The present work involved a study the effect of cobalt(II) complex with formula [CoL(H2O)NO3] .4ETOH where L=Nitro [5-(P-nitro phenyl) -4-phenyl-1,2,4 traizole-3-dithiocarbamato hydrazide] aqua. (4) Ethanol and anti-cancer drug - cyclophosphamide on specific activity of two liver enzymes (GPT,ALP) by utilizing an in vivo system in female mice. On the enzymatic level an inhibition in the activity of GPT was noticed in different body organs such as liver, kidney and lung. The inhibition was noticed in both test and cyclophosphamide drug (cp). Mice were treated with three doses of cyclophosphamide (90,180, 250) ?g/ mouse for three days. The same doses were used for the cobalt (II) complex. The liver shows the highest rate of(GPT) inhibition compared to other organs. The ratio was about 90% at three doses of cobalt (II) complex, this ratio was similar to ratio inhibition of cyclophosphamide at the same doses. On the contrary the enzyme ALP showed high activation in different organs such as liver, kidney and lung in both groups, test and cyclophosphamide drug (cp) at the three doses (90, 180, 250) ?g /mouse. The result showed the highest ratio of activation in the kidney comparable with other organs. The maximum activation of cobalt(II) complex was about 1198% at a concentration 180µg/mouse.There are significant differences(P<0.05) for two treatment when the concentration was increased.
solation of candida spp. From cancer patients who suffered oral candidiasis due to immunodeficiency
Objective(s): To assess the burden of mothers` care for child with colostomy and find out relationships between child and mother socio-demographic data with mothers` burden. Methodology: a descriptive study was conducted from 1 August 2013 to 1 September 2014. The sample consisted of 100 children and their mothers at Baghdad Teaching hospital in Baghdad city. A questionnaire was prepared based on the previous literature review, meeting mothers of children with colostomy, and the Zarit Burden Interview scale. Data has collected through the application of questionnaire and interview techniques. Results: T
For more than a decade, externally bonded carbon fiber reinforced polymer (CFRP) composites successfully utilized in retrofitting reinforced concrete structural elements. The function of CFRP reinforcement in increasing the ductility of reinforced concrete (RC) beam is essential in such members. Flexural and shear behaviors, ductility, and confinement were the main studied properties that used the CFRP as a strengthening material. However, limited attention has been paid to investigate the energy absorption of torsion strengthening of concrete members, especially two-span concrete beams. Hence, the target of this work is to investigate the effectiveness of CFRP-strengthening technique with regard to energy absorption of two-span RC
... Show MoreIn this research the behavior of reinforced concrete columns with large side openings under impact loads was studied. The overall cross sectional dimensions of the column specimens used in this research were (500*1400) mm with total height of (14000) mm. The dimensions of side openings were (600*2000) mm. The column was reinforced with (20) mm diameter in longitudinal direction, while (12) mm ties were used in the transverse direction. The effect of eccentric impact loads on the horizontal and vertical displacement for this column was studied. &
... Show MoreAn experimental program was conducted to determine the residual of composite Steel Beams-Reinforced Concrete (SB-RC) deck floors fabricated from a rolled steel beam topped with a reinforced concrete slab, exposed to high temperatures (fire flame) of 300, 500, and 700ºC for 1 hour, and then allowed to cool down by leaving them in the lab condition to return to the ambient temperature. The burning results showed that, by exposing them to a fire flame of up to 300ºC, no serious permanent deflection occurred. It was also noticed that the specimen recovered 93% of 19.2 mm of the deflection caused by burning. The recovered deflection of burned composite SB-RC deck floor at 500ºC was 40% of 77.9 mm of the deflection caused by burning with a res
... Show MoreTo promote sustainable steel-concrete composite structures, it is essential to develop special shear connectors that facilitate accelerated construction and deconstruction. A lockbolt demountable shear connector (LBDSC) was recently proposed. While the LBDSC has been evaluated using horizontal and vertical (standard) push-out tests, it is essential to further assess the disassembly mechanism and the positive flexural performance of prefabricated demountable composite beams (PDCBs) under both serviceability and ultimate limit states. Two full-scale test specimens of PDCBs with LBDSC were designed with partial shear connections and assessed using a three or four-point load beam setup under both cyclic and static monotonic loading conditions.
... Show MoreObjective: The aim of this study is to determine the factors affecting birth space interval in a sample of women.
Methodology: A cross-sectional study conducted in primary health centers in Al-Tahade and Al- Shak Omar in
Baghdad city. Data were collected by direct interview using questionnaire especially prepared for the study.
Sample size was (415) women in age group (20-40) years who were chosen randomly.
Results: Analysis of data shows highest rate of women (31.8%) had a birth space interval of (8-12) months
followed by (26.7%) had a birth space interval of (19-24) months, (20.2%) had a birth space interval of (>24)
months and (16.1%) had a birth space interval of (13-18) months respectively, while lower rate of w