This research is dealing with five sample of tomato ketchup products available in local market that were respectively as follows: Hello-Baghdad Iraq, Tiffany-Abu Dhabi, Melody-Dubai, Baidar-Saudi Arabia, and Altunsa-Turkey. Also it is dealing with four sample of sauce products available in local market that were respectively as follows: Hello-Baghdad, Iraq, Al-Badawi-Baghdad Iraq, Family-Baghdad, Iraq, and Hala-Amman Jordon. Analysis was performed on each sample three times and mean of the reading was taking. Samples were tested through terse and shorthand from lengthened steps. The spectrophotometric method used rely on theoretical and practical bases in extraction and diagnosis by UV spectrophotometer. This method in short notes, consisted of achievement of extraction of the ketchup and sauce aqueous solution in three steps from which benzoic acid extracted in the form of benzoate, through these steps the benzoate form was changed into benzoic acid form, so the sample aqueous solution extracted using diethyl ether and its quantity was transferred by volume. The UV absorbance curve for benzoic acid was drawn in spectral range 200-290 nm, and the spectra for benzoic acid 250-290 nm was also drawn, whereas in this range the higher absorbance at 272 nm was predicted, and the final benzoic acid solution was tested using UV spect. at this proper wavelength, so the benzoic acid reading was obtained using acid standard curve utilization. In this work was also noticed that pH values for ketchup and sauce products are differed and ranging from 2 to 5 instead of the stated values that must be between 3.5 to 4.7. The higher recorded benzoic acid concentrations in ketchup samples in this work was higher as 1315 and lower as 745 mg/Kg, and it recorded a value 255 mg/Kg which approaches allowable value stated by Iraqi standardization (250 mg/Kg). Whereas the higher recorded benzoic acid concentrations in sauce samples in this work was higher as 2695 mg/Kg, and some of which recorded a value 280 mg/Kg which approaches allowable value stated by Iraqi standardization (250 mg/Kg). In general terms the concentration levels in samples investigated were higher than allowable value stated by Iraqi standardization (250 mg/Kg).
A detailed experimental study was devoted to the anodic oxidation of oxalic acid using manganese dioxide rotating cylinder anode with the objective to evaluate in a systematic way the effect on the oxalic acid oxidation process of several relevant parameters, including the presence of sodium chloride, the current density (J), the rotation speed, the temperature, and the initial concentration of oxalic acid. Thin manganese dioxide film on graphite substrate has been prepared by electrochemical oxidation from MnSO4-H2SO4 electrolyte. The morphology of this electrode was investigated by XRD, SEM, EDS and AFM techniques. The results show that a firm γ-structure of MnO2 film on graphite rod can be obtained successfully. The results indicate tha
... Show MoreA novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show MoreThe study aimed to purification of acid phosphatase (ACP) from sera of obesetype 2 diabetes mellitus patients, this study included from thirty T2DM patients and thirty control, purification process was done with several steps included precipitation with inorganic salt (NH4 ) 2SO4 30%-80%, dialysis, ion exchange chromatography by DEAE sepharose anion column and size exclusion chromatography by Sepharose 6B.ACP, BMI, FBS, HbA1c, Lipid profile, Urea, Creatinie, Insuline, Homa-IR were determined. Results showed the precipitate and concentrated protein appeared four peaks in ion exchange column. ACP located in the first and second peak with purification fold (21.1), (37.2) yield of enzyme and specific activity (173.3) IU/ml, which obtained a si
... Show MoreA mathematical model was proposed to study the microkinetics of esterification reaction of oleic acid with ethanol over prepared HY zeolite catalyst. The catalyst was prepared from Iraqi kaolin source and its properties were characterized by different techniques. The esterification was done under different temperature (40 to 70˚C) with 6:1 for molar ratio of ethanol to oleic acid and 5 % catalyst loading.
The microkinetics study was done over two period of time each period was examined individually to calculate the reaction rate constant and activation energy. The impact of the mass transfer resistance to the reactant was also investigated; two different studies have been accomplished to do this purpose.
&nb
... Show MoreA mathematical model was proposed to study the microkinetics of esterification reaction of oleic acid with ethanol over prepared HY zeolite catalyst. The catalyst was prepared from Iraqi kaolin source and its properties were characterized by different techniques. The esterification was done under different temperature (40 to 70˚C) with 6:1 for molar ratio of ethanol to oleic acid and 5 % catalyst loading. The microkinetics study was done over two period of time each period was examined individually to calculate the reaction rate constant and activation energy. The impact of the mass transfer resistance to the reactant was also investigated; two different studies have been accomplished to do this purpose. The e
... Show MoreThe aim of this study is to evaluate in-vitro activity of Cefamandol (Cfm) and Ceftazidime (Cfz), in combination with Clavulanic acid (CA) against ten complicated multiresistant uropathogenic E.coli .One hundred clinical strains were isolated from patients with chronic urinary tract infections (UTIs), these isolates were identified by the Api identification systems. The antimicrobial susceptibility tests were determined by Kirby-Bauer method, all of them were sensitive to Imipenem (Imp). Ten strains were chosen for the present study, they were resistant to Ampicillin (Amp), Amoxicillin (Amo), Carbenicillin (Cb), Ticarcillin (Tic), Azlocillin (Azl), Amoxicillin\ Potassium Clavulanate {Augmentin(Amc)}, (Amo\CA), Ticarcillin\ Potas
... Show MoreABSTRACT Porous silicon has been produced in this work by photochemical etching process (PC). The irradiation has been achieved using ordinary light source (150250 W) power and (875 nm) wavelength. The influence of various irradiation times and HF concentration on porosity of PSi material was investigated by depending on gravimetric measurements. The I-V and C-V characteristics for CdS/PSi structure have been investigated in this work too.