Commercially pure titanium (cpTi) is widely used as dental implant material although it was found that titanium exhibited high modulus of elasticity and the lower corrosion tendency in oral environment. Niobium(Nb) was chosen for this study as an alternative to cpTi implant material due to its bioinert behavior and good elastic modulus and moderate cost in addition to corrosion resistance. This study was done to evaluate the effect of biomimetic coating on the surface properties of the commercially pure titanium and niobium implants by in vitro and in vivo experiments. The in vitro study was involved etching the samples of each material in HCl then soaking in 10M NaOH aqueous solution. These samples were then immersed in a 5 times concentrated simulated body fluid for 14 days. Scanning Electron Microscope, Energy Dispersive X-ray, and X-Ray Diffraction tests were done to analyze surface changes. The in vivo study was done by the implantation of screw-shaped implants (two from each material, uncoated and the other was biomimetically coated) in the tibias of New Zealand rabbits. After 2 and 4 weeks of healing period, 20 rabbits were sacrificed for each period. A removal torque was done for ten animals in each group, whereas the other ten were used for histological testing and histomorphometric analysis with optical microscope.The in vitro experiments showed that the use of 14 days immersion in a concentrated simulated body fluid produced a layer of calcium phosphate on metal surfaces. The removal torque values and new bone formation were increased significantly in Nb than Ti, in coated than uncoated screws, and in 4 weeks than 2 weeks healing periods. The Nb implants had better biomechanical and biological properties than the commercially pure titanium implants and can be used as an alternative dental implant.
Fast-dissolving films are one of the interested delivery systems for oral solid dosage forms to overcome swallowing difficulty for geriatric and pediatric patients. Zafirlukast (ZLK) is one of the most commonly used oral medication for treatment of asthmatic patients particularly mild to moderate cases. Oral fast dissolving films of ZLK were prepared using two different filming forming polymers, hydroxypropyl methylcellulose (HPMC) and sodium carboxymethyl cellulose (SCMC). Different concentrations of the 2 polymers were used to prepare 10 formulas. Other excipients were also added at various ratios to produce 10 different formulations. These were maltodextrin, crosspivodone, polyvinylpyrrolidone (PVP), and banana powder. In vitro c
... Show MoreThis paper present a study about effect of the random phase and expansion of the scale sampling factors to improve the monochrome image hologram and compared it with previous produced others. Matlab software is used to synthesize and reconstruction hologram.
Biological activity substances was investigated in watery extract of lentil which found to contain phenols, tannin, saponins and resins while, flavons, terpens and steroids were not exist in the extract details explained that 5%, 10% of lentil extract largly inhibited the growth of Psedumonas aeruginosa then Escherichia coli and Bacillus subtilis. The growth of both Staphylococcus aureus and Salmonella typhimurium were slightly affected by all extract concentration. Extracellular protease were screened in all bacterial species under study. Complete inhibition was achieved for extracellular protease while different percentage of protease inhibition were seen for intracellular proteases.
Purpose: To evaluate the effect of different surface treatments on shear bond strength between dentin and IPS e.max lithium disilicate glass-ceramic. Materials and Methods: Eighteen extracted third molars were embeded in epoxy resin. The tooth was sectioned vertically in mesiodistal direction using a low speed hard tissue microtome. The buccal and lingual surfaces of each section were ground flat using 600 grit Silicone carbide paper. Eighteen ceramic discs consisted of lithium disilicate glass-ceramic were prepared with a diameter of 4.7mm and height of 2.2mm. The discs were divided in two groups (n=10): (1) IPS e.max treated with hydrofluoric acid and Monobond Plus (MBP) and (2) IPS e.max treated with Monobond Etch &Prime (MBEP). The toot
... Show MoreThe aim: Infection with the hepatitis B virus (HBV) caused by blood transfusion is a big problem throughout the world. The aim of study is to determine the faster and more accurate methods for detection of hepatitis B infections by serological screening and PCR- amplification. Materials and methods: A total of 140528 donors were tested for HBsAg and total anti-HBc from January to October 2021 in Iraq’s National Blood Transfusion Center; however, only 100 samples with HBsAg (-) and anti-HBc (+) were collected and tested for HBV DNA using quantitative real-time PCR. Results: From 2015 to 2021, the percentage of HBsAg positive donors was 0.33 percent in 2015, 0.32 percent in 2016, 0.30 percent in 2017, 0.28 percent in 2018, 0.23 pe
... Show MoreAbstract:
The aim of the research is to demonstrate the impact of the salary localization service in enhancing banking competitive advantage. In order to achieve this goal, salary localization was chosen as an independent variable and its impact was studied on the dependent variable, which is the competitive advantage. The research problem lies in the fluctuation of the salary localization service from one bank to another and the impact of this on the competitive advantage. The study sample included five private Iraqi banks, namely (the National Bank of Iraq, the International Development Bank, Assyria International Bank, Al Khaleej Commercial Ban
... Show MoreHumanoids or bipedal robots are other kinds of robots that have legs. The balance of humanoids is the general problem in these types when the other in the support phase and the leg in the swing phase. In this work, the walking pattern generation is studied by MATLAB for two types of degrees of freedom, 10 and 17 degrees of freedom. Besides, the KHR-2HV simulation model is used to simulate the experimental results by Webots. Similarly, Arduino and LOBOT LSC microcontrollers are used to program the bipedal robot. After the several methods for programming the bipedal robot by Arduino microcontroller, LOBOT LSC-32 driver model is the better than PCA 96685 Driver-16 channel servo driver for programming the bipedal walking rob
... Show More