High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was tested by measuring average recovery values ranged between 94% - 101 %. For standerd solution, and 93%-99% of honey bee samples.
In this study the design and installation of evaporative air cooler was carried out using completely outdoor air (fresh air) according to two stage evaporative cooling principle. The laboratory equipment was installed by designing and manufacturing a cross flow plate heat exchanger, where aluminum plates used for this purpose with dimensions (50 × 30 × 40 cm). The surfaces of heat exchanger were covered by sawdust from wetted channels side, to increase the percentage of wetting these surfaces and hence improve the performance and efficiency of air cooler.
An experimental study was carried out to estimate the performance of cooling system, where som
... Show MoreAn experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.
Experiments were conducted to study axial liquid dispersion coefficient in slurry bubble column of 0.15 m inside diameter and 1.6 m height using perforated plate gas distributor of 54 holes of a size equal to 1 mm diameter and with a 0.24 free area of holes to the cross sectional area of the column. The three phase system consists of air, water and PVC used as the solid phase. The effect of solid loading (0, 30 and 60 kg/m3) and solid diameter (0.7, 1.5 and 3 mm) on the axial liquid dispersion coefficient at different axial location (25, 50 and 75 cm) and superficial gas velocity covered homogeneous-heterogeneous flow regime (1-10 cm/s) were studied in the present work. The results show that the axial liquid dispersion coeffic
... Show MoreBackground: Personality could be defined broadly as those characteristics of individuals that describe the pattern of feeling, cognition and behaving. Personality types can be measured by using one of personality type’s measures. Personality has been proposed to influence the oral health. The purpose of the present study was to assess the influence of Personality Types on caries experience in relation to salivary testosterone hormone among teachers in Baghdad city. Materials and Methods: Female teachers (n=534) of randomly selected schools were subjected to personality questionnaire using The Riso-Hudson Enneagram Type Indicator. Teachers were examined to estimate the caries experience according to the decayed-missing and filled i
... Show MoreA fully automatic electrothermal atomic emission spectrometry (ETA-AES) is described. This system is based on an echelle monochromator modified for wave¬length modulation which is completely controlled by microcomputer . The advantages of the system in atomic spectrometry have been discussed . Aspects of the analytical performances such as calibration ? dection limit, precision , and recovery for copper are considered . This system is applied for routine determination of copper in commercial powdered mill? by slurr>' atomization versus aqueous atomization techniques.
One of these plants utilized in traditional medicine is Lactuca seriolla Linn., which belongs to the Asteraceae family. It goes by a variety of common names in the world, including prickly lettuce, wild lettuce, jagged lettuce, and Kahu and khas. The work aimed to isolate and characterize some bioactive constituent(s) from the aerial part of Lactuca serriola utilizing Combiflash NEXTGEN and high-performance liquid chromatography (HPLC). Lactuca serriola (aerial part) was extracted with 80% ethanol, then fractionated with hexane. Then 250 mg of hexane extract was mixed with 4 g of silica gel and loaded in cartilage, then bounded to the gold column of combi flash using a solvent system comprised of ethyl acetat
... Show MoreObjective(s): To assess the types of violence among adolescents in Baghdad City.
A descripƟve study which was using the assessment approach was conducted on purposive sample of 60 parents of
adolescent for identify types of adolescents violence in their families, was selected according to specific criteria for
participating in health education program towards adolescents' violence control in Baghdad city.
Methodology: A questionnaire was constructed for the purpose of the study. It was consisted of two parts; the first
part which included the parents' demographic characteristics for parents (sex, age, educational level and socioeconomic
status); the second part included types of adolescent violence that reported by par
Abstract : A research was conducted to study the process parameters affecting hexavalent chromium Cr (VI) (carcinogenic compound) the removal percentage from the electrical industries company waste water that contain 88 mg/l of Cr (VI) concentration by adsorption onto tea wastes. Synthetic water with 88 mg/l Cr (VI) concentration was used. Several operation parameters affecting Cr (VI) removal efficiency were investigated, such as pH, initial Cr (VI) concentration, stirring time and tea wastes dose. The experimental results reveal that maximum Cr (VI) removal reached up to 94.26% at pH of 2, stirring time of 180 minute, tea wastes do
... Show More