A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present method has been developed for the determination of sulphite in the presence of thiosulphate. Good recoveries of sulphite from various water samples are achieved using the proposed method.
The aim of this research is to determine the uranium concentration and its distribution in many sheep organs that live in different region of Iraq. The uranium concentration in tissue samples is measured by using fission tracks registration in CR-39 detector that caused by the bombardment of U235 with thermal neutrons from (241Am-Be) neutron source of thermal flux (5x 103 n.cm-2. s-1). The results show that the maximum uranium concentration in bronchiole tissues of the animals was found in Karbala city (3.706ppm) while the minimum concentration (0.127 ppm) was found in Al-Faluja city, also the same result in lung tissue the maximum value was found in Karbala city (2.313ppm) and the minimum concentration in Al Fluja (0.082). Otherwise,
... Show MoreThis work reports the development of an analytical method for the simultaneous analysis of three fluoroquinolones; ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL) in soil matrix. The proposed method was performed by using microwave-assisted extraction (MAE), solid-phase extraction (SPE) for samples purification, and finally the pre-concentrated samples were analyzed by HPLC detector. In this study, various organic solvents were tested to extract the test compounds, and the extraction performance was evaluated by testing various parameters including extraction solvent, solvent volume, extraction time, temperature and number of the extraction cycles. The current method showed a good linearity over the concentration ranging from
... Show MoreThe study's primary purpose is to explore an appropriate way of monitoring and assessing water depths using the satellite remote sensing technique of the Al Habbaniyah Lake in Iraq. This research studied the experience-conditions (thresholds) of different bands for multi-temporal satellite image data with different satellite image sensors (Landsat 5-TM, and EO1-ALI) for the same region, to recognize regions of water depths. The threshold values are taken that to separate the Al Habbaniyah Lake to the required depths (shallow, deep, and very deep), as a supervised method. A three-dimension feature space plot had used to represent these regions. The relationship of the mean values of the three separated water regions with all TM and A
... Show Moreالصيغة العامة للمعقدات الجديدة [M2(BDS)Cl4] الناتجة من تفاعل الليكاند الجديد] ن1,ن4-ثنائي(1أ –بنزو]د[ اميدازول-2-يل)-ن1,ن4-ثنائي(4-ثنائي مثيل امينو) بنزيل) سكسنمايد[ (BDS) مع الايونات الفلزية الكادميوم, الكوبلت, الزئبق, النحاس والنيكل. تم اشتقاق هذا الليكاند من تفاعل المواد الثلاث 4-(ثنائي ميثيل أمينو) بنزالدهيد، 2-أمينو بنزيميدازول، وكلوريد السكسينيل. تم تشخيص المركبات باستخدام مطيافية طيف الاشعة تحت الحمراء وطيف الرن
... Show MoreThis paper concerns is the preparation and characterization of a bidentate ligand [4-(5,5- dimethyl-3-oxocyclohex-1-enylamino)-N-(5-methylisoxazol-3-yl) benzene sulfonamide]. The ligand was prepared from fusing of sulfamethoxazole and dimedone at (140) ºC for half hour. The complex was prepared by refluxing the ligand with a bivalent cobalt ion using ethanol as a solvent. The prepared ligand and complex were identified using Spectroscopic methods. The proposed tetrahedral geometry around the metal ions studied were concluded from these measurements. Both molar ratio and continuous variation method were studied to determine metal to ligand ratio (M:L). The M to L ratio was found to be (1:1). The adsorption of cobalt complex was carried out
... Show MoreENGLISH