Preferred Language
Articles
/
bsj-2503
Extraction and Purification of albumin from Hunan plasma
...Show More Authors

This study includes adescription of Human serum Albumin by amodified using ion- exchange chromatography with manipulated comparison with cold ethanol precipitation method , It has been nticed that this procedure is superior orer the classical method . The Final yield by the new method 69.32% with purity of 83.42% compared with cohn which yield 60.30 % with purity of 80.7 % . The new method prored that it suitable for the pusi Fication of such material because it yield no precipitation material and it increases the Final yield of albumin solutions . • Human serum Albumin . • Albumin purification . • Ion – exchange chromatography . • Human plasma . • Albumin extraction .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Evaluation the levels of Plasma Interleukins (IL-8, IFN-?, IL-10) in Preeclamptic Pregnancies
...Show More Authors

This study is to evaluate plasma levels of several cytokines in preeclamptic pregnancies compared to those of healthy pregnancies. Ninety pregnant women with preeclampsia (37 mild & 53 severe) and thirty healthy pregnant women were enrolled in the study. Blood samples were taken and plasma levels of IL-8, IL-10, and IFN-? were measured by enzyme-linked immunosorbent assay (ELISA). Preeclamptic women and their severe cases but not mild cases had significantly (P<0.05) increased levels of plasma IL-8, and IFN-? as compared with healthy pregnancies. By contrast, plasma levels of IL-10 was significantly (P<0.05) increased in healthy pregnant women as compared to all groups of preeclampsia. Preeclampsia is associated with an imbalance betwe

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics
The Thermal Properties of Gliding arc Plasma Produced by Laboratory Reverse Vortex Flow System
...Show More Authors

A low-cost reverse flow plasma system powered by argon gas pumping was built using homemade materials in this paper. The length of the resulting arc change was directly proportional to the flow rate, while using the thermal camera to examine the thermal intensity distribution and demonstrating that it is concentrated in the centre, away from the walls at various flow rates, the resulting arc's spectra were also measured. The results show that as the gas flow rate increased, so did the ambient temperature. The results show that the medium containing the arc has a maximum temperature of 34.1 ˚C at a flow rate of 14 L/min and a minimum temperature of 22.6 ˚C at a flow rate of 6 L/min.

View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
The Effect of Grain Size-Secondary Electron Emission on Grain Growth in Dusty Plasma
...Show More Authors

The calculation of the charge on an isolated dust grain immersed in plasma with different grain sizes is a challenging one, especially under moderately high plasma temperature when secondary electron emission significant. The discrete charging model is used to calculate the charges of dust grain in dusty plasma. In this model, we included the effect of grain size dependence on secondary electron emission. The results show that the secondary electron emission from the glass dust grains due to energetic electron (40eV) can lead to the small grain to be slightly more positive than the large grain. Under these conditions, the smaller and larger grains would be attracted rather than repelled, which possibly lead to enhanced coagulation rates.

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic measurements of the electron temperature in low pressure microwave 2.45 GHz argon plasma
...Show More Authors

The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 30 2025
Journal Name
International Journal Of Environmental Analytical Chemistry
Comparative study of extraction and spectrophotometric determination of salbutamol sulphate by Fe3O4/SiO2/CPC and Fe3O4/Al2O3/CPC adsorbents: analytical greenness profile
...Show More Authors

ABSTRACT This study developed two adsorbents for extracting salbutamol sulphate (SAS) from water and urine samples after derivatisation with 2-aminobenzothiazole as a colour reagent. These adsorbents include cetylpyridinium chloride surfactant (CPC) modified silica and alumina-coated magnetite nanoparticles (Fe3O4/SiO2/CPC and Fe3O4/Al2O3/CPC). The derivatisation of SAS with the colour reagent resulted in an orange azo dye with maximum adsorption wavelengths of 443.0 nm. UV–Vis spectroscopy was used to identify the target analyte following the magnetic solid-phase extraction (MSPE) method. Under optimal conditions, the concentration ranges of 0.03–5.00 µg/mL and 0.05–6.00 µg/mL with good linearity (˃ 0.99), the detection limi

... Show More
Scopus
Publication Date
Thu Nov 21 2019
Journal Name
Al-kindy College Medical Journal
Urinary Tract Infection Risk Assessment By Non- Thermal Plasma In Iraqis Patients
...Show More Authors

Background: In the present study used device jet plasma needle with atmospheric pressure which  generates non thermal plasma jet to measure treatment potent with plasma against pathogenic bacteria  founded  in UTI  was inactivated with plasma at 10 sec,

Objective:. This work included the application of the plasma produced from the system in the field of bacterial sterilization , where sample of Gram- negative bacteria (Escherichia coli) were exposed to intervals (1-10)second . Midstream Urine samples swabs were obtained from patients with urinary tract infections.

Type of the study: Cross -sectional study.

Methods: The work were used i

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 30 2024
Journal Name
Iraqi Journal Of Science
Telescope Mirror Cleaning Using Atmospheric Pressure Multi-Channel Radio Frequency Plasma Jet
...Show More Authors

     In this work, the surface of the telescope’s mirror is cleaned using an atmospheric-pressure radio frequency plasma jet (APRFPJ), which is generated by Argon gas between two coaxial metal electrodes. The RF power supply is set to 2 MHz frequencies with three different power levels: 20, 50, and 80 W. Carbon, that has adhered to the surface, can be effectively removed using the plasma cleaning technique, which also modifies any residual bonds. The cleaned surface was clearly distinguished using an optical emission spectroscopy (OES) technique and a water contact angle (WCA) analyzer for the activation property on their surfaces. The sample showed a super hydrophilic surface at an angle of 1° after 2.5 minutes of plasma tre

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Annals Of Medicine And Surgery
Plasma d-dimer level correlated with advanced breast carcinoma in female patients
...Show More Authors

View Publication
Scopus (12)
Crossref (13)
Scopus Crossref
Publication Date
Sun Dec 02 2018
Journal Name
Iraqi Journal Of Physics
Optical properties for TiO2 / PMMA nanocomposite thin films prepared by plasma jet
...Show More Authors

PMMA/TiO2 homogeneous thin films were deposited by using plasma jet system under normal atmospheric pressure and room temperature. PMMA/TiO2 nanocomposite thin film synthesized by plasma polymerization. Titanium oxide was mixed with Methyl Methacrylate Monomer (MMA) with specific weight ratios (1, 3 and 5 grams of TiO2 per 100 ml of MMA). Optical properties of PMMA/TiO2 nanocomposite thin films were characterized by UV-Visible absorption spectra using a double beam UV-Vis-NIR Spectrophotometer. The thin films surface morphological analysis is carried out by employing SEM. The structure analysis are achieved by X-ray diffraction. UV-Visible absorption spectra shows that the increasing the concentration of titanium oxide added to the polym

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Aug 05 2022
Journal Name
Spectroscopy Europe
Raman spectroscopy analysis for monitoring of chemical composition of aspirin after exposure to plasma flame
...Show More Authors

A Raman spectroscopy method was optimised to examine the chemical changes of aspirin tablets after interaction with helium temperatures. Several aspirin tablets were exposed to plasma-assisted desorption ionisation flame for different times (10, 30, 50, 60, 180 and 300s) and then analysed by Raman spectroscopy using optimal conditions. The changes in chemistry between exposed and fresh (without exposure to plasma) tablets were compared. The vibrational peaks of the aspirin molecule in the Raman spectrum were identified by checking the peak position. The results showed clear spectra with increases in intensity of vibrational peaks until 30s, whereas no spectra were measured for the exposed tablets to plasma flame after 50s. It can, the

... Show More
Preview PDF
Scopus (11)
Scopus