Objective: In this study ,the effects of silver nanoparticles (Ag NPs)were investigated on the liver and kidney tissues. Methodology: The produced nanoparticles have an average particle size of about 30 nm. Eighteen male albino rats were used by dividing them into three groups, each group comprise 6 rats. First group(control group) given food and water like other groups by liberty. Second group was tail injected by (AgNPs) at dose of (0.4 mg/kg. body weight/day). Third group was injected by (AgNPs) at dose of (0.6 mg/kg. body weight/day) for 15 days. All animals were sacrified at the end of experiment. The liver and kidney tissues specimens were fixed in 10% formalin and histological preparations were carried out then stained with H&E. Pathological changes in liver and kidney tissues were showed. Results: Histopathological studies revealed the harmful effect of the silver nanoparticles uses on the liver and kidney rats, second group that treated with Ag NPs (0.4 mg/kg.body.weight/day), kidney sections showed enlargement of collecting tubules, increase in interstitial tissue medulla, necrosis and enlargement in proximal and distal convoluted tubules. Liver showed enlargement of the central vein and degeneration of hepatic cells. Third group that treated with Ag NPs (0.6 mg/kg. body weight/day); kidney sections showed hyperplasia of the interstitial connective tissue of renal medulla with hemorrhages, renal cortex showed, degenerative changes and necrosis of proximal and distal convoluted tubules. Liver section showed congestion and necrosis of hepatic cells. Conclusion: Silver nanoparticles cause damage in liver and kidney tissues. Recommendation: Further study is needed for the effect of Ag NPs on the other tissues.
Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were
... Show MoreDiesel engine oil was subjected to thermal oxidization (TO) for six periods of time (0 h, 24 h, 48 h, 72 h, 96 h, and 120 h) and was subsequently characterized by terahertz time domain spectroscopy (THz-TDS). The THz refractive index generally increased with oxidation time. The measurement method illustrated the potential of THz-TDS when a fixed setup with a single cuvette is used. A future miniaturized setup installed in an engine would be an example of a fixed setup. For the refractive index, there were highly significant differences among the oxidation times across most of the 0.3–1.7 THz range.
Purpose: the purpose of this study is to investigate how managers working for the General Authority for Irrigation and Reclamation Projects react to the impact of Emotional Intelligence (EI) on their performance. Theoretical framework: The current study includes an intellectual framework on two variables, namely EI and Manager Performance (MP), because it is essential to investigate the relationship between these two variables and the impact of EI on MP. Design/methodology/approach: The research problem is that a manager's capacity to make wise decisions about their work or interactions with subordinates is diminished when they have inadequate EI. The questionnaire is used as a tool for gathering data for the study, and the st
... Show Morehe present work, among other previous studies done in our lab, aimed to highlight the histopathological effect of S. xylosus peptidoglycan in comparison to LPS of E. coli. Materials and methods: One hundred and fifty urine specimens were collected from urinary tract infection patients visiting Baghdad hospitals. The histopathological effects of S. xylosus S24 peptidoglycan was studied in the urinary tract of female mice by injecting 5 animal groups at the following concentrations: 1000, 2000, 3000, 4000, and 5000 µg/mL. Another 5 groups were injected with 10, 25, 50, 75, and 100 ng/mL of E. coli (serotype 0128:B12) LPS. Results: Ten isolates were confirmed to be Staphylococcus xylosus. Histopathological study showed different pathological
... Show MoreThis study included estimation of glutathione (GSH) and Malondialdehyde (MDA) levels in the serum of diabetic patients type II who are treated with a polyherbs mixture (Nigella sativa, Trigonella foenum-graeum, Cyperus rotundus and Teucrium polium) for three months of treatments. Seventy samples of diabetic patients Type II male and females with age about (35-60) years were taken including 44 samples for group one (24 male, 20 female) who used herbs accompanied with chemical treatment (drugs) and 26 samples for the second group (13male and 13 female) who used herbs only. These groups were compared with 60 samples obtained from healthy persons (29 male, 31 female) at the same age of patients as a control group. Effect of age and treatment fo
... Show MoreTitanium dioxide nanotubes were synthesized by anodizing Ti sheets in the ethylene glycol solution and were covered in Pt nanoparticles onto the surface of TiO2NTs using electrodeposition method from using five derivatives of Mannich base Pt complexes which have been used as precursor of platinum. The mean size, shape, elemental composition of the titanium dioxide nanotubes and platinum deposited on the template were evaluated by different techniques such as field emission scanning electron microscope (FE-SEM), transmission electron microscopy (TEM), X-ray diffraction pattern (XRD), and energy dispersive X-ray (EDX) technique. From all these analyses, the TiO2NTs prepared and Ptnanoparticles deposited on it were ide
... Show MoreThe electronic properties (such as energy gap HOMO levels. LUMO levels, density of state and density of bonds in addition to spectroscopic properties like IR spectra, Raman spectra, force constant and reduced masses as a function of frequency) of coronene C24 and reduced graphene oxide C24OX , where x=1-5, were studied.. The methodology employed was Density Functional Theory (DFT) with Hybrid function B3LYP and 6-311G** basis sets. The energy gap was calculated for C24 to be 3.5 eV and for C24Ox was from 0.89 to 1.6862 eV for x=1-5 ,respectively. These energy gaps values are comparable to the measured gap of Graphene (1-2.2 eV). The spectroscopic properties were compared with experimental measurements, specificall
... Show MoreThe purpose of this paper is to gain a good understanding about wake region behind the car body due to the aerodynamic effect when the air flows over the road vehicle during its movement. The main goal of this study is to discuss the effect of the geometry on the wake region and the aerodynamic drag coefficient. Results will be achieved by using two different shapes, which are the fastback and the notchback. The study will be implemented by the Computational Fluid Dynamic (CFD) by using STAR-CCM+® software for the simulation. This study investigates the steady turbulent flow using k-epsilon turbulence model. The results obtained from the simulation show that the region of the air separation behind the vehicle
... Show MoreBackground: Alterations in the microhardness and roughness are commonly used to analyze the possible negative effects of bleaching products on restorative materials. This in vitro study evaluated the effect of in-office bleaching (SDI pola office +) on the surface roughness and micro-hardness of four newly developed composite materials (Z350XT –nano-filled, Z250XT-nano-hybrid, Z250-mico-hybrid and Silorane-silorane based). Materials and methods: Eighty circular samples with A3 shading were prepared by using Teflon mold 2mm thickness and 10mm in diameter. 20 samples for each material, 10 samples for base line measurement (surface roughness by using portable profillometer, and micro-hardness by usingDigital Micro Vickers Hardness Test
... Show More