Plasma physics and digital image processing technique (DIPT) were utilized in this research to show the effect of the cold plasma (plasma needle) on blood cells. The second order statistical features were used to study this effect. Different samples were used to reach the aim of this paper; the patients have leukemia and their leukocytes number was abnormal. By studying the results of statistical features (mean, variance, energy and entropy), it is concluded that the blood cells of the sample showed a good response to the cold plasma.
The recurrent somatic variations in
The aim of the study was to detect the frequency of R132 mutations in the
The systemic and resistant nature of metastatic castration-resistant prostate cancers (mCRPC) renders it largely incurable even after intensive multimodal therapy. Proliferation, survival, and epithelial-mesenchymal transition (EMT) are three fundamental events that are deeply linked to carcinogenesis. Hence, it is necessary to find a new combination of several therapies, targeting those vital mechanisms without causing side effects. Significant research works have shown differential low expression of the metabolic Farnesoid X receptor (FXR) in primary and metastatic prostate cancer suggesting their importance in prostate pathogenesis. Obticholic acid (INT 747), a potent FXR agonist is widely used in primary biliary chola
... Show MoreBackground: Although the issue of anemia after renal transplantation (RT) has received increasing attention lately, the data on the exact prevalence of post-transplantation anemia (PTA) in the Iraqi patients are limited. Objective: In this study we sought to determine the prevalence of PTA among Iraqi patients and to correlate the renal allograft function measurements and the use of immunosuppressant with the prevalence of anemia. Patients and Methods: One hundred and twelve (74 male, 38 female) kidney transplant recipients (KTR) attending the kidney transplant center at surgical specialties hospital were studied. All patients were on maintenance, combined immunosuppressive therapy. The renal function tests [blood urea, serum cre
... Show MoreMagnesium hydroxide was used as flame inhibitor to increased flame resistance for tires .Magnesium hydroxide was adding with (5%,10%) weight percents to rubber master batch of tire and then exposed the resulting material to a flame generated from gas torch with (10 mm) exposure distance . Method of measuring the surface temperature opposite to the flame was used to determine the heat transferred through tire material. The results were obtained shows enhanced flame resistance for tire by added magnesium hydroxide and this resistance increased by increasing hydroxide Percentage .
The aim of the research is to identify to what extent to which Malcolm Baldrige standards of total quality are applied in the after-sales services of a private sector company for electrical appliances, from the point of view of administrative leaders, in it. To achieve this aim a questionnaire has been used to measure the degree of application of Malcolm’s seven criteria for total quality, namely: (leadership, strategic planning, focus on the customer, measurement and analysis and knowledge management, focus in human resource and operation management and results of the company’s management), the research found that the company achieved a good level of the standard from the de
... Show MoreConcerns about the environment, the cost of energy, and safety mean that low-energy cold-mix asphalt materials are very interesting as a potential replacement for present-day hot mix asphalt. The main disadvantage of cold bituminous emulsion mixtures is their poor early life strength, meaning they require a long time to achieve mature strength. This research work aims to study the protentional utilization of waste and by-product materials as a filler in cold emulsion mixtures with mechanical properties comparable to those of traditional hot mix asphalt. Accordingly, cold mix asphalt was prepared to utilize paper sludge ash (PSA) and cement kiln dust (CKD) as a substitution for conventional mineral filler with percentages ranging fro
... Show MoreIn the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the
... Show MoreIn this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in
... Show MoreThe influence of the grounded electrode area on the ignition voltage in capcitively coupled radio frequency discharge at 13.56 MHz in argon gas is studied experimentally. The results indicate a systematic decrease of the breakdown voltage with increasing grounded electrode area for the same pd value. Results show that the secondary ionization coefficient γ increases with the increase of grounded electrode area. Furthermore, results also the discharge current at the breakdown voltage increases almost linearly with the increase of electrode area suggesting an almost constant current density.