A particulate composite material was prepared by adding the Titanium dioxide (TiO2) with a particle size of (75-150) µm to Epoxy resin at weight percentage of (10%,20%,30%,40%,50%).The following some mechanical properties were studied,fracture toughness, hardness.casting preparation methods were used in this study includes preparing plate of matrix and composites. specimens were prepared according to ASTM for the Mechanical properties tests. After that Another samples were heat treated for three and six hour at 65C?. Fracture toughness (Kic) represent for stress intensity factor results were showed that the curve of three hours aging increases in fracture toughness (Kic) for composites but for six hours aging increases fracture toughness (Kic) for polymer matrix. Hardness tests was showed that hardness results increased with the increase in weight fraction while a samples that not treated thermally have higher hardness than the samples for treated thermally. Finally, fracture surfaces were showed morphology failure surfaces by using an optical Microscope.
YY Lazim, NAB Azizan, 2nd International Conference on Innovation and Entrepreneurship, 2014
The study aims to find out the extent to which several Iraqi institutional accreditation standards (governance and administration, scientific research, curricula) are applied in two public universities (Baghdad and Middle Technical University) and two private universities (Uruk and Al-Mansour College) by diagnosing strengths and weaknesses and proposing a mechanism and procedures to help educational institution aims to reduce or eliminate the gap. The study stems from the extent of application of several Iraqi institutional accreditation standards represented as it was worked on through observation and field coexistence to reach scientific and practical facts. The method of case study and comparison betwe
... Show MoreBackground: Rehabilitation of the carious tooth to establish tooth structure integrity required cavity design that show a benign stress distribution. The aim of this study was to investigate the influence of the cavity position on the stress values in the reamining tooth structure restored with amalgam or resin composite. Materials and methods: Seven 2-D models of maxillary first premolar include class I cavity design was prepared, one sound tooth (A) 3 composite (B1, B2, and B3) and 3 amalgam (C1, C2, and C3). In design (BI and C1) the cavity position is in the mid distance between bacc-lingual cusp tip, design (B2 and C2) and (B3 and C3) shifted toward the buccal cusp and the lingual cusp for 0.5 mm respectively. One hundred N vertical
... Show MoreAннотация
В статье представлены явления полисемии и омонимии в специализированной терминосистеме, а именно в геодезической терминологии; определены предпосылки и причины возникновения полисемии и омонимии в профессиональном языке в области геодезии и кадастра; установлены различия и взаимосвязь между понятиями омонимия и полисемия; выделены главных типы полисемантических тер
... Show Moreهدفت الدراسة إلى التعرف على مستوى تقييم الإعلاميين العراقيين المقيمين في الأردن لتغطية الإصلاحات السياسية و الاقتصادية في العراق من قبل الفضائيات العراقية. و هدفت كذلك إلى التعرف على الف
The purpose of this study is to investigate the histopathological response of dentinopulpal
response of human teeth to the Er: YAG laser cavity preparation in comparison with the conventional
class I cavity preparation. Thirty five sound human upper and lower first premolar teeth which were
needed to be extracted for orthodontic purposes were used in the study. Regarding to the method of
cavity preparation, the teeth were grouped into three groups; Group1; Control group which consists of
seven sound teeth without cavity preparation, Group2; Conventional cavity preparation group and group
3; Er: YAG laser cavity preparation group. Each of Group2 and3 consists of fourteen teeth that is
subdivided into: A. 7teeth that e
Background: The purpose of this study was to evaluate and compare centering ability and canal transportation of simulated S-shaped canals instrumented with four different types of rotary nickel-titanium systems. Materials and Methods: Forty simulated S-shaped canals in resin blocks were divided into four groups of ten each and were instrumented to an apical size 25 by different instrumentation technique using ProTaper Universal files (group A), ProTaperNext (group B), Reciproc (group C) and WaveOne (group D).Centering ability and canal transportation was measured at (11) measuring points from D0 to D10 bysuperimposion of the pre- and post-operative images obtained by using digital camera in standardized manner. An assessment of the canals
... Show More