Preferred Language
Articles
/
bsj-3052
Biomarker Significance of Serum CXCL8, CXCL10 and CXCL16 in Breast Tumors of Iraqi Patients
...Show More Authors

The biomarker significance of three chemokines (CXCL8, CXCL10 and CXCL16) was evaluated in sera of 45 breast cancer (BC) and 28 benign breast lesion (BBL) patients, as well as 20 control women. Clinical stage and tumor expression of estrogen (ER), progesterone (PgR) and human epidermal growth factor receptor-2 (HER-2) receptors were considered in this evaluation. The results demonstrated that CXCL8, CXCL10 and CXCL16 showed a significant increased median in BC and BBL patients compared to control (CXCL8: 47.3 and 25.7 vs. 15.0; CXCL10: 37.6 and 30.7 vs. 13.1; CXCL16; 27.9 and 25.2 vs. 19.2 pg/ml, respectively). The increased levels of CXCL8 and CXCL16 were more pronounced in triple-negative and HER-2 positive patients, respectively. Binary logistic regression analysis revealed that CXCL8 was a significant predictor of BC, and such prediction was more depicted in triple-negative patients. The receiver operating characteristic analysis also revealed that CXCL8 recorded an area under curve of 0.998 in BC patients. In conclusion, CXCL8 is a potential biomarker for BC, especially when ER, PgR and HER-2 expression is considered. In this context, the predictive significance of CXCL8 in influencing BC progression is suggested in triple-negative patients.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Optik
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355 nm for sensing NH3 gas
...Show More Authors

a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn

... Show More
View Publication
Scopus (39)
Crossref (34)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Pharmaceutical Research
New method for the evaluation of propranolol with phosphotungstic acidvialong distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis
...Show More Authors

A new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the

... Show More
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Fri May 01 2026
Journal Name
Results In Chemistry
Advanced spectrofluorimetric determination of ascorbic acid via serotonin hydrochloride quenching using a twin solar cell device with eight-angled blue radiation sources
...Show More Authors

novel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Computational Biology And Chemistry
A graph-based multi-sample test for identifying pathways associated with cancer progression
...Show More Authors

Cancer is in general not a result of an abnormality of a single gene but a consequence of changes in many genes, it is therefore of great importance to understand the roles of different oncogenic and tumor suppressor pathways in tumorigenesis. In recent years, there have been many computational models developed to study the genetic alterations of different pathways in the evolutionary process of cancer. However, most of the methods are knowledge-based enrichment analyses and inflexible to analyze user-defined pathways or gene sets. In this paper, we develop a nonparametric and data-driven approach to testing for the dynamic changes of pathways over the cancer progression. Our method is based on an expansion and refinement of the pathway bei

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Jun 09 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
G Protein-Coupled Receptors: Undervalued Targets for Cancer Therapy
...Show More Authors

Despite the G protein-coupled receptors (GPCRs) being the largest family of signalling proteins at the surface of cells, their potential to be targeted in cancer therapy is still under-utilised. This review highlights the contribution of these receptors to the process of oncogenesis and points to some likely challenges that might be encountered in targeting them. GPCR-signalling pathways are often complex and can be tissue-specific. Cancer cells hijack these communication networks to their proliferative advantage. The role of selected GPCRs in the different hallmarks of cancer is examined to highlight the complexity of targeting these receptors for therapeutic benefit. Our

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jan 02 2020
Journal Name
Arab Science Heritage Journal
الظاهرة اللغوية بين الوص ف والتفسير أث ر المفاهي م الكل ي ة في التوفيق بين الاتجاهين العقلاني والطبيعي في دراس ة اللغ ة البشرية
...Show More Authors

This research investigates modern linguistics in terms of the “universality” concept, through which linguistics shifted its attention from the description of the phenomenon into finding an interpretation of it. Then it investigates what needs interpretation in the language

View Publication Preview PDF
Publication Date
Thu Jan 02 2020
Journal Name
Arab Science Heritage Journal
الظاهرة اللغوية بين الوص ف والتفسير أث ر المفاهي م الكل ي ة في التوفيق بين الاتجاهين العقلاني والطبيعي في دراس ة اللغ ة البشرية
...Show More Authors

This research investigates modern linguistics in terms of the “universality” concept, through which linguistics shifted its attention from the description of the phenomenon into finding an interpretation of it. Then it investigates what needs interpretation in the language

View Publication Preview PDF
Publication Date
Tue May 28 2024
Journal Name
وزارة التخطيط/الجهاز المركزي للتقييس والسيطرة النوعية
تحضير , تشخيص , دراسة السمية والفعالية ضد خلايا سرطان ‏الرئة لمركبات حلقية غير ‏متجانسة جديدة ومعقداتها الفلزية النانوية
...Show More Authors

‏ يهدف البحث إلى تحضير سلسلة جديدة من معقدات العناصر الانتقالية ثنائية التكافؤ (الكوبلت, النيكل, النحاس, الخارصين ‏‏,الكادميوم والزئبق) مع المركبات الحلقية غير المتجانسة (‏L1‎‏) و(‏L2‎‏) والمشتقة من تفاعل 2,1- فينيلين ثنائي امين ‏وسايكلوهكسان -2,1-ثنائي امين مع المركب الوسطي (‏Pr‏) على التوالي. شخصت المعقدات ذات الصيغة العامة :-‏ ‏ ‏‎[M(L1or L2)Cl2]‎‏ بواسطة طيف الرنين النووي المغناطيسي البروتوني والكربوني وقيا

... Show More
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Laser
Experimental Study to The Effect of Applying Stressing Force on Etched Polarization Maintaining Fiber as Hybrid Fabry-Perot /Mach-Zehnder inline fiber interferometer
...Show More Authors

Abstract: The increased interest in developing new photonic devices that can support high data rates, high sensitivity and fast processing capabilities for all optical communications, motivates a pre stage pulse compressor research. The pre-stage research was based on cascading single mode fiber and polarization maintaining fiber to get pulse compression with compression factor of 1.105. The demand for obtaining more précised photonic devices; this work experimentally studied the behavior of Polarization maintaining fiber PMF that is sandwiched between two cascaded singe mode fiber SMF and fiber Bragg gratings FBG. Therefore; the introduced interferometer performed hybrid interference of both Mach-Zehnder

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 21 2025
Journal Name
Journal Of University Of Anbar For Pure Science
Semi – automated analysis for the Nanoscale determination of Chlorpheniramine maleate drug using sodium nitroprusside by continuous flow feed via homemade NAG-SSP Photometer
...Show More Authors

This study presents a rapid, sensitive, and straightforward approach to measure chlorpheniramine maleate (CPM) by using turbidity CFIA. The method involves CPM reacting with sodium nitroprusside (Nitropress) to produce a pale white precipitate. The NAG-SSP-5S1D analyzer was used to measure turbidity at 0°–180° angle to detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles. The linear range of CPM measurements was between 0.008 and 11 m.mol/L, with correlation coefficient of 0.9983 and R2% = 99.65. The limit of detection was determined to be 0.0328 µg/sample from the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was less than 0.4% (n = 6

... Show More
View Publication
Scopus (1)
Scopus Crossref