A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations (tablets) and industrial wastewater samples. The proposed method was validated by sensitivity and precision which proves suitability for the routine analysis of tadalafil in true samples.
Among several separation processes, the air flotation distinguish as remarkably high potential separation process related to its high separation efficiency and throughput, energy-efficient, simple process, cost-effective, applicable to a wide range of oily wastewater and no by-products. The current study aimed to investigate the effect of the type and concentration of surfactant on the stability of oil-water emulsion and efficiency of the separation process. For this purpose, three types of surfactant where used (anionic SDS, mixed nonionic Span 85/Tween 80, and cationic CTAB). The results demonstrated that the Span 85/Tween 80 surfactant has the best stability, and it increases with the surfactant concentration augmentation. The removal ef
... Show MoreTetradentate bidentate Schiff base (L1) from 4-amino-1.5-dimethyl-2-phenyl-1.2-dihydropyrazol-3-one and 2-(1H-indol-3-yl)-ethylamine and benzene-1.4-dicarbaldehyde was synthesized and characterized as novel antioxidants. The Schiff base and its metal complexes Mn(II), Co(II),Cu(II), Zn(II), Cd(II) and Re(V) have been characterized by elemental microanalysis, metal content, chloride-containing, molar conductance, FT-IR, 1H-NMR, UVVis spectroscopy, magnetic susceptibility, mass spectra (MS), and thermal analysis (TGA). The structures of the prepared compounds were observed by antioxidant activities of the Schiff bases derivatives were investigated due to the imine group (-C=N-) and promising results were obtained. The results confirmed that c
... Show MoreThe aim of this paper is to identify Nano-particles that have been used in diagnosis and treatment of leishmaniasis in Iraq. All experiments conducted in this field were based on the following nanoparticles: gold nanoparticles, silver nanoparticles, zinc nanoparticles, and sodium chloride nanoparticles. Most of these experiments were reviewed in terms of differences in the concentrations of nanoparticles and the method that was used in the experiments whether it was in vivo or in vitro. These particles used in most experiments succeeded in inhibiting the growth of Leishmania parasites.
Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i
... Show MoreThis research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use
... Show MoreIn this study, copper was removed from an aqueous solution through electromembrane extraction (EME), a new approach that utilises a two-chamber electrochemical cell. It consists of two electrodes (stainless steel cathode and graphite anode) and a solid liquid membrane (SLM). SLM is composed of supporting polypropylene membrane impregnated with1-octanol as an organic solvent and bis(2-ethylhexyl) phosphate (DEHP) as a carrier. The effects of process parameters such as applied voltage, pH and copper concentration on the removal of copper were investigated. Response surface methodology (RSM) was applied to optimise these parameters and their interactions. Results indicated that pH has the major effect on the removal of copper, followed
... Show More
