A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) reagent was found to be 1:2. The recoveries were obtained in the range of 98.9 - 100.0% and a relative standard deviation of ±0.59 to ±2.73% depending on the concentration level of bismuth. The effect of interferences by a number of common cations and anions in the presence of composite mixture has been studied .The proposed method has been applied successfully for determination of bismuth in water samples and veterinary preparation .
Abstract: In this research, nanofibers have been prepared by using an electrospinning method. Three types of polymer (PVA, VC, PMMA) have been used with different concentration. The applied voltage and the gap length were changed. It was observed that VC is the best polymer than the other types of polymers.
In this research, nanofibers have been prepared by using an electrospinning method. Three types of polymer (PVA, VC, PMMA) have been used with different concentration. The applied voltage and the gap length were changed. It was observed that VC is the best polymer than the other types of polymers.
Background: Understanding the morphological characteristics between the floor of the maxillary sinus and the tips of the maxillary posterior roots is crucial in orthodontics involving diagnosis and treatment planning. The aim of this study was to evaluate the distances from the maxillary posterior root apices to the inferior wall of the maxillary sinus, thickness and density of maxillary sinus floor using cone-beam computed tomography images and the relationships between roots and maxillary sinus according to gonial angle and skeletal pattern. Materials and methods: Three-dimensional images of each root were checked, and the distances were measured along the true vertical axis from the apex of the root to the sinus floor, and the thickne
... Show MoreOne of the important units in Sharq Dijla Water Treatment Plant (WTP) first and second extensions are the alum solution preparation and dosing unit. The existing operation of this unit accomplished manually starting from unloading the powder alum in the preparation basin and ending by controlling the alum dosage addition through the dosing pumps to the flash mix chambers. Because of the modern trend of monitoring and control the automatic operation of WTPs due to the great benefits that could be gain from optimum equipment operation, reducing the operating costs and human errors. This study deals with how to transform the conventional operation to an automatic monitoring and controlling system depending on a Programmable
... Show MoreA new Schiff base (HL2) ligand (4‐{2‐[(2‐hydroxy‐benzylidene)‐amino]‐ethyl}‐benzene‐1,2‐diol) has been synthesized by condensing of 4‐(2‐amino‐ethyl)‐benzene‐1,2‐diol and 2‐hydroxy‐benzaldehyde. In turn, its transition metal complexes were prepared, having the following general formulas: Ni(L2)2, Pd(L2)2, and Pt(L2)22Cl. The prepared ligand and its metal complexes Ni(II), Pd(II), and Pt(IV) have been characterized by Fourier transform infrared (FTIR) spectra, proton nuclear magnetic resonance (1H‐NMR
The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.
... Show MorePure and doped barium titanate with Mg2+ ion at two molar ratios x= (5%, 10%) mol. has been synthesized by solid state reaction technique. The powders sintered at two temperatures (1000 °C and 1400 °C). An XRD technique was used in order to study the crystal structure of pure and doped barium titanate, which confirmed the formation of the tetragonal phase of BaTiO3, and then calculate the lattice parameters of pure and doped barium titanate, the addition of magnesium ion Mg2+ can lead to decreases lattice parameters.
Pure and doped barium titanate with Mg2+ ion at two molar ratios x= (5%, 10%) mol. has been synthesized by solid state reaction technique. The powders sintered at two temperatures (1000 °C and 1400 °C). An XRD technique was used in order to study the crystal structure of pure and doped barium titanate, which confirmed the formation of the tetragonal phase of BaTiO3, and then calculate the lattice parameters of pure and doped barium titanate, the addition of magnesium ion Mg2+ can lead to decreases lattice parameters.
ABSTRACT A simple, accurate, sensitive, and low-cost technique was advanced to measure the optical spectrum to the determination of lansoprazole in pure form and dosage forms. The method relies on the oxidation of the reagent 2,4-dinitrophenylhydrazine (2,4-DNPHz) with potassium periodate (KIO4) and coupling with the Lansoprazole (LPZ) in the alkaline medium to form a stable with reddish-brown colored dye with a maximum greatest absorption at 484.5 nm. The reaction is carefully completed when optimizing the variable affecting it. The concentration range from 1-30 μg/mL obegs Beer’s law and the molar absorptivity value of (13260.132) L/mol.cm. Detection limit was (0.1266 μg/mL) and Sandell’s sensitivity value ( 0.0278) μg/cm2. The met
... Show More