We studied in this research how to find a method of estimating the quantity (Kinetically) of three kinds of Insecticide and their mixture, which are used in agriculture. The extracted insecticide from the polluted samples with these insect from air, soil, and the leaves of trees, have be used into the reaction with H2O2 and benzedine. The kinetic study of this reaction was formed in basic medium,( pH= 8.6), using UV. Spectra at (?= 420nm). The study showed that the reaction is the first order, and the speed of the reaction was used to estimate the concentration of insecticide in solution and mixture. The experiments of this study indicated that this method has the speed and efficiency for quantitatively estimating these insecticides in solution and mixture.
The main objective of this work was to adopt an environmentally friendly technology with enhanced results. The technology of magnetic water (MW) treatment system can be used in concrete mixture production instead of potable water (PW) to improve both workability and strength. Two types of concrete were adopted: normal concreter production with two grades 25 and 35 MPa and the self-compacted concrete (SCC) with 35 MPa grade. The concrete mixes containing MW instead of PW results showed that, for 25 MPa grade, an improvement in a compressive strength of 15.1, 14.8, and 10.2% was achieved for 7, 28, and 90 days, respectively. For 35 MPa grade, an improvement of 13.6, 11.5, and
The main objective of this work was to adopt an environmentally friendly technology with enhanced results. The technology of magnetic water (MW) treatment system can be used in concrete mixture production instead of potable water (PW) to improve both workability and strength. Two types of concrete were adopted: normal concreter production with two grades 25 and 35 MPa and the self-compacted concrete (SCC) with 35 MPa grade. The concrete mixes containing MW instead of PW results showed that, for 25 MPa grade, an improvement in a compressive strength of 15.1, 14.8, and 10.2% was achieved for 7, 28, and 90 days, respectively. For 35 MPa grade, an improvement of 13.6, 11.5, and
The drug promethazine hydrochloride (PRZH) forms with rhodium (II) a colored chelate (?max = 472 nm) complex at (pH = 2.1) which is extractable with benzyl alcohol as organic solvent. Under the appropriate experimental conditions a calibration plot was set up from which some analytical parameter were derived and deduced by regression. Standard addition procedure was also adopted. It has been estimated that the concentration of the drug PRZH to be 24.89 mg per unit and 24.19 mg per unit for both calibrations. Under optimal conditions, the developed method has been achieved the following characteristics: LDR (30 – 150 µg ml-1 ) PRZH , RSD % ( 0.6 – 2.47 ) , sandell sensitivity( 0.0844 µg. cm -2 ) , LOD ( 1.66 µgml-1 ) , recovery
... Show MoreIdentifying phenolic compounds in some genera belonging in the Amaranthaceae family by HPLC technique
The plant Zizyphus spina-christa grows wildly in the middle and southern of Iraq locally named Nabag. In this study the antibacterial activity of several different plant extract (alcoholic hot and cold extract 80%, aqueous hot and cold extract) was tested against some gram negative bacteria that related to Enterobacteriacea as follow; Pseudomonas aeruginosa, Escherchia coli Proteus mirabilis, Serratia mercesence,. Aeromonas sp, Klebsiella pneumoniae ,Shigella sp, Salmonella enteritidis (134), S. typhi(97), S. typhimurium (300) , S. typhi, . The results showed that efficient method of extract was alcoholic hot extract from other extract methods that are used in this study. The detection of active compound in crude extracts of the leaves show
... Show MoreThis study presents a rapid, sensitive, and straightforward approach to measure chlorpheniramine maleate (CPM) by using turbidity CFIA. The method involves CPM reacting with sodium nitroprusside (Nitropress) to produce a pale white precipitate. The NAG-SSP-5S1D analyzer was used to measure turbidity at 0°–180° angle to detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles. The linear range of CPM measurements was between 0.008 and 11 m.mol/L, with correlation coefficient of 0.9983 and R2% = 99.65. The limit of detection was determined to be 0.0328 µg/sample from the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was less than 0.4% (n = 6
... Show MoreBackground: Vitamin D deficiency/ insufficiency is common in different age groups in both genders especially among pregnant women and neonates where it is associated with several adverse outcomes including preeclampsia and preterm delivery. Objectives: To assess the extent of vitamin D deficiency/ insufficiency among mothers and their neonates and some factors related to it and identify some adverse outcomes of the deficiency/ insufficiency on neonates (preterm birth and low birth weight). Subject and Methods: A cross-sectional study was conducted on 88 Iraqi pregnant women and neonates admitted to “Al-Elwiya teaching hospital for maternity” in Baghdad- Al-Rusafah from 1st of June 2019 to 31st of August 2019. Dat
... Show MoreBackground: Vitamin D deficiency/ insufficiency is common in different age groups in both genders especially among pregnant women and neonates where it is associated with several adverse outcomes including preeclampsia and preterm delivery.
Objectives: To assess the extent of vitamin D deficiency/ insufficiency among mothers and their neonates and some factors related to it and identify some adverse outcomes of the deficiency/ insufficiency on neonates (preterm birth and low birth weight).
Subject and Methods: A cross-sectional study was conducted on 88 Iraqi pregnant women and neonates admitted to “Al-Elwiya teaching hospital for maternity” in Baghdad- Al
... Show MoreIn their cross-sectional study, Al-Rubaye et al studied the extent of vitamin D (VD) deficiency/ insufficiency, factors affecting its degree, and the adverse outcomes of the altered VD status among a group of mothers and their neonates from Baghdad, Iraq. They found that 96.6% of the mothers had VD deficiency/ insufficiency compared to 86.4% in their neonates. Maternal VD levels and neonatal weights were significantly correlated with neonatal VD levels. We believe that the study results need to be revised. This is based two points listed in this letter to editor