Preferred Language
Articles
/
bsj-2299
Spectrophotometric Determination of Chromium Using Indigo Carmine -Application in Various Samples
...Show More Authors

A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5 -70 µg /25 ml, i.e., 0.02- 2.8 ppm with a molar absorptivity of chromium (VI) 1.71? 104 l.mol-1.cm-1, Sandell’s sensitivity index of 0.0030 µg.cm-2 .The detection limit of chromium was (DL) 0.0012 µg.mL-1 and a relative standard deviation of ? (0.70 -1.86)% depended on the concentration level. The method is developed for the determination of chromium(III) and has been successfully applied to the determination of chromium in various water samples, Pharmaceutical preparations ,standard rock sample of (MRG-1).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The static aging effect on the seedless synthesis of different ranges FAU-type zeolite Y at various factors
...Show More Authors

This work investigates generating of pure phase Faujasite-type zeolite Y at the ranges chosen for this study via a static aging step in the absence of seeds synthesis. Nano-sized crystals may result when LUDOX AS-40 is used as a silica source for gel composition of range 6 and the crystallization step may be conducted for a period of 4 to 19 hr at 100 ⁰C. Moreover, large-crystals with high crystallinity pure phase Y zeolite can be obtained at hereinabove conditions but when hydrous sodium metasilicate is used as a silica source. The other selected ranges also offer pure phase Y zeolite at the same controlled conditions.

View Publication Preview PDF
Crossref (15)
Crossref
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The static aging effect on the seedless synthesis of different ranges FAU-type zeolite Y at various factors
...Show More Authors

This work investigates generating of pure phase Faujasite-type zeolite Y at the ranges chosen for this study via a static aging step in the absence of seeds synthesis. Nano-sized crystals may result when LUDOX AS-40 is used as a silica source for gel composition of range 6 and the crystallization step may be conducted for a period of 4 to 19 hr at 100 ⁰C. Moreover, large-crystals with high crystallinity pure phase Y zeolite can be obtained at hereinabove conditions but when hydrous sodium metasilicate is used as a silica source. The other selected ranges also offer pure phase Y zeolite at the same controlled conditions.

Crossref (15)
Crossref
Publication Date
Tue Oct 24 2023
Journal Name
Chemical Engineering & Technology
Electrodeposition of Manganese Dioxide under Different Conditions: Application of MnO<sub>2</sub>/Carbon Fibers in the Electrosorption Process
...Show More Authors
Abstract<p>Anodic electrodeposition was used to synthesize a composite electrode of nanostructured manganese dioxide/carbon fiber (CF) galvanostatically. Different characterization results of the nanostructured MnO<sub>2</sub> were obtained by varying the H<sub>2</sub>SO<sub>4</sub> concentration and the current density. Field emission scanning electron microscopy, X‐ray diffraction, and atomic force microscopy were utilized to characterize the prepared composite electrodes. The best conditions were: 0.3 mA cm<sup>−2</sup> current density and 0.64 M H<sub>2</sub>SO<sub>4</sub> concentration. The electrosorption performance of the MnO<sub></sub></p> ... Show More
View Publication
Scopus (3)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Determination of Molecular Weight and Viscosity of Irradiated Polystyrene
...Show More Authors

 

The varied applications of polystyrene in various fields of life led to examining the cause of radiation influence on some rheological behavior of commercial Polystyrene (PS) solution in the chloroform (CHCl3) solvent. Polystyrene grains shape samples were irradiated using the radioactive element Cesium- 137 with (9 µci) activity for 10, 20, and 30 minutes. The viscosity of the polymer solution depends on the concentration and size (i.e. molecular weight) of the dissolved polymer. Experimental data showed that the radiation dose affected the value of viscosity (shear, relative, specific, and reduced). The viscosity value significantly reduced at 10 min radiation dose and when increasing the dose, the viscosity value increased

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jun 01 1992
Journal Name
Concrete And Reinforced Concrete
Determination of classes of armature when reinforcement is mixed
...Show More Authors

View Publication
Publication Date
Mon Nov 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of surface treatments and thermocycling on shear bond strength of various artificial teeth with different denture base materials
...Show More Authors

Background: Separation and deboning of artificial teeth from denture bases present a major clinical and labortory problem which affect both the patient and the dentist. The optimal bond strength of artificial teeth with denture base reinforced with nanofillers and flexible denture bases and the effect of thermo cycling should be evaluated. This study was conducted to evaluate and compare the shear bond strength of artificial teeth (acrylic and porcelain) with denture bases reinforced by 5% Zirconium oxide nanofillers and flexible bases under the effect of different surface treatments and thermo cycling and comparing the results with conventional water bath cured denture bases. Material and methods: Two types of artificial teeth; acrylic and

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication
Publication Date
Mon Jan 11 2021
Journal Name
2nd International Conference In Physical Science & Advanced Materials
Comparing the optical parameters for thin CAZTSe films prepared with various Ag ratios and annealing temperatures
...Show More Authors

􀀑􀀃Pure Cu (CZTSe) and Ag dopant CZTSe (CAZTSe) thin films with Ag content of 0.1 and 0.2 were fabricated on coring glass substrate at R.T with thickness of 800nm by thermal evaporation method. Comparison between the optical characteristics of pure Cu and Ag alloying thin films was done by measuring and analyzing the absorbance and transmittance spectra in the range of (400-1100)nm. Also, the effect of annealing temperature at 373K and 473K on these characteristics was studied. The results indicated that all films had high absorbance and low transmittance in visible region, and the direct bang gap of films decreases with increasing Ag content and annealing temperature. Optical parameters like extinction coefficientrefractive index, and

... Show More
Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Alpha Tracks Examination for Female Urine Samples who are Suffering from Urinary Tract Infections
...Show More Authors

Urine samples had been gathered from females living in Baghdad city. The sample consisted of 30 females who suffered from U.T.I (Urinary tract infections) and 20 healthy females. The type of urine U.T.I was specified by the emergency lab in Al-Kindy hospital, and alpha tracks were determined by the nuclear track detector CR-39. The concentrations of alpha in 30 urine samples taken from females who had U.T.I ranged from 0.327ppm-1.583ppm, with an average of 0.94965 ppm. The maximum value 1.583 ppm is belonging to females with an aged 57 years old. The results of healthy female concentration ranged from 0.022 ppm-0.459ppm with an average of (0.30855ppm). The findings revealed that alpha emitter concentrations differed from woman to woman,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Detection of zpx gene of Cronobacter sakazakii isolated from Clinical samples for Iraqi children under Two Years
...Show More Authors

The study included 200 samples were collected from children under two years included (50 samples from each of Cerebrospinal fluid, Blood, Stool and Urine) from, (Central Children Hospital and Children's Protections Educational Hospital) The Iraqi Ministry of Health, the Department of Health Baghdad .the period from the first of 2015 September to the first of December 2015, Were obtained isolates bacterial subjected to the cultural, microscopic and biochemical examination and diagnosed to the species by using vitek2 system .The results showed there were contamination in 6.5% of clinical samples. The diagnosed colonies which gave pink color on the MacConkey agar, golden yellow color on the Trypton Soy agar and green color on t

... Show More
View Publication Preview PDF
Scopus Crossref