Mefenamic acid was esterified with starchwith[1:1] Molar ratio, as drug substituted with natural polymer, to prolongthe period of hydrolysis of drug polymer with other advantages. The new prodrug starch was characterized by FT-IR and UV-Visible and 1H-NMR spectroscopies. The physical properties were studied and controlled drug release was studied in different pH values at 37oC. The stability of drug was carried out by measuring the absorbance of mefenamic starch which hydrolyzed in HCl solution of pH 1.1 (artificial gastric fluid) and phosphate buffer of pH 7.4 (simulating intestinal fluid SIF) at 37oC for several days. The thermal analysis such as DSC was studied.
Two Schiff bases, namely, 3-(benzylidene amino) -2-thioxo-6-methyl 2,5-dihydropyrimidine-4(3H)-one (LS])and 3-(benzylidene amino)-6-methyl pyrimidine 4(3H, 5H)-dione(LA)as chelating ligands), were used to prepare some complexes of Cr(III), La(III), and Ce(III)] ions. Standard physico-chemical procedures including metal analysis M%, element microanalysis (C.H.N.S) , magnetic susceptibility, conductometric measurements, FT-IR and UV-visible Spectra were used to identify Metal (III) complexes and Schiff bases (LS) and (LA). According to findings, a [Cr(III) complex] showed six coordinated octahedral geometry, while [La(III), and Ce(III) complexes]were structured with coordination number seven. Schiff's bases a
... Show MoreÖz
Arzı Kanber/Kamber hikayesi Anadolu, Rumeli, Azerbaycan, Türkmenistan ve Irak gibi Türk dünyasının birçok yerinde birden fazla varyantı bulunan, çok sevilen ve yaygın olarak anlatılan aşk ve dramatik maceralı bir halk hikayesidir. Türk halk hikayelerinin en popüler olanlarından biri sayılan Arzı Kanber/Kamber hikayesi, Anadolu'nun birçok yöresinde bilinmesine rağmen Irak Türkmenleri arasında daha çok sevildiği ve yaygın olarak anlatıldığı tespit edilen birden fazla varyantından da görülebilir. Irak Türkmenleri arasında günümüze kadar hikayenin iki varyantı tespit edilmi
... Show MoreThe bilateral sagittal split osteotomy (BSSO) is the most popular orthognathic procedure performed by maxillofacial surgeons to treat skeletal class II and class III and to correct mandibular asymmetries. The study aimed to evaluate the lingual splitting patterns and lateral bone cut end (LBCE) in bilateral sagittal split osteotomy (BSSO) and their relation with the ramal thickness and the presence of impacted third molars using cone beam computed tomography (CBCT). This prospective observational study included patients with mandibular prognathism who were treated with BSSO with or without Le Fort I osteotomy. Cone beam computed tomography was used to measure the ramal thickness preoperatively and to evaluate the LBCE, and the lingu
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show MoreThe present study aimed to use the magnetic field and nanotechnology in the field of water purification, which slots offering high efficiency to the possibility of removing biological contaminants such as viruses and bacteria rather than the use of chemical and physical transactions such as chlorine and bromine, and ultraviolet light and boiling and sedimentation and distillation, ozone and others that have a direct negative impact on human safety and the environment. Where they were investigating the presence in water samples under study Coli phages using Single agar layer method and then treated samples positive for phages to three types of magnetic field fixed as follows (North Pole - South Pole - Bipolar) and compare the re
... Show MoreSome of metal compounds have been synthesized of record ligand from aldehid interaction of a substance which is salicyladehyde with another material which is urea. During the analysis of the metal component, The prepared complexes were characterized by elemental analysis, IR ,UV-visible , conductivity and magnetic susceptibility measurements. this confirms the ratio[1:1] between the metal and ligand. It is found that theortical values agree with practical values All the studied complexes are suggested as an octahedral stereochemistry.
RKRAS L. K. Abdul Karem, F. H. Ganim, Biochemical and Cellular Archives, 2018 - Cited by 2
This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra
... Show More