In the present study, new five polymers of acryloyl chloride have been synthesized by reaction 4-aminoantipyrine with many substituted acid chloride (A-E). Then condensation of polyacryloyl chloride with the product in one step (A-E), in a suitable solvent in the presence amount of (Et3N) to obtain new polyimides(A1-E5). The prepared compounds were characterized by UV. FT-IR, 1H-NMR and 13C-NMR spectroscopy and measuring of other physical properties such as softening point, melting point and solublities.
The conservation for biodiversity in Iraqi freshwater environments is important to protecting native species from the environmental impacts of alien species. Clarias gariepinus (Burchell, 1822) (Siluriformes, Clariidae) has been recognized as an alien species in Iraqi water bodies. This study aims to use molecular DNA to identify this catfish and trace its origins using. The DNA sequences of C. gariepinus were done using the mitochondrial DNA cytochrome c oxidase subunit 1 (COI) gene, and a specific primer set. The polymerase chain reaction (PCR) amplification was used to align the COI gene as a barcoding marker. After analysis, the sequences were compared with sequences in the National Center for Biology Information (NCBI) database
... Show MoreContracaecum rudolphii Hartwich, 1964 is a nematode which causes major concerns to human and wildlife animal’s health. However, the population genetics of C. rudolphii has been poorly studied in Iraq. In order to gain a deeper understanding in the outline of the genetic diversity of the nematode C. rudolphii that were isolated from its host cormorant Phalacrocorax carbo (Linnaeus, 1758), in the middle areas of Iraq, twenty specimens of C. rudolphii adults were isolated from nine individuals of P. carbo. The first (ITS-1) internal transcribed spacers (ITS) of ribosomal DNA (rDNA) of C. rudolphii were amplified using conventional polymerase chain reaction (PCR); then, the amplicons were subjected to sequencing. Concatenation of ITS-1 (rD
... Show MoreIn petroleum reservoir engineering, history matching refers to the calibration process in which a reservoir simulation model is validated through matching simulation outputs with the measurement of observed data. A traditional history matching technique is performed manually by engineering in which the most uncertain observed parameters are changed until a satisfactory match is obtained between the generated model and historical information. This study focuses on step by step and trial and error history matching of the Mishrif reservoir to constrain the appropriate simulated model. Up to 1 January 2021, Buzurgan Oilfield, which has eighty-five producers and sixteen injectors and has been under production for 45 years when it started
... Show MoreAeromonas salmonicida is a fish pathogen and recognized to cause a variety of diseases in humans. There are a few information about A.salmonicida in Iraq and there is no any previous molecular study on it. During the period of December 2017 to May 2018; Sixteen isolates of the A. salmonicida were isolated and identified from 300 common carp (Cyprinus carpio) fishes stomach in aquarium of Erbil city/ Iraq by using manual, automated Vitek 2 compact system, and confirmed by PCR using gene TonB-dependent siderophore (364bp). Antimicrobial susceptibility was determined by disk diffusion method and the results found that all isolates 100% susceptible to imipenem, 100% resistant to nalidixic acid and variable resistan
... Show MoreIt is well known that petroleum refineries are considered the largest generator of oily sludge which may cause serious threats to the environment if disposed of without treatment. Throughout the present research, it can be said that a hybrid process including ultrasonic treatment coupled with froth floatation has been shown as a green efficient treatment of oily sludge waste from the bottom of crude oil tanks in Al-Daura refinery and able to get high yield of base oil recovery which is 65% at the optimum operating conditions (treatment time = 30 min, ultrasonic wave amplitude = 60 micron, and (solvent: oily sludge) ratio = 4). Experimental results showed that 83% of the solvent used was recovered meanwhile the main water
... Show MoreGiardia lamblia parasite was isolated from the diarrhea samples of patients with Giardiasis dysentery and was developed in HSP media, four mice groups have been used to find in vivo efficacy of two concentrations (128,256) mg/ml of chlorophorm extracts from Cladophora glomerata algae against Giardia lamblia parasite as compared with (Flagyl) by measuring several biochemical markers as ( GPT and GOT) enzymes ,sodium ,potassium and iron concentration as well as counting the number of parasitic cysts in each mice groups. The results demonstrate that levels of GPTA GOT enzymes have been decreased in mice treated with algal extract. As for the concentration of the Sodium, Potassium and Iron increased in mice treat
... Show MoreThe aim of this study was to evaluate ovarian masses with conventional grey scale ultrasonography and colour Doppler flow imaging and to assess the diagnostic reliability of these methods in differentiating benign and malignant ovarian masses.
We assessed 56 patients with an ovarian mass. Morphological characterisation of the mass was performed utilising the Sassone score. Colour Doppler parameters were recorded for each patient, and the Caruso vascular score was also applied. The results were compared with surgical/pathological and/or follow-up scans.
Using the Sassone score, overall reliability in differentiating ovaria
A rapid and sensitive method for analysis of amino acid hydrolysates of nigella sativa L seed has been developed using O-phthaldialehyde(OPA ) as a pre-column derivatizing agent. OPA reagents in the presence of mercaptoethanol react rapidly with primary amino acids ( less than 60 sec.) to form isindole derivatives which easily separated with good selectivity on ODS column. Resolution of amino acid derivatives is carried out with a methanol gradient in 0.01 maqueous sodium acetate. pH 7.1 . The quantitation of amino acid derivatives is reproducible within an average relative deviation of + 1.4% the linearity for most amino acids were more than 0.9993 with detection limit of 0.2 ppm. 15 amino acid were detected in the analysis of
... Show More