Preferred Language
Articles
/
bsj-2000
Design and study for transmitter system of laser Nd-YAG (1.06 ?m)
...Show More Authors

In this research , design and study a (beam expander) for the Nd – YAG laser with (1.06 ?m) Wavelength has been studied at 5X zoom with narrow diversion in the room temperature. by using (ZEMAX) to study the system. Evaluate its performance via (ZEMAX) outputs, as bright Spot Diagram via (RMS), Ray Fan Plot, Geometric Encircled Energy and the value of Focal shift. Then study the effect of field of view on the outputs in the room temperature.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
A Proposed Agent System for Network Monitoring
...Show More Authors

The traditional centralized network management approach presents severe efficiency and scalability limitations in large scale networks. The process of data collection and analysis typically involves huge transfers of management data to the manager which cause considerable network throughput and bottlenecks at the manager side. All these problems processed using the Agent technology as a solution to distribute the management functionality over the network elements. The proposed system consists of the server agent that is working together with clients agents to monitor the logging (off, on) of the clients computers and which user is working on it. file system watcher mechanism is used to indicate any change in files. The results were presente

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Computational Thermal Sciences: An International Journal
EXPERIMENTAL AND NUMERICAL ANALYSIS FOR THERMAL PROBLEM OF FRICTIONAL BRAKE SYSTEM
...Show More Authors

The present work aims to validate the experimental results of a new test rig built from scratch to evaluate the thermal behavior of the brake system with the numerical results of the transient thermal problem. The work was divided into two parts; in the first part, a three-dimensional finite-element solution of the transient thermal problem using a new developed 3D model of the brake system for the selected vehicle is SAIPA 131, while in the second part, the experimental test rig was built to achieve the necessary tests to find the temperature distribution during the braking process of the brake system. We obtained high agreement between the results of the new test rig with the numerical results based on the developed model of the brake

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Mar 07 2018
Journal Name
International Journal Of Applied Pharmaceutics
FORMULATION AND CHARACTERIZATION OF LAFUTIDINE NANOSUSPENSION FOR ORAL DRUG DELIVERY SYSTEM
...Show More Authors

Objective: The objective of this study was to prepare nanosuspension of a practical water insoluble antiulcer drug which is lafutidine to enhance the solubility, dissolution rate with studying the effect of different formulation variables to obtain the best formula with appropriate physical properties and higher dissolution rate.Methods: Nanosuspension of lafutidine was prepared using solvent anti-solvent precipitation method using Polyvinylpyrrolidone K-90(PVP K-90) as the stabilizer. Ten formulations were prepared to show the effect of different variables in which two formulations showed the effect of stabilizer type, three formulations showed the effect of stabilizer concentration, two formulations showed the effect of combinatio

... Show More
View Publication
Scopus (27)
Crossref (14)
Scopus Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Gingival Enlargement Management using Diode Laser 940 nm and Conventional Scalpel Technique (A Comparative Study)
...Show More Authors

Diode lasers are becoming popular in periodontal surgery due to their highly absorption by pigments such as melanin and hemoglobin their weak absorption by water and hydroxyapatite makes them safe to be used around dental hard tissues. Objective: The aim of the present study was to evaluate the efficiency of diode laser in performing gingivectomy in comparison to conventional scalpel technique in patients with chronic inflammatory enlargement. Materials and methods: Thirty patients were selected for this study. All of them required surgical treatment of gingival enlargements and were randomly divided into two groups: Control group (treated by scalpel and include sixteen patients) and study group (treated with diode laser 940nm and includ

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 01 2022
Journal Name
Neuroquantology
Reaction Cross Section Variations of (alpha + 22Ne) in Msun<M<4Msun AGB Stars
...Show More Authors

Listed

Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
A Study of the Spectroscopic Performance of Laser Produced CdTe(x):S(1-x) Plasma
...Show More Authors

Abstract

In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3  have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 10 2010
Journal Name
Iraqi Journal Of Laser
Improvement of Nonlinear Optical Properties for Mixture Laser Dyes Doped PMMA
...Show More Authors

The spectral characteristics and the nonlinear optical properties of the mixed donor (C-480) acceptor (Rh-6G) have been determined. The spectral characteristics are studied by recording their absorption and fluorescence spectra. The nonlinear optical properties were measured by z-scan technique, using Q-switched Nd: YAG laser with 1064 nm wavelength. The results showed that the optimum concentration of acceptor is responsible for increasing the absorption and the emission bandwidth of donor to full range and to 242 nm respectively by the energy transfer process, also the efficiency of the process was increased by increasing the donor and acceptor concentration. The obtained nonlinear properties results of the mixture C-480/ Rh-6G showed

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Pulsed Er,Cr:YSGG Laser For Surface Modification of Dental Zerconia Ceramic
...Show More Authors

Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG  Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Reconstruction of 3D Shape for an Object using Laser Scanning Triangulation
...Show More Authors

This paper presents a method of designing and constructing a system capable of acquiring
the third dimension and reconstructs a 3D shape for an object from multi images of that object using
the principle of active optical triangulation. The system consists of an illumination source, a photo
detector, a movement mechanism and a PC, which is working as a controlling unit for the hard ware
components and as an image processing unit for the object multi view raw images which must be
processed to extract the third dimension. The result showed that the optical triangulation method
provides a rapid mean for obtaining accurate and quantitative distance measurements. The final
result's analysis refers to the necessity of usin

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Results In Engineering
Low-cost autonomous car level 2: Design and implementation for conventional vehicles
...Show More Authors

View Publication
Scopus (32)
Crossref (32)
Scopus Clarivate Crossref