This study is to evaluate plasma levels of several cytokines in preeclamptic pregnancies compared to those of healthy pregnancies. Ninety pregnant women with preeclampsia (37 mild & 53 severe) and thirty healthy pregnant women were enrolled in the study. Blood samples were taken and plasma levels of IL-8, IL-10, and IFN-? were measured by enzyme-linked immunosorbent assay (ELISA). Preeclamptic women and their severe cases but not mild cases had significantly (P<0.05) increased levels of plasma IL-8, and IFN-? as compared with healthy pregnancies. By contrast, plasma levels of IL-10 was significantly (P<0.05) increased in healthy pregnant women as compared to all groups of preeclampsia. Preeclampsia is associated with an imbalance between pro-inflammatory cytokines (IL-8, IFN-?) and anti-inflammatory cytokines (IL-10), and these support our suggestion of altered immune response in preeclampsia.
Background: In the present study used device jet plasma needle with atmospheric pressure which generates non thermal plasma jet to measure treatment potent with plasma against pathogenic bacteria founded in UTI was inactivated with plasma at 10 sec,
Objective:. This work included the application of the plasma produced from the system in the field of bacterial sterilization , where sample of Gram- negative bacteria (Escherichia coli) were exposed to intervals (1-10)second . Midstream Urine samples swabs were obtained from patients with urinary tract infections.
Type of the study: Cross -sectional study.
Methods: The work were used i
... Show MoreLength of plasma generated by dc gas discharge under different vacuum pressures was studied experimentally. The cylindrical discharge tube of length 2m was evacuated under vacuum pressure range (0.1-0.5) mbar at constant external working dc voltage 1500V. It was found that the plasma length (L) increased exponentially with increasing of background vacuum air pressure. Empirical equation has been obtained between plasma length and gas pressure by using Logistic model of curve fitting. As vacuum pressure increases the plasma length increases due to collisions, ionizations, and diffusions of electrons and ions.
A field experiment was carried out in the College of Agricultural Engineering Sciences - University of Baghdad, during the fall season of 2021 to find out which cultivated cultivars of maize are efficient under nitrogen fertilization. The experiment was applied according to an RCBD (split-plot design with three replications). The cultivars of the experiment (Baghdad, 5018, Sarah) supply three levels of nitrogen fertilizer, which are N1 (100 kg.N/ha), N2 (200 kg.N/ha) and N3 (300 kg.N/ha). The statistical analysis results showed the superiority of the Sarah genotype, which gave the highest value of SOD and CAT enzymes, reaching 11.59 units mg-1 and 10.76 units mg-1 . Protein sequentially, while cultivar5018 outperformed as it gave th
... Show MoreThis research aimes to expose the levels of geometrical thinking among the students of mathematic department in Basic Education College at AL-Mustansiriyah University throughout their respondes on the test of geometrical thinking which consists (50) multi- choice items distributed on the first four levels of Van Hiele ( recognition – analysis – ordering – deduction ).
The validity and the reliability of the test have been investigated. Besides, the difficulty and its discrimination have been measured. The activity of the wrong variables has been measured.
The test has been applied on (180) male and female students of the first, second and third grades.
... Show MoreThis study explains the effect of non-thermal (cold) plasma on wound of diabetic rats by (FE-DBD) system, 3cm probe diameter is used. The output power was ranged from (12-20) W. The effect of non-thermal plasma on wounds of a diabetic was observed with different exposure durations (20,30) sec., the plasma exposure duration decreases the sugar level in blood and the diameter of the wound. These results indicate the cold plasma can be used to enhance the insulin level (i.e., blood sugar) and wounds treatment.
Abstract
In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3 have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r
... Show MoreIn this study, the specimens of land snails Polygyra cereolus (Megerle v on Mühlfeld t , 181 8
(Gastropoda, Stylommatophora, are collected between March and April 2021
from gardens and nurseries in Baghdad province, this species was recorded as a new record to
Iraq molluscan fauna. Description of the most important characteristics, measurements of the
shell are presented with digital p photographs, subsequently, this study represents the first record
of the Polygyridae in Iraq.
Arab-Islamic architecture has undergone a change at multiple levels affected by modern technology, so the research sought to address the role of contemporary technologies on a fundamental and fundamental component of architecture, which is the architectural space, what is known as the essence of architecture and its ultimate destination, with a focus on the architectural space in the architecture of the contemporary Arab Islamic mosque, because the mosque’s architecture is so important in Islamic law and the belief of the Muslim person himself, where the mosque is the functional style produced by the Islamic faith and embodied in it, whereas, knowing the levels of influence of contemporary technologies in the architectural spac
... Show More