Zinc oxide nanoparticles sample is prepared by the precipitation method. This method involves using zinc nitrate and urea in aqueous solution, then (AgNO3) Solution with different concentrations is added. The obtained precipitated compound is structurally characterized by X-ray diffraction (XRD), Scanning electron microscopy (SEM), Atomic force microscopy (AFM) and Fourier transform infrared spectroscopy (FTIR). The average particle size of nanoparticles is around 28nm in pure, the average particle size reaches 26nm with adding AgNO3 (0.05g in100ml =0.002 M) (0.1g in100ml=0.0058M), AgNO3 (0.2g in 100ml=0.01M) was 25nm. The FTIR result shows the existence of -CO, -CO2, -OH, and -NO2- groups in sample and oxides (ZnO, Ag2O).and used an atomic force microscope and microscope scanning electron to model the record.
In this research paper, two techniques were used to treat the drill cuttings resulting from the oil-based drilling fluid. The drill cuttings were taken from the southern Rumaila fields which prepared for testing and fixed with 100 gm per sample and contaminated with two types of crude oil, one from Rumaila oilfields with Sp.gr of 0.882 and the other from the eastern Baghdad oilfield with Sp.gr of 0.924 besides contamination levels of 10% and 15% w/w in mass. Samples were treated first with microwave with a power applied of 540 & 180 watts as well as a time of 50 minutes. It was found that the results reached below 1% w/w in mass, except for two samples they reached below 1.5% w/w in mass. Then, the sample of 1.41% w/w in mass,
... Show MoreIn this research, the semiparametric Bayesian method is compared with the classical method to estimate reliability function of three systems : k-out of-n system, series system, and parallel system. Each system consists of three components, the first one represents the composite parametric in which failure times distributed as exponential, whereas the second and the third components are nonparametric ones in which reliability estimations depend on Kernel method using two methods to estimate bandwidth parameter h method and Kaplan-Meier method. To indicate a better method for system reliability function estimation, it has be
... Show MoreBackground: One of the more significant hormonal systems, the renin-angiotensin-aldosterone system, controls the kidney function, adrenal gland through its effect on the balance of sodium and potassium, blood pressure, fluid volume, and also manages the functions of cardiovascular. Objective: To clarify the interrelationship between renal dysfunction and renin-angiotensin-aldosterone system. Patients and Methods: One hundred samples were collected from December 1, 2022, to February 18, 2023, from Al Shams Medical Laboratories (56 male, and 44) female, age range (of 45-60 years), all of them were volunteers suffering from chronic renal failure in the third stage the average glomerular filtration rate was 35. 70 ± 0.37 12
... Show MoreBackground : Xanthomatosis is a disease in which large tendon tumors can occur, especially in the Achilles tendon. This disease is a rare interesting orthopaedic condition.
Case Report:A case of a twenty eight year old girl patient with giant bilateral Achilles tendon xanthomas in which both tumors were resected.
There was no ulceration on the both sides. The patient was treated by total resection of the lesion and reconstruction using tendon transfer of the Peroneus brevis and Flexor hallusis longus. Postoperative treatment consisted of six weeks lower leg cast immobilization followed by partial weight bearing. After 4 months the patient was able to walk pain free without any difficultie
... Show MoreThe study using Nonparametric methods for roubust to estimate a location and scatter it is depending minimum covariance determinant of multivariate regression model , due to the presence of outliear values and increase the sample size and presence of more than after the model regression multivariate therefore be difficult to find a median location .
It has been the use of genetic algorithm Fast – MCD – Nested Extension and compared with neural Network Back Propagation of multilayer in terms of accuracy of the results and speed in finding median location ,while the best sample to be determined by relying on less distance (Mahalanobis distance)has the stu
... Show MoreThe study aimed to identify Human Papillomavirus (HPV) and its genotypes prevalent among Iraqi women. They collected 89 cervical swab samples from diagnosed patients at Baghdad Teaching Hospital's Early Detection Clinic. Using PCR technique on 19 samples, they found HPV16 (57.89%) and HPV6 (10.52%) genotypes, while HPV-11, 18, and 45 were absent. HPV 16 and HPV 6 were common in cervical cancer among Iraqi women. Sequencing revealed nucleic acid variants in HPV-6 (124A>C) and HPV-16 (225G>T) E6 genes, resulting in silent effects on the encoded protein. These changes didn't alter amino acid residues (p.74I= and p.L117=). Phylogenetic analysis showed substantial distances between their samples and other viral types, indicating di
... Show More