A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
The research aims to demonstrate the quality of the auditor’s report by analyzing a number of models represented by the auditor’s report based on the Iraqi audit evidence and the auditor’s report in light of the application of international auditing standards for the report and the auditor’s report in light of the application of the International Auditing Standard 701, in addition to explaining the impact of applying the International Auditing Standard 701. International Auditing 701 in enhancing the quality of the auditor's report, and in order to reach these goals, a comparison was made on international experiences before and after the application of the standard in addition to the results of the questionnaire distribut
... Show MoreThis research sheds light on the contributions of a group of scientific Kurdish scholars in the seventh and eighth Hijri centuries, who devoted themselves to serving science with the bad political and economic conditions at the time, and the research pointed to the flowering of science and how students travel in order to provide them with science, obtain a scientific certificate, then take up The research efforts of the scholars in the two Hijri century mentioned in the science of the Qur’an, whether in the field of recitations, intonation or interpretation, and the research ends with a conclusion in which I mentioned the most important conclusions reached in this research.
the study including isolation and identification of candida spp causing UTIs from patintes coming to al-yarmouk hospital
In this work the corrosion behavior of Al metal was studied by using non- destructive testing (NDT), which is a noninvasive technique for determining the integrity of a material. The ultrasonic waves was used to measure the corrosion which occur by two corrosive medium (0.1N sodium chloride and 0.1N sodium hydroxide) and study the corrosion by weight-loss method and electrochemical method in addition to performance the microscopic inspection for the samples before and after the immersion in the corrosive medium. Corrosion parameters were interpreted in these media which involve corrosion potential (Ecorr) and corrosion current density (icorr). The results indicate that both
... Show More