The radon gas concentration in environmental samples soil and water of selected regions in Al-Najaf governorate was measured by using alpha-emitters registrations which are emitted form radon gas in (CR-39) nuclear track detector. The first part is concerned with the determination of radon gas concentration in soil samples, results of measurements indicate that the highest average radon concentration in soil samples was found in (Al-Moalmen) region which was (100.0±7.0 Bq/m3), while the lowest average radon concentration was found in (Al-Askary) region which was (38.5±4.7 Bq/m3), with an average value of (64.23±14.9 Bq/m3) ,the results show that the radon gas concentrations in soil is below the allowed limit from (ICRP) agency which is (200 Bq/m3), while the radon exhalation rate (RER) ranged from (35.23-91.52 µBq/m2h), and average value which was (58.77±13.6 µBq/m2h). The second part is concerned with the determination of radon gas concentration in samples of tap water obtained from networks in dwellings in Al-Najaf governorate, the results indicate that the highest average radon concentration in water samples was found in (Meassan) region which was (0.59±0.08 Bq/L), while the lowest average radon concentration was found in (Al-Jamhorah) region which was (0.16±0.04 Bq/L), with an average value of (0.36±0.1 Bq/L), the present results show that the radon gas concentrations in tap water is below the allowed limit from (ICRP) agency which is (0.5994 Bq/L), while the radon exhalation rate (RER) ranged from (2.15-0.58 ?Sv/y), and average value which was (1.28±0.31 ?Sv/y).
Occurrence the heavy metals in water is one of the most important concerns. may cause savior health problems. In this work we made an attempt to know the quantity of six heavy metals in groundwater in different locations of Baghdad city. Examinations were made on groundwater of the review region to assess the heavy metals. Groundwater samples were gathered and analyzed utilizing Atomic Absorption Spectrophotometer for their Manganese, Iron, Zinc, Cadmium, Copper and Lead content and their levels compared with World Health Organization (WHO) specified maximum contaminant level. In order to accomplish this, water samples were obtained from 10 randomly selected wells in the region, in February and August, 2016. The study showed that the ground
... Show MoreThe distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro
... Show MoreThe increase in obesity and the many accompanying diseases is attributed to the increased production and consumption of foods made of non-nutritive sweeteners without regard to the risks of consuming additional calories, and this in turn leads to hormonal imbalance and metabolic disorders and the resulting imbalance and ill health that have spread to all segments of society. During the research, 0.01, 0.02, 0.03, 0.04 and 0.05 % of stevia sweetener was added to the cream instead of the sugar used. Physical and chemical tests were performed for the stevia extract and the microbial content in the cream, as well as the sensory evaluation. It was noted that fortifying the cream with calorie-free stevia sugar led to the production of
... Show MoreObjectives: To highlight the knowledge of Al-Kindy medical students regarding varicella infection and to assess their knowledge and attitude toward its prevention. Methodology: This descriptive cross-sectional study enrolled academic year 2020/2021 students at Al-Kindy College of Medicine from first to final year. We used an online questionnaire by Google forms to collect data, which were analyzed with SPSS 26. Results: A total of 208 students participated with 126 in the preclinical and 82 in the clinical grades. Generally, most clinical students were more aware about epidemiology, clinical manifestations, and complications of varicella infection than the preclinical students. Conclusion: Educational stage is a significant variab
... Show MoreBackground: Data on the impact of neonatal and total pediatric admissions volume on neonatal mortality are sparse. Objectives: This study is done to estimate the neonatal mortality in relation to neonatal admissions and to total hospital admissions in Al-Alwyia Pediatric Teaching Hospital through years 2005-2012 Type of the study: A retrospective study.Methods: statistical records of all cases admitted to APTH were studied during 2005-2012.Results: Neonatal mortality decreased to the nadir at last year of study period (2012) and reached 6.1% of neonatal admissions compared to 2005 level which was 9.7 %. Mortality rate among premature and low birth weight (LBW) infants decreased also. The study also reveals that neonatal mortality constit
... Show MoreThe fall angle of sun rays on the surface of a photovoltaic PV panel and its temperature is negatively affecting the panel electrical energy produced and efficiency. The fall angle problem was commonly solved by using a dual-axis solar tracker that continually maintains the panel orthogonally positioning to the sun rays all day long. This leads to maximum absorption for solar radiation necessary to produce maximum amount of energy and maintain high level of electrical efficiency. To solve the PV panel temperature problem, a Water-Flow Double Glazing WFDG technique has been introduced as a new cooling tool to reduce the panel temperature. In this paper, an integration design of the water glazing system with a dual-axis tracker has been ac
... Show MoreGas hydrate formation is considered one of the major problems facing the oil and gas industry as it poses a significant threat to the production, transportation and processing of natural gas. These solid structures can nucleate and agglomerate gradually so that a large cluster of hydrate is formed, which can clog flow lines, chokes, valves, and other production facilities. Thus, an accurate predictive model is necessary for designing natural gas production systems at safe operating conditions and mitigating the issues induced by the formation of hydrates. In this context, a thermodynamic model for gas hydrate equilibrium conditions and cage occupancies of N2 + CH4 and N2 + CO4 gas mix