The effect of ozone gas with temperatures 35. 40 and 45 Celsius to control on larval and adult stages of Tribolium castaneum was tested and at time of exposure 1.0, 3.0, 7.0, 9.0, 11.0, 13.0 hours and the level of relative humidity prevailing during the test 45 ± 1%. Results showed significant differences between the exposure times, when the percentage of mortality 100% between larvae (primary, intermediate and advanced) in the treatment effect at a temperature of 35 Celsius with ozone gas at exposure time to 9.0, 11.0, 11.0 hours for the three ages respectively, and adult (male and female) in the same treatment when the three heat degrees had given ratios the total mortality reached 100% of both males at exposure time to 7.0 ,3.0, 1.0 hour respectively and females at exposure time 9.0 ,7.0 ,1.0 hour respectively, While completely failed under the effect of a heat treatment at temperatures of 35 Celsius for both stages respectively, while the effect was clear when the temperature is 45 Celsius where the of total mortality of 100% when the heat treatment of the stage of the larval and adult at the time 7.0, 3.1, 1.0 hour respectively. This means that the combined effect of ozone gas with temperatures has resulted in the reduction of the time needed to get the total mortality in both insect stages and significantly influential and that mortality rates in the two stages were increasingly higher degree of exposure used heat and high heat was the lead in reducing the time of exposure and even access to the total mortality.
Internal control system is a safety valve that preserves economic units assets and ensure the accuracy of financial data, as well as to obligation in the laws, regulations, administrative policies ,and improve the efficiency, effectiveness and economic of operation, so it has become imperative for these units attention to internal and developed control system The research problem in exposure the economic units when the exercise of their business to many of the risks to growth or hinder the achievement of its objectives and the risks (financial, operational, strategy, risk) and not it rely on risk Assessment according to modern scientific methods, as in Brown's risk Classification, Which led to the weakness of the internal control identif
... Show MoreThe aim of the research is to use the data content analysis technique (DEA) in evaluating the efficiency of the performance of the eight branches of the General Tax Authority, located in Baghdad, represented by Karrada, Karkh parties, Karkh Center, Dora, Bayaa, Kadhimiya, New Baghdad, Rusafa according to the determination of the inputs represented by the number of non-accountable taxpayers and according to the categories professions and commercial business, deduction, transfer of property ownership, real estate and tenders, In addition to determining the outputs according to the checklist that contains nine dimensions to assess the efficiency of the performance of the investigated branches by investing their available resources T
... Show MoreIn this paper, the species of the genus of Chlaenius Bonelli, 1810 (Coleoptera, Carabidae) were reviewed, and it was revealed that there are 21 confirmed species in Iraq; among them, the species of Chlaenius hamifer Chaudoir, 1856 was recorded for the first time in Iraq.
Diagnostic characters, a redescription of some of the morphological features, photographs and illustrations are provided for the new record species in this investigation.
The evaluation and efficiency and effectiveness of account system for the department of delegation and cultural Relationships in the center of ministry of higher Education and Scientific research Considered as a very important and active subjects in the modification of accounting system in this department and to develop it and make it able to make available important and accurate information for the planning requirements and monetary and evaluation performance and to make decisions, besides to develop the performance of Iraqi Cultural departments working abroad and to render its role effective to serve the students of higher education in the progressive Countries to facility its growing in scientific and professional and technica
... Show MoreEleven hymenopterous species: two braconids, seven eulophids and two pteromalids
parasitized the larvae of Phytomyza horticola Goureau. The activity of the parasites began at
the end of April and evidently increased during May. The female of the parasites fed and
parasitized mostly on the second and third larval instars of P. horticola . Diglyphus iseae
Walker and Cirrospilus vittatus Walker were dominant larval parasites. Chrysocharis
pentheus Walker and Pediobius acantha Walker were main pupal parasites.
Zinc oxide (ZnO) nanostructures were synthesized through the hydrothermal method at various conditions growth times (6,7 and 8 hrs.) and a growth temperature (70, 90, and 100 ºC). The prepared ZnO nanostructure samples were described using scanning electron microscopy (SEM) and X-ray diffractometer to distinguish their surface morphologies and crystal structures. The ZnO samples were confirmed to have the same crystal type, with different densities and dimensions (diameter and length). The obtained ZnO nanostructures were used to manufacture gas sensors for NO2 gas detection. Sensing characteristics for the fabricated sensor to NO2 gas were examined at different operating temperatures (180, 200, 220, and 240) ºC with a low gas concentrati
... Show MoreEntropy generation was studied for new type of heat exchanger (shell and double concentric tubes heat exchanger). Parameters of hot oil flow rate, temperature of inlet hot oil and pressure drop were investigated with the concept of entropy generation. The results showed that the value of entropy generation increased with increasing the flow rate of hot oil and when cold water flow rate was doubled from 20 to 40 l/min, these values were larger. On the other hand, entropy generation increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, at a certain hot oil inlet temperature, the entropy generation increased with the pressure drop at different hot oil inlet flow rates. Final
... Show More