This research is dealing with five sample of tomato ketchup products available in local market that were respectively as follows: Hello-Baghdad Iraq, Tiffany-Abu Dhabi, Melody-Dubai, Baidar-Saudi Arabia, and Altunsa-Turkey. Also it is dealing with four sample of sauce products available in local market that were respectively as follows: Hello-Baghdad, Iraq, Al-Badawi-Baghdad Iraq, Family-Baghdad, Iraq, and Hala-Amman Jordon. Analysis was performed on each sample three times and mean of the reading was taking. Samples were tested through terse and shorthand from lengthened steps. The spectrophotometric method used rely on theoretical and practical bases in extraction and diagnosis by UV spectrophotometer. This method in short notes, consisted of achievement of extraction of the ketchup and sauce aqueous solution in three steps from which benzoic acid extracted in the form of benzoate, through these steps the benzoate form was changed into benzoic acid form, so the sample aqueous solution extracted using diethyl ether and its quantity was transferred by volume. The UV absorbance curve for benzoic acid was drawn in spectral range 200-290 nm, and the spectra for benzoic acid 250-290 nm was also drawn, whereas in this range the higher absorbance at 272 nm was predicted, and the final benzoic acid solution was tested using UV spect. at this proper wavelength, so the benzoic acid reading was obtained using acid standard curve utilization. In this work was also noticed that pH values for ketchup and sauce products are differed and ranging from 2 to 5 instead of the stated values that must be between 3.5 to 4.7. The higher recorded benzoic acid concentrations in ketchup samples in this work was higher as 1315 and lower as 745 mg/Kg, and it recorded a value 255 mg/Kg which approaches allowable value stated by Iraqi standardization (250 mg/Kg). Whereas the higher recorded benzoic acid concentrations in sauce samples in this work was higher as 2695 mg/Kg, and some of which recorded a value 280 mg/Kg which approaches allowable value stated by Iraqi standardization (250 mg/Kg). In general terms the concentration levels in samples investigated were higher than allowable value stated by Iraqi standardization (250 mg/Kg).
The essay discusses how different environmental factors affect plant growth by explaining how each factor affects the physiological processes within the plant. The essay begins by explaining the effect of temperature on plant growth, as high or low temperatures can significantly affect the rate of photosynthesis and lead to a reduction in water and nutrient absorption. It also discusses the light intensity impacting plants because the more appropriate the light intensity is, the more enhanced the plant's photosynthesis ability, and in the excess or insufficient light condition, the growth can be inhibited. Additionally, the article outlines the effect of water shortage on the plant because this leads to the closure of stomata to avoid water
... Show MoreThe 3D electro-Fenton technique is, due to its high efficiency, one of the technologies suggested to eliminate organic pollutants in wastewater. The type of particle electrode used in the 3D electro-Fenton process is one of the most crucial variables because of its effect on the formation of reactive species and the source of iron ions. The electrolytic cell in the current study consisted of graphite as an anode, carbon fiber (CF) modified with graphene as a cathode, and iron foam particles as a third electrode. A response surface methodology (RSM) approach was used to optimize the 3D electro-Fenton process. The RSM results revealed that the quadratic model has a high R2 of 99.05 %. At 4 g L-1 iron foam particles, time of 5 h, and
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreThe goal of this investigation is to prepare zinc oxide (ZnO) nano-thin films by pulsed laser deposition (PLD) technique through Q-switching double frequency Nd:YAG laser (532 nm) wavelength, pulse frequency 6 Hz, and 300 mJ energy under vacuum conditions (10-3 torr) at room temperature. (ZnO) nano-thin films were deposited on glass substrates with different thickness of 300, 600 and 900 nm. ZnO films, were then annealed in air at a temperature of 500 °C for one hour. The results were compared with the researchers' previous theoretical study. The XRD analysis of ZnO nano-thin films indicated a hexagonal multi-crystalline wurtzite structure with preferential growth lines (100), (002), (101) for ZnO nano-thin films with different thi
... Show MoreIn this work Study effect of annealing temperature on the Structure
of a-Se and electrical properties of a-Se/c-Si hetrojunction have been
studied.The hetrojunction fabricated by deposition of a-Se film on c-
Si using thermal evaporation.
Electrical properties of a-Se/ c-Si heterojunction include I-V
characteristics, in dark at different annealing temperature and C-V
characteristics are considered in the present work.
C-V characteristics suggested that the fabricated diode was
abrupt type, built in potential determined by extrapolation from
1/C2-V curve. The built - in potential (Vbi) for the Se/ Si System
was found to be increase from 1.21 to 1.62eV with increasing of
annealing temperature
Avascular necrosis have always presented great challenges to orthopedic surgeons and patients, remain in many ways today the unsolved dilemma. Varieties of non-vascularized bone grafting techniques preceded by core decompression have been proposed with varying degrees of success. O bb j ee cc t i vv ee ss : The aim of this study is to review the the value of core decompression and non-vascularized tibial bone strip graft treatment for early stages of non-traumatic osteonecrosis stage II & III according to stein burg staging . M ee t hh oo dd ss : prospectively reviewed 26 patients (32 hips) with osteonecrosis of the femoral head between June 2006 and December 2013 at Imam Ali hospital in Sader city & Al-Wasity teaching hosp
... Show More