This research studied the effect of magnetized water in concrete preparation and its effect on the presenting of cement in concrete mixtures also to find the ability of reducing the amount of cement in preparing one cubic meter, this is not exceed than 10% in one mixture , The experiments showed the preparation of standard cubes from the concrete which was used two kind of water magnetized water which was prepared by passing the tap water through the systems of different magnetic strength in terms of (6000,9000) Gauss and the ordinary water . The velocity of water through the magnetic field, which gives us the highest value for the compressive strength, was up to 1m/sec. to determine the best magnetic intensity, we examined The compressive strength and workability of the concrete which is not effect on the efficiency of the structure because of reducing cement percentage. The tests for compressive strength on concrete mixture with magnetized water appeared an increase (24%) compared to the results of the control cubes with fixed amount of cement; also the cubes with less amount of cement showed an increase (22%) and both cases give us higher compressive strength and workability.
Objective: Chronic periodontitis (CP) is a common inflammatory disease that causes destruction to the supporting tissues of the teeth. Many treatment modalities tried to stop the disease progression. Platelet-rich plasma (PRP) is one of the regenerative methods that used in adjunct to conventional periodontal treatment. The aim of this study was to evaluate the anti-inflammatory effect of PRP by monitoring the lymphocyte count before and after its application to the periodontal pocket. Materials and Methods: Twenty patients, with CP and a pocket depth equal to or deeper than 4 mm, subjected to scaling, root planing, and PRP injection into the pocket. The lymphocyte count measured before an
The process of employing modern technology in a consistent manner is what the researcher is interested in, and the psychological role of the sound effect in enhancing psychopathic representations in cinematic characters, which had a wide resonance in the field of cinematic films, and after the predominance of digital technology in the production of contemporary films, the sound effect has a higher efficiency And a good level of advanced aesthetic and dramatic expression in film employment, so many directors resorted to this type of films by using various new and advanced techniques and technological programs in their industry, since the traditional construction does not achieve the dazzling that the viewer desires.
Accordingly, th
... Show MoreThe research aims to know the influence of the intellectual capital on the internal control system in a sample of General Inspection Offices in Iraq. The research includes a sample of individuals who are working in these offices total sample (46) individuals distributed according to functional levels (General Inspector, Deputy Inspector General, and Director) , The data and information were collected by using questionnaire, which is done for this purpose, as well as personal interviews in order to reach to the results that achieve the aim of this research , Two hypotheses were formed , the first hypothesis consists of (4) secondary hypothesis , All these hypotheses were tested by using statistical tools such as (percentages, freq
... Show MoreThe research aims to identify the current (after the readings in the collection of foreign
students to the geographical material) To achieve this, the researcher developed the following
null hypothesis:
No statistically significant differences at the level of (0.05) between the average scores who
are studying the use of article readings and the average external degree students who are
studying material in the traditional manner of collection.
The researcher has chosen Qsidia middle school Amma, which includes six divisions for
Grade average, randomly selected Division (a) to represent the control group, while
representing the Division of (c) the experimental group and reached the research sample (44)
student, b
In this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.
In the current research, the work concentrated on studying the effect of curvature of solar parabolic trough solar collector on wind loading coefficients and dynamic response of solar collector. The response of collector to the aerodynamic loading was estimated numerically and experimentally. The curvature of most public parabolic trough solar collectors was investigated and compared. The dynamic response of solar collector due to wind loading was investigated by using numerical solution of fluid-structure interaction concept. The experimental work was done to verify the numerical results and shows good agreement with numerical results. The numerical results were obtained by using finite element software package (ANSYS 14). It was found
... Show More An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct