With the development of communication technologies for mobile devices and electronic communications, and went to the world of e-government, e-commerce and e-banking. It became necessary to control these activities from exposure to intrusion or misuse and to provide protection to them, so it's important to design powerful and efficient systems-do-this-purpose. It this paper it has been used several varieties of algorithm selection passive immune algorithm selection passive with real values, algorithm selection with passive detectors with a radius fixed, algorithm selection with passive detectors, variable- sized intrusion detection network type misuse where the algorithm generates a set of detectors to distinguish the self-samples. Practical Experiments showed the process to achieve a high rate of detection in the system designer using data NSL-KDD with 12 field without vulnerability to change the radius of the detector or change the number of reagents were obtained as the ratio between detection (0.984, 0.998, 0.999) and the ratio between a false alarm (0.003, 0.002, 0.001). Contrary to the results of experiments conducted on data NSL-KDD with 41 field contact, which affected the rate of detection by changing the radius and the number of the detector as it has been to get the proportion of uncovered between (0.44, 0.824, 0.992) and the percentage of false alarm between (0.5, 0.175, 0.003).
The introduction of Industry 4.0, to improve Internet of Things (IoT) standards, has sparked the creation of 5G, or highly sophisticated wireless networks. There are several barriers standing in the way of 5G green communication systems satisfying the expectations for faster networks, more user capacity, lower resource consumption, and cost‐effectiveness. 5G standards implementation would speed up data transmission and increase the reliability of connected devices for Industry 4.0 applications. The demand for intelligent healthcare systems has increased globally as a result of the introduction of the novel COVID‐19. Designing 5G communication systems presents research problems such as optimizing
This study evaluated yellow mealworm (Tenebrio molitor) larvae meal as an alternative animal-protein ingredient in diets for common carp (Cyprinus carpio) fingerlings. Two diets were compared for 60 days: a conventional fish-meal diet (T1; 32.09% crude protein) and a diet in which the animal-protein component was replaced weight-for-weight with T. molitor meal (T2; 23.88% crude protein). Each treatment was tested in duplicate tanks containing 28 fingerlings per tank, and growth was assessed over three consecutive 20-day phases. The initial mean body weight was 3.21 g. Weight gain differed significantly between treatments (p < 0.05), with the highest total value recorded in T2 (4.87 ± 0.47 g). The T2 diet produced a significantly higher fee
... Show MoreKE Sharquie, AA Noaimi, BA Saleh, Journal of Cosmetics, Dermatological Sciences and Applications, 2016 - Cited by 15
The steady state laminar mixed convection and radiation through inclined rectangular duct with an interior circular tube is investigated numerically for a thermally and hydrodynamicaly fully developed flow. The two heat transfer mechanisms of convection and radiation are treated independently and simultaneously. The governing equations which used are continuity, momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C) methods. The finite difference approach with the Line Successive Over-Relaxation (LSOR) method is used to obtain all the computational results. The (B.F.C) method is used to generate the grid of the problem. A computer program (Fortran
... Show MoreKE Sharquie, MM Al-Waiz, AA Al-Nuaimy, Saudi medical journal, 2005 - Cited by 8
This work is licensed under a Creative Commons Attribution 4.0 International License. Abstract This study examines the working capital management
ABSTRACT: BACKGROUND: Arthroscopic knee surgeries are performed in very large numbers worldwide, and in spite of relatively low complication rate, but the total number is significant. Some of these complications are due to tourniquet use and can be serious. OBJECTIVE: Is to asses if automated pump (with or without) dilute epinephrine saline irrigation can replace the tourniquet use in soft tissue arthroscopic knee surgeries. PATIENTS AND METHODS: 36 patients (9 females 25 % and 27 males 75 %) were included in this prospective experimental nonrandomized study, and were necessitated soft tissue arthroscopic knee surgeries. Patients were divided into two groups, in group A (patients) tourniquet and automated pump were used. In group B (18 pati
... Show MoreThe steady state laminar mixed convection and radiation through inclined rectangular duct with an interior circular tube is investigated numerically for a thermally and hydrodynamicaly fully developed flow. The two heat transfer mechanisms of convection and radiation are treated independently and simultaneously. The governing equations which used are continuity, momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C) methods. The finite difference approach with the Line Successive Over-Relaxation (LSOR) method is used to obtain all the computational results. The (B.F.C) method is used to generate the grid of the problem. A computer program (Fortr
... Show More