Preferred Language
Articles
/
bsj-2444
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the argon gas temperature, where argon gas temperature the exceed 350 ? as maximum value and study the effect of gas flow rate on the optical properties

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 01 1997
Journal Name
Polymer-plastics Technology And Engineering
An Efficient Method for Real Gas Pseudopressure Calculation
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
Gas Adsorption and Storage at Metal-Organic Frameworks
...Show More Authors

Dry gas is considered one of the most environmentally friendly sources of energy. As a result, developing an efficient strategy for storing this gas has become essential. In this work, MOF-199 was synthesized and characterized in order to investigate the MOF-199 in dry gas adsorption using a built-in volumetric system (methane, ethane, and propane from Basrah gas company). The MOF-199 (metal organic framework) was synthesized using the solvothermal method at 373K for 24h, and then it was characterized. The dry gas adsorption on MOF-199 was studied under various conditions (adsorbent dosage, contact time, temperature, and pressure). The isothermal adsorption of the dry gas had been studied on MOF-199 using two types of mo

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Chalcogenide Letters
Copper telluride thin films for gas sensing applications
...Show More Authors

Copper Telluride Thin films of thickness 700nm and 900nm, prepared thin films using thermal evaporation on cleaned Si substrates kept at 300K under the vacuum about (4x10-5 ) mbar. The XRD analysis and (AFM) measurements use to study structure properties. The sensitivity (S) of the fabricated sensors to NO2 and H2 was measured at room temperature. The experimental relationship between S and thickness of the sensitive film was investigated, and higher S values were recorded for thicker sensors. Results showed that the best sensitivity was attributed to the Cu2Te film of 900 nm thickness at the H2 gas.

View Publication
Crossref (5)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Open Access Journal Of Chemistry
Gas Storage and Separation in Metal Organic Frameworks
...Show More Authors

View Publication
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Open Access Journal Of Chemistry
Gas Storage and Separation in Metal Organic Frameworks
...Show More Authors

Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Chalcogenide Letters
Copper telluride thin films for gas sensing applications
...Show More Authors

Scopus (5)
Scopus
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Bubble Size Distribution In Gas-Liquid Dispersion Column
...Show More Authors

The present work investigates the effect of; superficial air velocities of: 1, 3, and 6 cm/s for two types of perforated distributor on hydrodynamic characteristic in a gas-liquid dispersion column of; air-water, and airaqueous-n-propanol solution. Bubble distribution, gas holdup, and power consumption are parameters take in consideration. Experimental work was carried out in perspex column of 8.5 cm inside diameter and 1.5 m height. Two types of bubble generator (perforated plate) were fixed at the bottom of the column; plate A (99 holes of 0.5 mm diameter and free area of 0.34%), plate B (20 holes of 1.5 mm diameter and free area of 0.62%). Photographic technique was used to measure the bubble parameters. The experimental results were

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
A Study of Fluctuation and Expansion Ratios for Gas-Solid Fluidized Columns
...Show More Authors

The fluctuation and expansion ratios have been studied for cylindrical gas-solid fluidized columns by using air as fluidizing medium and Paracetamol as the bed material. The variables were the column diameter (0.0762, 0.15, and 0.18 m), static bed height (0.05, 0.07, and 0.09 m), and air velocity to several times of minimum fluidization velocity. The results showed that both the fluctuation and expansion ratios had a direct relation with air velocity and an inverse one with column diameter and static bed height. A good agreement was between the experimental results and the calculated values by using the correlation equations from the literature.

View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
مجلة المستنصرية للعلوم والتربية
Calculation of Electron Drift Velocity in Xenon Gas Using Boltzmann Equation Analysis
...Show More Authors

Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
The Preparing and Characterization of Nanocomposite (PTh/SWCNT) for NO2 Gas Sensing
...Show More Authors

We prepared polythiophene (PTH) with single wall carbon nanotube (SWCNT) nanocomposite thin films for Nitrogen dioxide (NO2) gas sensing applications. Thin films were synthesized via electrochemical polymerization method onto (Indium tin oxide) ITO coated glass substrate of thiophene monomer with magnesium perchlorate and different concentration from SWCNT (0.012 and 0.016) % in the presence130mL of Acetonitrile used. X-ray diffraction (XRD), Field Emission Scanning Electron microscopy (FE-SEM), Atomic Force Microscope (AFM) and Fourier Transform Infrared Spectroscopy (FT-IR) were used to characterized these nanocomposite thin films. The response of these nanocomposite for NO2 gas was evaluated via monitoring the change

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Crossref