Some biological aspects of the zebra mussel, Dreissena polymorpha have been studied at Al-Musayab thermal power plant ,sixty km. south west of Baghdad. Data collected during the period extended from November, 2002 to October, 2003 except for the month of April The population consisted of five age groups; O, I, II, III, and IV which have 0, 1, 2, 3 and 4 annuli respectively. The study also proved the validity of annuli readings for age and growth determination. The average annual growth rates for age groups O,I, II, III, and IV were 5.7, 5.5, 5.4, 5.2 and 5.4 respectively. Average calculated length for laboratory reared mussel was 2.5 mm compared to 5.4 mm in natural environment. Correlation coefficients were very high between age and shell length, shell hight and total weight. their respective values were 0.892, 0.929 and0.934. Mature gonads were recognized during March, June and October where sex ratio was determined. Chi-square test showed no statistical difference between the two sexes.By calculating total average weights during months of study, two maturing and spawning periods were noted. The first was in late June and July, the second extended from September through February.
Groundwater can be assessed by studying water wells. This study was conducted in Al-Wafa District, Anbar Governorate, Iraq. The water samples were collected from 24 different wells in the study area, in January 2021. A laboratory examination of the samples was conducted. Geographical information systems technique was relied on to determine the values of polluting elements in the wells. The chemical elements that were measured were [cadmium, lead, cobalt and chromium]. The output of this research were planned to be spatial maps that show the distribution of the elements with respect to their concentrations. The results show a variation in the heavy elements concentrations at the studied area groundwater. The samples show different values
... Show MoreThe paper presents a highly accurate power flow solution, reducing the possibility of ending at local minima, by using Real-Coded Genetic Algorithm (RCGA) with system reduction and restoration. The proposed method (RCGA) is modified to reduce the total computing time by reducing the system in size to that of the generator buses, which, for any realistic system, will be smaller in number, and the load buses are eliminated. Then solving the power flow problem for the generator buses only by real-coded GA to calculate the voltage phase angles, whereas the voltage magnitudes are specified resulted in reduced computation time for the solution. Then the system is restored by calculating the voltages of the load buses in terms
... Show MoreObjectives: To highlight the knowledge of Al-Kindy medical students regarding varicella infection and to assess their knowledge and attitude toward its prevention. Methodology: This descriptive cross-sectional study enrolled academic year 2020/2021 students at Al-Kindy College of Medicine from first to final year. We used an online questionnaire by Google forms to collect data, which were analyzed with SPSS 26. Results: A total of 208 students participated with 126 in the preclinical and 82 in the clinical grades. Generally, most clinical students were more aware about epidemiology, clinical manifestations, and complications of varicella infection than the preclinical students. Conclusion: Educational stage is a significant variab
... Show MoreThis study aims to establish an empirical correlation between biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) of the sewage flowing in Al-Diwaniyah wastewater treatment plant. The strength of the wastewater entering the plant varied from medium to high. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate rapid effluent assessment or optimal process control. The equations relating the percentage removal of
... Show MoreThis paper evaluates the appropriateness of ‘Power Up 5’ in Sterling schools in Iraq from the aspects of Design & Layout, Subject & Content, Activities and skills from the teachers’ perspectives. The study followed the quantitative approach where a questionnaire was adopted from a previous study which was made regarding the same objectives and research questions. Adapted from Litz (2005). The data were gathered by distributing the questionnaire to 55 English teachers in Sterling schools in Iraq through a 5 Likert scale questionnaire. The results of the analysis are generally in favour of the textbook regarding research questions and the appropriateness to Iraqi students in grade 5. The textbook can be adopted with ease in Iraqi public
... Show MoreThe aim of the present research is to illustrate γ-ray levels emitting from soil and bitumen producing from 238U, 232Th, and 40K along Abu-Jir Fault Zone. in the area extended from Al-Marj valley to Abu-Jir village using scintillometer device. Such study is important in environmental assessment to buildup data base about radioactivity. The concentration of natural radionuclides in the study area was determined to be occurring mostly in the clay minerals and organic matter. A high purity germanium spectrometer was used to detect the activity of these elements which ranged between 00.6±18.1- 1526±102, 0- 8.4±1.4, and 70.1±10.9- 328.2±73 in soil, and 28.2±5.6- 94±22.1, 0- 2.2±0.5, and 38.4±7.9- 70.1±10.9 in bitumen for 226Ra
... Show MoreWater quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their performance is evaluated usin
... Show MoreWater quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their perfor
... Show MoreBackground: This study aimed to determine the amount of fluoride in commercially available bottled drinking water in Al-Basra city, Iraq Materials and Methods: Eleven brands of bottled drinking water were obtained from supermarkets in Al-Basra city, Iraq. Five samples of 10 ml. were taking from each one of brands and the fluoride was determined by using fluoride ion selective electrode. Results: The highest fluoride concentration was present in BADIOT brand (1.174 mg/L) while the lowest was in Barakat brand (0.038 mg/L). One way ANOVA test showed a highley significant difference among different commercially branded types. Coclusions: Bottled water available in Al-Basra city contains less concentration of fluoride ion than normal values
... Show More