge current values ​​led to a decrease in height copper grain's values ​​of 20% at a current of 75 mA and target thickness of 0.085 mm. Furthermore, the increasing in the current caused a decrease in the diameter and size values of deposition copper grains. Finally, the surface roughness of the samples was reduced by a 15%  by changing the current and target material thickness at 75 mA and 0.085mm respectively.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Effect of Magnesium Addition on Corrosion Resistance of Aluminum -17%Silicon Alloy
...Show More Authors

The electrochemical behavior of Al-17%Si alloy is investigated in 3.5wt% NaCl solution. Many alloys with addition of the different wt% magnesium metal of  1wt%, 2%, 3wt% ,4.5wt% ,and 9wt% were prepared by gravity die casting . The microstructures of prepared alloys were examined by optical and SEM microscopes. Corrosion behavior was investigated by using potentiostat instrument under static potentials test and corrosion current was recorded to determine corrosion resistance of all prepared samples. It was found that the addition of Mg metal improves the corrosion resistance of Al-17%Si alloy in 3.5%NaCl solution. The alloy containing 1%Mg shows less corrosion rate than the others while the alloys containing 4.5%Mg, 9%Mg content have

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Sep 04 2018
Journal Name
Al-khwarizmi Engineering Journal
Effect of Carburization Parameters on Hardness of Carburized Steel Using MOORA Approach
...Show More Authors

In this research, (MOORA) approach based– Taguchi design was used to convert the multi-performance problem into a single-performance problem for nine experiments which built (Taguchi (L9) orthogonal array) for carburization operation. The main variables that had a great effect on carburizing operation are carburization temperature (oC), carburization time (hrs.) and tempering temperature (oC). This study was also focused on calculating the amount of carbon penetration, the value of hardness and optimal values obtained during the optimization by Taguchi approach and MOORA method for multiple parameters. In this study, the carburization process was done in temperature between (850 to 950 ᵒC) for 2 to 6

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Oct 07 2016
Journal Name
Fourth International Conference On Wireless And Optical Communications, 2016, Beijing, China
ESAM: Endocrine inspired Sensor Activation Mechanism for multi-target tracking in WSNs
...Show More Authors

Target tracking is a significant application of wireless sensor networks (WSNs) in which deployment of self-organizing and energy efficient algorithms is required. The tracking accuracy increases as more sensor nodes are activated around the target but more energy is consumed. Thus, in this study, we focus on limiting the number of sensors by forming an ad-hoc network that operates autonomously. This will reduce the energy consumption and prolong the sensor network lifetime. In this paper, we propose a fully distributed algorithm, an Endocrine inspired Sensor Activation Mechanism for multi target-tracking (ESAM) which reflecting the properties of real life sensor activation system based on the information circulating principle in the endocr

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Crossref
Publication Date
Sun May 30 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology,
Effect of Diabetes and Hypertension on Right Carotid Artery Intima Media Thickness and Variable Spectral Waveform Indices And Parameters in Relation To Age for Iraqi Patients
...Show More Authors

Background: Arterial stiffness is related with atherosclerosis and cardiovascular disease events. Patients with atherosclerotic disease show to have larger diameters, reduced arterial compliance and lower flow velocities. Aim of study : To compare between patients of two age groups with concomitant diseases diabetes and hypertension in regard to intima media thickness and blood flow characteristics in order to estimate the blood perfusion to the brain via the common and internal carotid arteries. Subject and Methods : 40 patients with (diabetic and hypertension) diseases were enrolled , they were classified according to age. Color Doppler and B mode ultrasound was used to determine lumen Diameter (D), Intima – media thickness (IMT)

... Show More
Scopus (1)
Scopus
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Thermoelectric power for thermally deposited cadmium telluride films
...Show More Authors

Thermal evaporation method has used for depositing CdTe films
on corning glass slides under vacuum of about 10-5mbar. The
thicknesses of the prepared films are400 and 1000 nm. The prepared
films annealed at 573 K. The structural of CdTe powder and prepared
films investigated. The hopping and thermal energies of as deposited
and annealed CdTe films studied as a function of thickness. A
polycrystalline structure observed for CdTe powder and prepared
films. All prepared films are p-type semiconductor. The hopping
energy decreased as thickness increased, while thermal energy
increased.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Threshold Current Density of Al0.1Ga0.9N/GaN Triple Quantum Well Laser
...Show More Authors

Semiconductor laser is used in processing many issues related to the scientific, military, medical, industrial and agricultural fields due to its unique properties such as coherence and high strength where GaN-based components are the most efficient in this field. Current technological developments mention to the strong connection of GaN with sustainable electronic and optoelectronic devices which have high-efficiency. The threshold current density of Al0.1Ga0.9N/GaN triple quantum well laser structure was investigated to determine best values of the parameters affecting the threshold current density that are well width, average thickness of active region, cavity length, reflectivity of cavity mirrors and optical confinement factor. The opt

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Mar 15 2021
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Educational Program on Nursing Staffs' Knowledge about Uses of Steroids and Their Side Effects in Al-Diwaniya Teaching hospital
...Show More Authors

Objective: To determine the effectiveness of the educational program on nursing staffs' knowledge about uses of steroids and their side effects.
Methodology: A pre-experimental study design (one group design: pre-test and post-test) was used. This study was conducted in Al-Diwaniya Teaching Hospital for the period from ( 28th May to 10 th June, 2020) on a non-probability (purposive) sample consisting of (30 nurses) working in Oncology unit. A questionnaire was built as a data collection tool and consisted of two parts:
First part: The demographic characteristics of the nursing staff (gender, age, level of education, years of experience in hospital, participation in training courses related to nursing care for a patients undergoing

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 15 2021
Journal Name
Iraqi National Journal Of Nursing Specialties
Effect of Pioneer Aeromedical Evacuation Program on Flight Medics' Knowledge toward Emergency Casualties at Army Aviation Bases in Iraq
...Show More Authors

Objective(s): The aims of present study to findout the effect of aeromedical evacuation program on flight medics’ knowledge.
Methods: A pre-experimental design is carried in army aviation bases in Iraq, for the period of April 1st 2019 to October 25th 2019. Non-probability "purposive" sample of (30) flight medics are selected from army aviation bases. The questionnaire consisted of two main parts: the demographic characteristics of air paramedics, and the second part included five axes, which are (50) paragraphs related to the knowledge of air paramedics towards emergency injuries. The researcher used the statistical program version 20 to analyze the data, and the stability of the questionnaire was measured through the pre and post

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 11 2014
Journal Name
Pakistan Journal Of Biological Sciences
Effects of Local Curcumin on Oxidative Stress and Total Antioxidant Capacity in vivo Study
...Show More Authors

Publication Date
Wed Jan 01 2025
Journal Name
E3s Web Of Conferences
Assessment of radiological biological risks in samples of medicinal plants in Iraq
...Show More Authors

The aim of this research sought to assess the background radiati on levels of medicinal plant samples in Iraq.The D, AED, and ELCRThe D values are 0.164 ± 0.006 µSv/h.The radiation dose outputs from the afore mentioned research were juxtaposed with the safety threshold of 0.247 µSv/h set by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2008 and the National Council on Radiation Pr otection and Measurements (NCRP) in 2009.The radiation exposure for all samples in this investigation is within the permissible limits.Additionally, t he AED values obtained from microsieverts per hour are (1.31 ±0.0326 mS v/y), indicating variability, with a maximum permissible limit of 2.4 mSv/y ear, as per t

... Show More
View Publication
Scopus Crossref