Preferred Language
Articles
/
bsj-2075
Separation and Determination of Some Organic Acids in Dry Calyces of Iraqi Hibiscus Sabdariffa Linn
...Show More Authors

A new reversed phase- high performance liquid chromatographic (RP-HPLC) method with Ultraviolet-Visible spectrophotometry has been optimized and validated for the simultaneous extraction and determination of organic acids present in Iraqi calyces of Hibiscus Sabdraffia Linn. The method is based on using ultrasonic bath for extracting organic acids. Limit of detection in µg/ml of Formic acid, Acetic acid, Oxalic acid, Citric acid, Succinic acid, Tartaric acid, and Malic acid 126.8498×10-6, 113.6005×10-6, 97.0513×10-6, 49.7925×10-6, 84.0753×10-6, 92.6551×10-6, and 106.1633×10-6 ,respectively. The concentration of organic acids found in dry spacemen of calyces of Iraqi Hibiscus Sabdraffia Linn. under study: Formic acid, Acetic acid, Oxalic acid, Citric acid, Succinic acid, Tartaric acid, and Malic acid are 114.896 µg/g, 64.722 µg/g, 342.508 µg/g, 126.902 µg/g, 449.91 µg/g, 268.52 µg/g, and 254.07 µg/g respectively.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 29 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The impact of operational risks in electronic banking In the light of the principles of Basel (II): An Empirical Study in some Iraqi banks
...Show More Authors

Banks represents financial institutions that influence the economy of any country and their evolution and development is the need to seek all states , communities, maintain and control a guarantee of the beneficiaries investors and to promote confidence, so the specialized organizations trying to set principles and rules must be adhered to and are Basel (II) of the necessary effects to be introduced and work on their application.  Banks exposed by various risks one of them operational risks that have multiple effects on the activity of the institution itself, as well as the national economy, so this study was to find out what those effects and to find solutions and appropriate proposals to avoid Iraqi banks from the effects of risk,

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 30 2018
Journal Name
Iraqi Journal Of Physics
Determination of radioactive concentrations in Tigris river soil samples in Baghdad province
...Show More Authors

In this study, the amounts of activity concentrations of naturally occurring in 10 soil samples of the Tigris river and surrounding areas collected from deferent city of Baghdad have been investigated. Tigris river is an important water source for irrigation and drinking in Iraq. This study was done during 2018 in Protection Center of the Iraqi Ministry of Health and Environment using a high purity germanium detector. The resolution of (HPGe) at 2keV and 30% efficiency. The results of soil sample obtained showed that the effective activity concentration of 40K are ranged from 181.4 Bq/kg in sample S6 to 286.4 Bq/kg in S7. For Raeq values are ranged from 6 Bq/m3 in sample S5 to 17 Bq/m3 in sample S3. The obtained data revealed that the me

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 16 2021
Journal Name
International Journal For Computational Methods In Engineering Science And Mechanics
Determination of time-dependent coefficients in moving boundary problems under nonlocal and heat moment observations
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Flame Atomic Emission and Colorimetric Methods for the Determination of Cephalexin Monohydrate in Pharmaceutical Preparations
...Show More Authors

We propose two simple, rapid, and convenient spectrophotometric methods which are described for the determination of cephalexin in bulk and its pharmaceutical preparations. They are based on the measurement of the flame atomic emission of potassium ion (in the first method) and colorimetric determination of the green colored solution at 610 nm formed after the reaction of cephalexin with potassium permanganate as an oxidant agent (in the second method) in basic medium. The working conditions of the methods are investigated and optimized. Beer's law plot shows a good correlation in the concentration range of 5-40?g ml-1. The detection limits are 2.573,2.814 ?g ml-1 for the flame emission photometric method and 1.844,2.016 ?g ml-1 for colo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with Arsenazo(III) Reagent in Water samples and Veterinary Preparation
...Show More Authors

A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 21 2020
Journal Name
Baghdad Science Journal
Spectrophotometer Determination of Cefixime in pure form and pharmaceutical preparation by Using Cloud point Extraction
...Show More Authors

Two simple methods spectrophotometric were suggested for the determination of Cefixime (CFX) in pure form and pharmaceutical preparation. The first method is based without cloud point (CPE) on diazotization of the Cefixime drug by sodium nitrite at 5Cº followed by coupling with ortho nitro phenol in basic medium to form orange colour. The product was stabilized and measured 400 nm. Beer’s law was obeyed in the concentration range of (10-160) μg∙mL-1 Sandell’s sensitivity was 0.0888μg∙cm-1, the detection limit was 0.07896μg∙mL-1, and the limit of Quantitation was 0.085389μg∙mL-1.The second method was cloud point extraction (CPE) with using  Trtion X-114 as surfactant. Beer

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
Indirect Flow Injection Spectrophotometric and Chromatographic Methods for the Determination of Mebendazole in Pharmaceutical Formulations
...Show More Authors

Chromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hy

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jan 05 2019
Journal Name
Iraqi Journal Of Physics
The effect of heat treatment on the optical properties of organic semiconductor (NiPc/C60) thin films
...Show More Authors

Thin films of the blended solution of (NiPc/C60) on glass substrates were prepared by spin-coated method for three different ratios (100/1, 100/10 and 100/100). The effects of annealing temperature and C60 concentration on the optical properties of the samples were studied using the UV-Vis absorption spectroscopy and FTIR spectra. The optical absorption spectrum consists of two main bands, Q and B band, with maxima at about (602-632) nm and (700-730) nm for Q1 and Q2 respectively, and (340-375) nm for B band. The optical energy gap were determined from optical absorption spectra, The variation of optical energy gap with annealing temperature was nonsystematic and this may be due to the improvement in crystal structure for thin films. Whi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 01 2025
Journal Name
Al-khwarizmi Engineering Journal
Object Dimension and Location Determination in Gantry Robots and Conveyor Systems: A Review
...Show More Authors

A​‍​‌‍​‍‌ gantry robot is one of the most common types of industrial robots with linear movement. This type of robot is also known as a Cartesian or linear robot. It is an automated industrial system that moves along linear paths, enabling it to create a 3D envelope of the space in which it operates. A robot of this type has a standardised configuration process because it can have several sets of axes, such as X, Y and Z. The gantry robot picks up products from several places, so it can search through various locations. Afterwards, it carefully deposits the products on a conveyor belt for the next stage of the procedure or final ​‍​‌‍​‍‌shipment. This integration enables continuous and automated material flow

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Studying the Effect of Adding Doekhla kaolin Clay and Alumina to Iraqi Bauxite on Some Physical and Mechanical and Thermal Properties
...Show More Authors

The aim of this work is to produce samples from Iraqi raw materials like Husyniat Bauxite (raw and burnt) and to study the effect of some additives like white Doekhla kaolin clays and alumina on that material properties were using sodium silica as a binding material. Five mixtures were prepared from Bauxite (raw and burnt) and kaolin clays, with an additive of (40) ml from sodium silica and alumina of (2.5, 5, 7.5,10 wt %) percentage as a binding material. the size grading was through sieving. The formation of all specimens was conducted by a measured gradually semi-dry pressing method under a compression force of (10) Tons and humidity ratio ranging from (5-10) % from mixture weight. Drying all specimens was done and then they were burn

... Show More
View Publication Preview PDF