Preferred Language
Articles
/
bsj-1096
Effect of Hydroxyapatite Coatings on Corrosion Behavior for Biotype 316L SS Used in Orthopaedic Applications
...Show More Authors

Electrochemical corrosion of hydroxyapatite (HAP) coated performance depends on various parameters like applied potential, time, thickness and sintering temperature. Thus, the optimum parameters required for the development of stable HAP coatings was found by using electrophoretic deposition (EPD) technique. This study discusses the results obtained from open circuit potential-time measurements (OCP-time), potentiodynamic polarisation and immersion tests for all alloy samples done under varying experimental conditions, so that the optimum coating parameters can be established. The ageing studies of the coated samples were carried out by immersing them in Ringer’s solution for a period of 30 days indicates the importance of stable HAP coatings to prevent corrosion on the substrate material, so that enhancement to the biocompatibility will be increased.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Study of Corrosion Inhibition for Mild Steel in Hydrochloric Acid Solution by a new furan derivative
...Show More Authors
Abstract<p>The corrosion inhibition effect of a new furan derivative (furan-2-ylmethyl sulfanyl acetic acid furan-2-ylmethylenehydrazide) on mild steel in 1.0 M HCl was investigated using corrosion potential (ECORR) and potentiodynamic polarization. The obtained results indicated that the new furan derivative (furan-2-ylmethyl sulfanyl acetic acid furan-2-ylmethylenehydrazide) (FSFD) has a promising inhibitive effects on the corrosion of mild steel in 1.0 M HCl across all of the conditions examined. The density functional theory (DFT) study was performed on the new furan derivative (FSFD) at the B3LYP/6-311G (d, p) basis set level to explore the relation between their inhibition efficiency and molecular electro</p> ... Show More
View Publication
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Corrosion Effective of Condensed Synthetic Automotive Solution Containing Selective Organic Component Mixtures on Al-alloys
...Show More Authors

Abstract

 This work involves studying the effect of adding some selective organic component mixture on corrosion behavior of pure Al and its alloys in condensed synthetic automotive solution (CSAS) at room temperature. This mixture indicates the increasing of octane number in previous study and in this study show the increasing in corrosion resistance through the decreasing in corrosion rate values.

Electrochemical measurements were carried out by potentiostat at 3 mV/sec to estimate the corrosion parameters using  Tafel extrapolation method, in addition to cyclic polarization test to know the pitting susceptibility of materials in tested medium.

The cathodic Tafel slope

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2013
Journal Name
Political Sciences Journal
Political behavior for generations (Iraq's case study)
...Show More Authors

The topic area of that’s research dealing with values which adopted by Iraqi people since 1980, many changes and variables which make many situations and skills which the life is suitable in war and conflicts times. That’s values like traditional and ordering, traditionalism mean the conservation about values s and tradition which society adopted its. The Iraqi society suffering from many changes since 1980-2003, the consequently of that’s changes make Iraqi citizen more interested about luxury needs like clothes, while decreasing the interested about liberty of thought, beauty, show evidence of identity, and openness of mind. The processing of values changes associated with political behavior of Iraqi people which lead to weaken o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 01 2012
Journal Name
International Journal Of Innovative Computing, Information And Control
ITTP: A new transport protocol for VoIP applications
...Show More Authors

View Publication
Scopus (14)
Scopus
Publication Date
Sun Mar 29 2020
Journal Name
International Journal Of Simulation: Systems, Science &amp; Technology
A New Compact Microstrip Antenna for WSN Applications
...Show More Authors

View Publication
Crossref
Publication Date
Tue Dec 13 2022
Journal Name
Lecture Notes In Networks And Systems
Single-Bit Architecture for Low Power IoT Applications
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Chalcogenide Letters
Copper telluride thin films for gas sensing applications
...Show More Authors

Scopus (11)
Scopus
Publication Date
Tue Feb 01 2022
Journal Name
Chalcogenide Letters
Copper telluride thin films for gas sensing applications
...Show More Authors

Copper Telluride Thin films of thickness 700nm and 900nm, prepared thin films using thermal evaporation on cleaned Si substrates kept at 300K under the vacuum about (4x10-5 ) mbar. The XRD analysis and (AFM) measurements use to study structure properties. The sensitivity (S) of the fabricated sensors to NO2 and H2 was measured at room temperature. The experimental relationship between S and thickness of the sensitive film was investigated, and higher S values were recorded for thicker sensors. Results showed that the best sensitivity was attributed to the Cu2Te film of 900 nm thickness at the H2 gas.

View Publication
Crossref (10)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Surfaces And Interfaces
Corrosion performance of electrospinning nanofiber ZnO-NiO-CuO/polycaprolactone coated on mild steel in acid solution
...Show More Authors

View Publication
Scopus (41)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Optik
Optical and structural characteristics of pulsed DC magnetron sputtered Ce1- xTixOy coatings
...Show More Authors

This contribution investigates the impact of adding transition metal of Ti to CeOy samples at various concentrations referring to 0, 15.84, 24.46, 34.46, 36.23, 38.46, 45.38% and pure TiOy, correspondingly. The samples were fabricated by the magnetron sputtering technique. X-ray diffraction (XRD) configurations demonstrate the presence of α-Ce2O3 and Ce2O3 phases with increased Ti contents in the systems. X-ray photoelectron spectroscopy (XPS) experimentation confirms the purity of the S1-sample (CeO2) and the purity of the S8-sample (TiO2). Further XPS analysis reveals that Ti incorporation in the doped systems functions as a reducing agent because of the existence of α-Ce2O3 and Ce2O3 phases. Moreover, based on UV–vis spectroscopy res

... Show More